A Robust and Self‐Paced BCI System Based on a Four Class SSVEP Paradigm: Algorithms and Protocols for a High‐Transfer‐Rate Direct Brain Communication
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this paper, we present, with particular focus on the adopted processing and identification chain and protocol‐related solutions, a whole self‐paced brain‐computer interface system based on a 4‐class steady‐state visual evoked potentials (SSVEPs) paradigm. The proposed system incorporates an automated spatial filtering technique centred on the common spatial patterns (CSPs) method, an autoscaled and effective signal features extraction which is used for providing an unsupervised biofeedback, and a robust self‐paced classifier based on the discriminant analysis theory. The adopted operating protocol is structured in a screening, training, and testing phase aimed at collecting user‐specific information regarding best stimulation frequencies, optimal sources identification, and overall system processing chain calibration in only a few minutes. The system, validated on 11 healthy/pathologic subjects, has proven to be reliable in terms of achievable communication speed (up to 70 bit/min) and very robust to false positive identifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“Hindawi Publishing Corporation Computational Intelligence and Neuroscience Volume 2009, Article ID 864564, 11 pages doi:10.1155/2009/864564 Research Article”
BackgroundInfluentialOptimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457 · cited 1×
“According to [15], useful information is also contained by those projections corresponding to eigenvalues close to the highest; in this specific work, we decided not to consider this information in order to minimize the feature vector dimensionality and maximize classifier robustness with small training dataset.”
BackgroundOptimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 1×
“The Bhattacharyya bound is a special case of the Chernoff bound [16, 17].”
BackgroundMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Herrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080 · cited 1×
“In this study, we used a g.EEGcap (g.Tec GmbH, AU, http://www.gtec.at/) with a set of eight gold—plated electrodes placed over the occipital area {T5,P3,Pz,P4,T5,O1,Oz,O2} with a linked-mastoids reference as illustrated in Figure 5.”
Method
Cited by
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
A Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
EEG dataset and OpenBMI toolbox for three BCI paradigms: an investigation into BCI illiteracy
Lee, M.-H., Kwon, O.-Y., Kim, Y.-J., Kim, H.-K., Lee, Y.-E., Williamson, J., Fazli, S., & Lee, S.-W. (2019) · GigaScience · doi:10.1093/gigascience/giz002 · Cited by 590
Nakanishi, M., Wang, Y., Wang, Y.-T., & Jung, T.-P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0140703 · Cited by 376
“The widely used spatial filtering methods in SSVEP-based BCIs include canonical correlation analysis (CCA) [15], minimum energy combination (MEC) [16], and common spatial pattern (CSP) [17].”
MethodIENet: a robust convolutional neural network for EEG based brain-computer interfaces
Du, Y., & Liu, J. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7257 · Cited by 34
“This idea is commonly used in other EEG processing algorithms such as canonical correlation analysis [65] and common spatial pattern [66].”
Method
Metadata
- Authors
- Parini, S., Maggi, L., Turconi, A. C., & Andreoni, G.
- Venue
- Computational Intelligence and Neuroscience
- Publisher
- Wiley
- Published
- 2009-01
- Volume
- 2009
- Issue
- 1
- Pages
- 864564-864564
- ISSN
- 1687-5265 (ISSN-L)
- 1687-5273
- OpenAlex
- W1964068569
- Cited by
- 126
- References
- 5
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Robust and Self‐Paced BCI System Based on a Four Class SSVEP Paradigm: Algorithms and Protocols for a High‐Transfer‐Rate Direct Brain Communication. https://app.cochat.ai/papers/10.1155/2009/864564
- The paper
- Parini, S., Maggi, L., Turconi, A. C., & Andreoni, G. (2009). A Robust and Self‐Paced BCI System Based on a Four Class SSVEP Paradigm: Algorithms and Protocols for a High‐Transfer‐Rate Direct Brain Communication. Computational Intelligence and Neuroscience. https://doi.org/10.1155/2009/864564
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.