Synthetic photoplethysmography (PPG) of the radial artery through parallelized Monte Carlo and its correlation to body mass index (BMI)

Open access
Boonya-ananta, Tananant, Rodriguez, Andres J., Ajmal, Ajmal, Du Le, Vinh Nguyen, Hansen, Anders K., Hutcheson, Joshua D., Ramella-Roman, Jessica C.·2021·Scientific Reports

Published version of a preprint

Abstract

Cardiovascular disease is one of the leading causes of death in the United States and obesity significantly increases the risk of cardiovascular disease. The measurement of blood pressure (BP) is critical in monitoring and managing cardiovascular disease hence new wearable devices are being developed to make BP more accessible to physicians and patients. Several wearables utilize photoplethysmography from the wrist vasculature to derive BP assessment although many of these devices are still at the experimental stage. With the ultimate goal of supporting instrument development, we have developed a model of the photoplethysmographic waveform derived from the radial artery at the volar surface of the wrist. To do so we have utilized the relation between vessel biomechanics through Finite Element Method and Monte Carlo light transport model. The model shows similar features to that seen in PPG waveform captured using an off the shelf device. We observe the influence of body mass index on the PPG signal. A degradation the PPG signal of up to 40% in AC to DC signal ratio was thus observed.

AI snapshot

Written from the paper’s full text.

TL;DR

The paper combines finite element modeling of radial artery dilation with Monte Carlo light transport to synthesize photoplethysmography (PPG) waveforms at the wrist and study how body mass index (BMI)-related skin changes affect the signal. The model reproduces features of a commercial PPG waveform and predicts substantial AC/DC signal degradation with increasing BMI.

Key findings

  • The synthetic PPG waveform showed features similar to those captured with an off-the-shelf Nellcor Covidien PPG device, and experimental waveforms from individuals could be overlaid with the simulated waveform.
  • Isolated BMI-related physiological changes degraded the AC/DC signal ratio: trans-epidermal water loss caused a 14.0% total signal decline, dermal blood content 18.0%, dermal thickness 41.4%, and radial artery depth 32.1%.
  • Combined obesity-level waveforms showed baseline signal changes ranging from 12.7% to 54.5%; the non-obese AC/DC ratio was 8.1% versus 4.66% at the maximum modeled obesity level, a total change of 43%.
  • Increasing epidermal melanin concentration from 3% to 42% changed the AC/DC signal ratio by 17.1%.

Methods

  • The model had two parts: finite element analysis of radial artery wall dilation under internal pressure, followed by Monte Carlo light transport using an adapted MCMatlab/mcxyz framework.
  • The radial artery was modeled with 2.5 mm inner diameter, 0.2 mm wall thickness, 0.70 MPa Young’s modulus, and 130 mmHg internal pressure; the Monte Carlo geometry included epidermis, dermis, and subcutaneous tissue with the artery embedded at 2.5 mm depth.
  • Simulations modeled a commercial Nellcor Covidien PPG sensor with 660 nm and 890 nm sources, source-detector separation of 0.97 cm, collector area 0.35 cm × 0.35 cm, numerical aperture 0.866, 89 pulse positions, and 100 million to 1 billion photons per waveform. Experimental PPG was collected from four healthy volunteers for about thirty seconds, with a representative pulse used in analysis.

Limitations

  • The paper states the work is limited to detection of the radial artery and does not consider the pulsatile effect of superficial arterioles.
  • The paper states the model geometry is limited to primary skin layers and an embedded dynamic blood vessel, excluding underlying structures around the radial artery such as muscle or the radial styloid process.
  • Evident from the text: experimental validation is preliminary and small, with methods reporting four healthy volunteers while results show PPG from three individuals; the model also isolates individual BMI-related skin changes rather than simulating all physiological changes of obesity together.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s41598-021-82124-4

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

0 of 43 cited sources checked · 0 supported · 0 flagged

  • Findingown data

    Applying 0.70 MPa stiffness to the finite element model, the vessel wall shows total dilation of 0.4 mm in diameter.

