The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Surface plasmon resonance: principles, methods and applications in biomedical sciences
Open accessAbstract
Surface plasmon resonance (SPR) is a phenomenon occuring at metal surfaces (typically gold and silver) when an incident light beam strikes the surface at a particular angle. Depending on the thickness of a molecular layer at the metal surface, the SPR phenomenon results in a graded reduction in intensity of the reflected light. Biomedical applications take advantage of the exquisite sensitivity of SPR to the refractive index of the medium next to the metal surface, which makes it possible to measure accurately the adsorption of molecules on the metal surface and their eventual interactions with specific ligands. The last ten years have seen a tremendous development of SPR use in biomedical applications. The technique is applied not only to the measurement in real‐time of the kinetics of ligand–receptor interactions and to the screening of lead compounds in the pharmaceutical industry, but also to the measurement of DNA hybridization, enzyme–substrate interactions, in polyclonal antibody characterization, epitope mapping, protein conformation studies and label‐free immunoassays. Conventional SPR is applied in specialized biosensing instruments. These instruments use expensive sensor chips of limited reuse capacity and require complex chemistry for ligand or protein immobilization. Our laboratory has successfully applied SPR with colloidal gold particles in buffered solution. This application offers many advantages over conventional SPR. The support is cheap, easily synthesized, and can be coated with various proteins or protein–ligand complexes by charge adsorption. With colloidal gold, the SPR phenomenon can be monitored in any UV‐vis spectrophotometer. For high‒throughput applications, we have adapted the technology in an automated clinical chemistry analyzer. This simple technology finds application in label‐free quantitative immunoassay techniques for proteins and small analytes, in conformational studies with proteins as well as in the real‐time association‐dissociation measurements of receptor–ligand interactions, for high‐throughput screening and lead optimization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elghanian, R., Storhoff, J. J., Mucic, R. C., Letsinger, R. L., & Mirkin, C. A. (1997) · Science · doi:10.1126/science.277.5329.1078 · Cited by 4,399
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Crystal structure of human serum albumin at 2.5 Å resolution
Sugio, S., Kashima, A., Mochizuki, S., Noda, M., & Kobayashi, K. (1999) · Protein Engineering, Design and Selection · doi:10.1093/protein/12.6.439 · Cited by 1,786
Nanosphere Lithography: Tunable Localized Surface Plasmon Resonance Spectra of Silver Nanoparticles
Jensen, T. R., Malinsky, M. D., Haynes, C. L., & Van Duyne, R. P. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp002435e · Cited by 1,260
Malinsky, M. D., Kelly, K. L., Schatz, G. C., & Van Duyne, R. P. (2001) · Journal of the American Chemical Society · doi:10.1021/ja003312a · Cited by 1,078
Quantitative Interpretation of the Response of Surface Plasmon Resonance Sensors to Adsorbed Films
Jung, L. S., Campbell, C. T., Chinowsky, T. M., Mar, M. N., & Yee, S. S. (1998) · Langmuir · doi:10.1021/la971228b · Cited by 1,012
Protein-protein interactions: methods for detection and analysis.
Phizicky, E. M., & Fields, S. (1995) · Microbiological reviews · doi:10.1128/mmbr.59.1.94-123.1995 · Cited by 966
Colloidal Au-Enhanced Surface Plasmon Resonance for Ultrasensitive Detection of DNA Hybridization
He, L., Musick, M. D., Nicewarner, S. R., Salinas, F. G., Benkovic, S. J., Natan, M. J., & Keating, C. D. (2000) · Journal of the American Chemical Society · doi:10.1021/ja001215b · Cited by 932
Nath, N., & Chilkoti, A. (2002) · Analytical Chemistry · doi:10.1021/ac015657x · Cited by 918
Effect of the Solution Refractive Index on the Color of Gold Colloids
Underwood, S., & Mulvaney, P. (1994) · Langmuir · doi:10.1021/la00022a011 · Cited by 720
Cited by
Highly sensitive graphene biosensors based on surface plasmon resonance
Wu, L., Chu, H. S., Koh, W. S., & Li, E. P. (2010) · Optics Express · doi:10.1364/oe.18.014395 · Cited by 969
Sustainable Preparation of Supported Metal Nanoparticles and Their Applications in Catalysis
Campelo, J. M., Luna, D., Luque, R., Marinas, J. M., & Romero, A. A. (2009) · ChemSusChem · doi:10.1002/cssc.200800227 · Cited by 800
Gold nanoparticle-enabled biological and chemical detection and analysis
Jans, H., & Huo, Q. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15280g · Cited by 725
The use of gold nanoparticles in diagnostics and detection
Wilson, R. (2008) · Chemical Society Reviews · doi:10.1039/b712179m · Cited by 671
Conformational changes of enzymes upon immobilisation
Secundo, F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35495d · Cited by 618
SHANKARAN, D., GOBI, K., & MIURA, N. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.09.014 · Cited by 607
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
Biosensors for cardiac biomarkers detection: A review
Qureshi, A., Gurbuz, Y., & Niazi, J. H. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.05.077 · Cited by 409
Microfluidic sample preparation: cell lysis and nucleic acid purification
Kim, J., Johnson, M., Hill, P., & Gale, B. K. (2009) · Integrative Biology · doi:10.1039/b905844c · Cited by 282
Investigations on the interface of nucleic acid aptamers and binding targets
Cai, S., Yan, J., Xiong, H., Liu, Y., Peng, D., & Liu, Z. (2018) · The Analyst · doi:10.1039/c8an01467a · Cited by 278
Stebounova, L. V., Guio, E., & Grassian, V. H. (2011) · Journal of Nanoparticle Research · doi:10.1007/s11051-010-0022-3 · Cited by 276
Advancing pharmaceutical research: A comprehensive review of cutting-edge tools and technologies
Chen, J., Lin, A., & Luo, P. (2024) · Current Pharmaceutical Analysis · doi:10.1016/j.cpan.2024.11.001 · Cited by 112
Metadata
- Authors
- Englebienne, P., Hoonacker, A. V., & Verhas, M.
- Venue
- Journal of Spectroscopy
- Publisher
- Wiley
- Published
- 2003-01
- Volume
- 17
- Issue
- 2-3
- Pages
- 255-273
- ISSN
- 2314-4920 (ISSN-L)
- 2314-4939
- OpenAlex
- W2110183864
- Cited by
- 348
- References
- 53
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.