Cited by 83Central Venous Catheters and HemodialysisVenous Thromboembolism Diagnosis and ManagementCardiac tumors and thrombi

Catheter‐Related Right Atrial Thrombus and Pulmonary Embolism: A Case Report and Systematic Review of the Literature

Open access
Burns, Karen EA, McLaren, Andrew·2009·Canadian Respiratory Journal

Abstract

Central venous catheters (CVCs) are commonly used in clinical practice. One of the foremost complications associated with their use is the potential for symptomatic or asymptomatic thrombosis. CVC thrombosis, in turn, may not only result in vascular and catheter occlusion but also infection, pulmonary embolism, and formation of right heart thromboemboli. Thrombi within cardiac chambers are associated with an increased risk of mortality due to their potential for embolization to the pulmonary vasculature. We describe the case of a 77‐year‐old man, who was successfully thrombolyzed following detection of a right atrial thrombus and hemodynamically significant pulmonary embolism resulting from thrombus formation on the tip of a peripherally inserted central catheter (PICC). The present article is the first report of a PICC‐related right atrial thrombus in an adult treated with thrombolysis. A systematic review of the literature suggests that the true incidence of this complication may be underestimated because the diagnosis may not be considered in asymptomatic and symptomatic patients, or may be missed by transthoracic echocardiography. The present case highlights the importance of maintaining a high index of suspicion for thromboembolic complications and heparin‐induced thrombocytopenia in patients with CVCs or a PICC. It also underscores the important role of transesophageal echocardiography and thrombolysis in the diagnosis and management, respectively, of right heart thromboemboli with associated pulmonary embolism.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2009/751507

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Platelet adhesion and thrombus on sensor surfaces can isolate the sensing area, cause false analytical results, and increase emboli or stroke risk.

    “However, adhesion of platelets, and eventual thrombus formation on the surface of the sensors can occur within a few hours after blood contact, and such processes can not only isolate the chemical sensing area from the bulk of the blood and lead to false analytical results but also increase the risk of emboli or stroke.8,265”
  • Platelet adhesion and thrombus formation on intravascular sensor surfaces can occur within hours after blood contact.

    “However, adhesion of platelets, and eventual thrombus formation on the surface of the sensors can occur within a few hours after blood contact, and such processes can not only isolate the chemical sensing area from the bulk of the blood and lead to false analytical results but also increase the risk of emboli or stroke.8,265”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Burns, K. E., & McLaren, A.
Affiliations
  • St. Michael's Hospital (CA)
  • London Health Sciences Centre (CA)
Corresponding author
Burns, Karen EA
Venue
Canadian Respiratory Journal
Publisher
Wiley
Published
2009-01
Volume
16
Issue
5
Pages
163-165
ISSN
  • 1198-2241 (ISSN-L)
  • 1916-7245
OpenAlex
W204439557
Cited by
83
References
8
Citations by year
2026: 3 · 2025: 1 · 2024: 4 · 2023: 8 · 2022: 6 · 2021: 9 · 2020: 5 · 2019: 6 · 2018: 7 · 2017: 8 · 2016: 6 · 2015: 6 · 2013: 4 · 2012: 3
FWCI
0.80
Type
journal article
Language
en
Open access
Locations
  • Canadian Respiratory Journal (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • TSpace (University of Toronto) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Canadian Institutes of Health Research
Topics
  • Health Sciences › Health Professions › Emergency Medical Services › Central Venous Catheters and Hemodialysis
  • Health Sciences › Medicine › Internal Medicine › Venous Thromboembolism Diagnosis and Management
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac tumors and thrombi
Keywords
catheter-related thrombosis, right atrial thrombus, pulmonary embolism, peripherally inserted central catheter, thrombolysis, transesophageal echocardiography, heparin-induced thrombocytopenia, central venous catheters
MeSH terms
Aged, Catheterization, Central Venous, Heart Atria, Heart Diseases, Humans, Male, Pulmonary Embolism, Thrombosis, Echocardiography, Transesophageal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review