SA1 and RA Receptive Fields, Response Variability, and Population Responses Mapped with a Probe Array
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
SA1 and RA receptive fields, response variability, and population responses mapped with a probe array. Twenty-four slowly adapting type 1 (SA1) and 26 rapidly adapting (RA) cutaneous mechanoreceptive afferents in the rhesus monkey were studied with an array of independently controlled, punctate probes that covered an entire fingerpad. Each afferent had a receptive field (RF) on a single fingerpad and was studied at 73 skin sites (50 mm 2). The entire array was lowered to 1.6 mm below the point of initial skin contact (the background indentation) before delivering single-probe indentations. SA1 and RA responses differed in several ways. 1) SA1 RF boundaries were affected much less by indentation depth than were RA boundaries, and the SA1 RF areas were much more uniform in size. The mean SA1 RF area grew from 5.1 to 8.8 mm 2 as the indentation depth increased from 50 to 500 μm; the mean RA RF area grew from 5.5 to 22.4 mm 2 over the same intensity range. 2) SA1 RFs were more elongated than RA RFs. Elongated RFs were oriented in all directions relative to the skin ridges and the finger axis. 3) SA1 impulse rates were linear functions of indentation depth at all probe locations in the RF; RA responses tended toward saturation beginning at 100 μm indentation depth when the probe was over the HS. Similarities between SA1 and RA responses were that 1) both were extremely repeatable with SDs < 1 impulse per trial and 2) both had population responses (number of impulses) that were nearly linear functions of indentation depth. However, SA1s represented increasing indentation depth by increasing impulse rates in a small, relatively constant group of afferents, whereas the RAs represented increasing indentation depth predominantly by the recruitment of new afferents at a distance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johansson, R. S. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012411 · Cited by 430 · cited 3×
“Studies that appear to have taken the greatest care to map RFs at amplitudes close to threshold (Johansson 1978; Talbot et al. 1968) report small RF areas of 3–5 mm2.”
Knibestöl, M., & Vallbo, Å. B. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013160 · Cited by 181
Cited by
A sensorimotor account of vision and visual consciousness
O'Regan, J. K., & Noë, A. (2001) · Behavioral and Brain Sciences · doi:10.1017/s0140525x01000115 · Cited by 3,126
Abraira, V. E., & Ginty, D. D. (2013) · Neuron · doi:10.1016/j.neuron.2013.07.051 · Cited by 1,648
The roles and functions of cutaneous mechanoreceptors
Johnson, K. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00234-8 · Cited by 1,141
Self-citationThe mechanosensory neurons of touch and their mechanisms of activation
Handler, A., & Ginty, D. D. (2021) · Nature Reviews Neuroscience · doi:10.1038/s41583-021-00489-x · Cited by 437
Tactile Acuity is Enhanced in Blindness
Goldreich, D., & Kanics, I. M. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-08-03439.2003 · Cited by 427
Metadata
- Authors
- Vega-Bermudez, F., & Johnson, K. O.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1999-06-01
- Volume
- 81
- Issue
- 6
- Pages
- 2701-2710
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2183201923
- Cited by
- 126
- References
- 2
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.