Differences in the Properties of the Radial Artery between Cun , Guan , Chi , and Nearby Segments Using Ultrasonographic Imaging: A Pilot Study on Arterial Depth, Diameter, and Blood Flow
Open accessAbstract
Aim of the Study . The three conventional pulse-diagnostic palpation locations (PLs) on both wrists are Cun , Guan , and Chi , and each location reveals different clinical information. To identify anatomical or hemodynamic specificity, we used ultrasonographic imaging to determine the arterial diameter, radial artery depth, and arterial blood flow velocity at the three PLs and at nearby non-PL segments. Methods . We applied an ultrasound scanner to 44 subjects and studied the changes in the arterial diameter and depth as well as in the average/maximum blood flow velocities along the radial artery at three PLs and three non-PLs located more proximally than Chi . Results . All of the measurements at all of the PLs were significantly different ( P < 0.01). Artery depth was significantly different among the non-PLs; however, this difference became insignificant after normalization to the arm circumference. Conclusions . Substantial changes in the hemodynamic and anatomical properties of the radial artery around the three PLs were insignificant at the nearby non-PLs segments. This finding may provide a partial explanation for the diagnostic use of “ Cun , Guan , and Chi. ”
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The radial artery has an inner diameter of 2.5 mm and a wall thickness of 0.2 mm.
“The radial artery has been reported to have 2.5 mm inner diameter and 0.2 wall thickness46–48.”
From Synthetic photoplethysmography (PPG) of the radial artery through parallelized Monte Carlo and its correlation to body mass index (BMI) (2021) · cites this paper as [47]
The depth of the radial artery signal varies with obesity, from 2.5 mm for non-obese individuals at BMI of 25 to 3.5 mm for BMI of 45.
“The signal from the radial artery is discovered to vary in depth with different levels of obesity from 2.5 mm for non-obese individuals at BMI of 25 to 3.5 mm for BMI of 4547,48.”
From Synthetic photoplethysmography (PPG) of the radial artery through parallelized Monte Carlo and its correlation to body mass index (BMI) (2021) · cites this paper as [47]
Increasing obesity is associated with changes in dermal water content, dermal blood content, dermal thickness, and increased radial artery depth.
“The significant changes to the skin which we have highlighted include changes to dermal water content66 and blood content content66 as well as dermal thickness and increased radial artery depth all with increasing levels of obesity47,48,58.”
From Synthetic photoplethysmography (PPG) of the radial artery through parallelized Monte Carlo and its correlation to body mass index (BMI) (2021) · cites this paper as [47]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Drake, R. L., Vogl, A. W., & Mitchell, A. W. (2004) · Cited by 512 · see citing works
Morehouse, L. E., Miller, A. T., & Horvath, S. M. (1972) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-197200430-00004 · Cited by 246 · see citing works
Possibility of quantifying TCM finger-reading sensations: I. Bi-Sensing Pulse Diagnosis Instrument
Luo, C., Chung, Y.-F., Hu, C.-S., et al. (2012) · European Journal of Integrative Medicine · doi:10.1016/j.eujim.2012.03.003 · Cited by 79 · see citing works
Jeon, Y. J., Kim, J. U., Lee, H. J., Lee, J., Ryu, H. H., Lee, Y. J., & Kim, J. Y. (2009) · Evidence-based Complementary and Alternative Medicine · doi:10.1093/ecam/nep150 · Cited by 54 · see citing works
Self-citationNew Assessment Model of Pulse Depth Based on Sensor Displacement in Pulse Diagnostic Devices
Bae, J.-H., Jeon, Y. J., Kim, J. Y., & Kim, J. U. (2013) · Evidence-based Complementary and Alternative Medicine · doi:10.1155/2013/938641 · Cited by 41 · see citing works
Self-citationPossibility of quantifying TCM finger-reading sensations: II. An example of health standardization
Chung, Y.-F., Hu, C.-S., Luo, C., et al. (2012) · European Journal of Integrative Medicine · doi:10.1016/j.eujim.2012.03.004 · Cited by 36 · see citing works
King, E., Walsh, S., & Cobbin, D. M. (2006) · The Journal of Alternative and Complementary Medicine · doi:10.1089/acm.2006.12.445 · Cited by 17 · see citing works
A study on characteristics of radial arteries through ultrasonic waves
Lee, Y.-J., Lee, J., & Kim, J.-Y. (2008) · doi:10.1109/iembs.2008.4649696 · Cited by 16 · see citing works
Self-citationTyan, C.-C., Liang, W.-M., Shy, H.-Y., et al. (2007) · Acupuncture & Electro-Therapeutics Research · doi:10.3727/036012907815844156 · Cited by 13 · see citing works
Kim, H., Lee, J., Kim, K.-W., et al. (2007) · Cited by 11 · see citing works
Self-citationClinical Physiology Made Ridiculously Simple
Goldberg, S. R. (1995) · Medical Entomology and Zoology · Cited by 7 · see citing works
Kim, J. U., Kim, S. H., Jeon, Y. J., et al. (2009) · Cited by 6 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 2
- [2]Walsh S. King E. Pulse Diagnosis: A Clinical Guide 2008 Sydney, Australia Elsevier
- [3]Hammer L. Chinese Pulse Diagnosis: A Contemporary Approach 2001 Seattle, Wash, USA Eastland Press
Cited by
Sorted by citations
Boonya-ananta, T., Rodriguez, A. J., Ajmal, A., Du Le, V. N., Hansen, A. K., Hutcheson, J. D., & Ramella-Roman, J. C. (2021) · Scientific Reports · doi:10.1038/s41598-021-82124-4 · Cited by 70 · see citing works
- Authors
- Kim, J. U., Lee, Y. J., Lee, J., & Kim, J. Y.
- Affiliations
- Korea Institute of Oriental Medicine (KR)
- Johns Hopkins University (US)
- Corresponding author
- Kim, Jong Yeol
- Venue
- Evidence-Based Complementary and Alternative Medicine
- Publisher
- Wiley
- Published
- 2015
- Volume
- 2015
- Pages
- 1-7
- ISSN
- 1741-427X (ISSN-L)
- 1741-4288
- PMC
- PMC4339866
- OpenAlex
- W1967805960
- Cited by
- 31
- References
- 12
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 5 · 2023: 3 · 2022: 3 · 2021: 7 · 2020: 1 · 2019: 3 · 2018: 1 · 2016: 3
- FWCI
- 2.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Evidence-based Complementary and Alternative Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Korea Institute of Oriental Medicine (K15021)
- Topics
- Health Sciences › Medicine › Complementary and alternative medicine › Traditional Chinese Medicine Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- radial artery, pulse diagnosis, traditional Chinese medicine, arterial diameter, blood flow velocity, ultrasonography, hemodynamics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review