    “Applying 0.70 MPa stiffness, vessel wall shows total dilation of 0.4 mm in diameter.”
    Quote in the paperSubstantial claim
  • Findingown data

    Increasing body mass index degrades the photoplethysmographic signal, with a reduction of up to 40% in the AC to DC signal ratio.

    “We observe the influence of body mass index on the PPG signal. A degradation the PPG signal of up to 40% in AC to DC signal ratio was thus observed.”
    • Also stated in: § Results · plain
      “A comparison of the AC to DC signal ratio of each waveform shows the degradation of the signal with increasing BMI.”
    Quote in the paperSubstantial claim
  • Findingown data

    The model of the photoplethysmographic waveform derived from the radial artery at the volar surface of the wrist shows similar features to a PPG waveform captured using an off-the-shelf device.

    “The model shows similar features to that seen in PPG waveform captured using an off the shelf device.”
    • Also stated in: § Results · hedged
      “Preliminary experimental data using the PPG sensor (Fig. 5) shows features similar to that seen in simulation curve.”
    Quote in the paperSubstantial claim
  • Findingown data

    The presence of obesity degrades the quality of the signal even when the vessel mechanics remain unchanged.

    “the presence of obesity degrades the quality of the signal even when the vessel mechanics remain unchanged.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Varying dermal thickness and arterial depth alone adequately represents the effect of increasing BMI/obesity on the PPG waveform.
  • Findingown data

    At the non-obese BMI of 25 kg/m2, the AC/DC signal ratio is 8.1%.

    “The non-obese BMI of 25 kg/m2, the AC/DC signal ratio is 8.1% and at the maximum level calculated the ratio is 4.66%.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Varying dermal thickness and arterial depth alone adequately represents the effect of increasing BMI/obesity on the PPG waveform.
  • May combine two claims. 16
  • Classified as probably not a substantial claim. 10
  • May combine two claims.

    Findingown data

    The generated PPG waveform for the non-obese case comprises an AC signal representing vascular pulsatility and a DC baseline signal.

    “Figure 4C shows an example of PPG waveform generated for the non-obese case. The returned signal is comprised of an AC and a DC baseline signal, where the AC signal represents the pulsatility of the vasculature.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    There is significant variation in PPG waveforms between individuals, but the shape features can be identified in all three experimentally captured cases.

    “The PPG of three different individuals was captured experimentally (Fig. 5A). There is significant variation between individuals (Fig. 5A green, red, blue), however the features of the shape can be identified in all three cases.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Findingnone given

    The advantage of using lower number of photons is the computational time for each simulation in exchange for a higher standard deviation at each point.

    “The advantage of using lower number of photons is the computational time for each simulation in exchange for a higher standard deviation at each point.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    A comparison of the waveform shows the degradation of the baseline signal as well as changes to the wave shape itself.

    “A comparison of the waveform shows the degradation of the baseline signal as well as changes to the wave shape itself.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Varying dermal thickness and arterial depth alone adequately represents the effect of increasing BMI/obesity on the PPG waveform.
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The epidermis consists of multiple sublayers with various components, including melanin and melanocytes.

    “The epidermis consists of multiple sublayers with various components, including melanin and melanocytes54.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [54] Thody, A. J. et al. Pheomelanin as well as eumelanin is present in human epidermis. J. Investig. Dermatol. 97, 340–344 (1991). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    The arterial wall is often treated as incompressible, so internal pressure changes translate to vessel wall dilation while total wall volume is conserved.

    “The arterial wall is often treated as incompressible44,51, pressure changes applied internally translates to vessel wall dilation, but the total wall volume is conserved.”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [44] Peterson, L. H., Jensen, R. E. & Parnell, J. Mechanical properties of arteries in vivo. Circ. Res. 8, 622–639 (1960). source

      Not checked in the free run.

    • cites [51] Holzapfel, G. A. & Ogden, R. W. Constitutive modelling of arteries. Proc. R. Soc. A Math. Phys. Eng. Sci. 466, 1551–1597. https://doi.org/10.1098/rspa.2010.0058 (2010). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Prior Monte Carlo light propagation studies have not attempted to capture the PPG waveform in its entirety and have focused on an idealized skin model.

    “In order to derive a better understanding of devices based on PPG, several groups have conducted light propagation models using Monte Carlo (MC) simulations29–31. Yet to our knowledge, these studies have not attempted to capture the PPG waveform in its entirety and have focused on an idealized skin model.”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [29] Marti, D., Aasbjerg, R. N., Andersen, P. E. & Hansen, A. K. MCmatlab: an open-source, user-friendly, MATLAB-integrated three-dimensional Monte Carlo light transport solver with heat diffusion and tissue damage. J. Biomed. Opt. 23, 121622 (2018). source

      Not checked in the free run.

    • cites [30] Jacques, S. & Li, T. Monte Carlo Simulations of Light Transport in 3D Heterogenous Tissues (mcxyz. c). See http://omlc.org/software/mc/mcxyz/index.html. Accessed 30.01. 2017 (2013).

      Not checked in the free run.

    • cites [31] Chatterjee, S. & Kyriacou, P. A. Monte Carlo analysis of optical interactions in reflectance and transmittance finger photoplethysmography. Sensors 19, 789 (2019). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    The radial artery has an inner diameter of 2.5 mm and a wall thickness of 0.2 mm.

    “The radial artery has been reported to have 2.5 mm inner diameter and 0.2 wall thickness46–48.”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [46] Khamdaeng, T., Luo, J., Vappou, J., Terdtoon, P. & Konofagou, E. E. Arterial stiffness identification of the human carotid artery using the stress-strain relationship in vivo. Ultrasonics 52, 402–411. https://doi.org/10.1016/j.ultras.2011.09.006 (2012). source

      Not checked in the free run.

    • cites [47] Kim, J. U., Lee, Y. J., Lee, J. & Kim, J. Y. Differences in the properties of the radial artery between Cun, Guan, Chi, and nearby segments using ultrasonographic imaging: a pilot study on arterial depth, diameter, and blood flow. Evidence Based Complement. Altern. Med. 2015 (2015). source

      Not checked in the free run.

    • cites [48] Lee, B. J., Jeon, Y. J. & Kim, J. Y. Association of obesity with anatomical and physical indices related to the radial artery in Korean adults. Eur. J. Integr. Med. 14, 22–27 (2017). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    The dermis is comprised of connective tissue along with blood vessels (capillaries and arterioles) with blood volume ratios ranging from 0.2 to 7% and water volume concentration around 65%.

    “The dermis is comprised of connective tissue along with blood vessels (capillaries and arterioles) with blood volume ratios ranging from 0.2 to 7% and water volume concentration around 65%55,56.”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [55] Jacques, S. L. Origins of tissue optical properties in the UVA, visible, and NIR regions. OSA TOPS Adv. Opt. Imaging Photon Migr. 2, 364–369 (1996). source

      Not checked in the free run.

    • cites [56] Otto, J. M. et al. Hemoglobin concentration, total hemoglobin mass and plasma volume in patients: implications for anemia. Haematologica 102, 1477–1485 (2017). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Obesity creates variations in skin physiology, including skin barrier function, epidermal changes, dermal changes, and changes to vascular and capillary recruitment function.

    “Recent studies have shown that obesity creates variations in skin physiology5,35–38. These changes include but are not limited to skin barrier function, epidermal changes, dermal changes, and changes to the vascular and capillary recruitment function.”
    Quote in the paperSubstantial claim0 of 5 sources checked
    • cites [5] Ndumele, C. E. et al. Obesity and subtypes of incident cardiovascular disease. J. Am. Heart Assoc. 5, e003921 (2016). source

      Not checked in the free run.

    • cites [35] Mori, S. et al. Characterization of skin function associated with obesity and specific correlation to local/systemic parameters in American women. Lipids Health Dis. 16, 214 (2017). source

      Not checked in the free run.

    • cites [36] Hirt, P. A., Castillo, D. E., Yosipovitch, G. & Keri, J. E. Skin changes in the obese patient. J. Am. Acad. Dermatol. 81, 1037–1057 (2019). source

      Not checked in the free run.

    • cites [37] Spinelli, L. et al. Bulk optical properties and tissue components in the female breast from multiwavelength time-resolved optical mammography. J. Biomed. Opt. 9, 1137–1143 (2004). source

      Not checked in the free run.

    • cites [38] Lanka, P. et al. Non-invasive investigation of adipose tissue by time domain diffuse optical spectroscopy. Biomed. Opt. Exp. 11, 2779–2793 (2020). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The subcutis consists of subcutaneous adipose tissue and other connective tissue.

    “The subcutis consists of subcutaneous adipose tissue and other connective tissue57.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [57] Anderson, R. R. & Parrish, J. A. The optics of human skin. J. Investig. Dermatol. 77, 13–19 (1981). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Lightly pigmented skin adults have a melanin volume fraction of 1.3-6.3%, moderately pigmented skin adults have 11-16%, and darkly pigmented skin adults have 18-43% melanin volume fraction in the epidermis.

    “Lightly pigmented skin adults have a melanin volume fraction of 1.3–6.3%, moderately pigmented skin adults have a 11–16% melanin volume fraction, and darkly pigmented skin adults have an 18–43% melanin volume fraction in the epidermis55.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [55] Jacques, S. L. Origins of tissue optical properties in the UVA, visible, and NIR regions. OSA TOPS Adv. Opt. Imaging Photon Migr. 2, 364–369 (1996). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Trans-epidermal water loss is disrupted in the obese, and as BMI increases, TEWL increases, contributing to dry skin and skin irritation.

    “Trans-epidermal water loss (TEWL) the process where water evaporates through the epidermis from the dermis is disruption in the obese36. As BMI increases so does TWEL66, and this effect directly contributed to dry skin and skin irritation often seen in the obese population.”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [36] Hirt, P. A., Castillo, D. E., Yosipovitch, G. & Keri, J. E. Skin changes in the obese patient. J. Am. Acad. Dermatol. 81, 1037–1057 (2019). source

      Not checked in the free run.

    • cites [66] Löffler, H., Aramaki, J. & Effendy, I. The influence of body mass index on skin susceptibility to sodium lauryl sulphate. Skin Res. Technol. 8, 19–22 (2002). source

      Not checked in the free run.

  • May combine two claims.

    Interpretationcitation

    This effect has been documented by other investigators68 and it may account for some of the errors experienced by dark skin individuals utilizing wearable based on PPG68-71.

    “This effect has been documented by other investigators68 and it may account for some of the errors experienced by dark skin individuals utilizing wearable based on PPG68–71.”
    Quote in the paperNot a substantial claim0 of 4 sources checked
    • cites [68] Fallow, B. A., Tarumi, T. & Tanaka, H. Influence of skin type and wavelength on light wave reflectance. J. Clin. Monit. Comput. 27, 313–317 (2013). source

      Not checked in the free run.

    • cites [69] Bent, B., Goldstein, B. A., Kibbe, W. A. & Dunn, J. P. Investigating sources of inaccuracy in wearable optical heart rate sensors. NPJ Digit. Med. 3, 1–9 (2020). source

      Not checked in the free run.

    • cites [70] Zonios, G., Bykowski, J. & Kollias, N. Skin melanin, hemoglobin, and light scattering properties can be quantitatively assessed in vivo using diffuse reflectance spectroscopy. J. Investig. Dermatol. 117, 1452–1457 (2001). source

      Not checked in the free run.

    • cites [71] Weiler, D. T., Villajuan, S. O., Edkins, L., Cleary, S. & Saleem, J. J. In Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 1292–1296 (SAGE Publications Sage CA: Los Angeles, CA).

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The thickness of human epidermis is approximately 0.10 mm.

    “The thickness of human epidermis is approximately 0.10 mm58,59.”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [58] Derraik, J. G. et al. Effects of age, gender, BMI, and anatomical site on skin thickness in children and adults with diabetes. PLoS ONE 9, e86637 (2014). source

      Not checked in the free run.

    • cites [59] Oltulu, P., Ince, B., Kökbudak, N. & Kılıç, F. Measurement of epidermis, dermis, and total skin thicknesses from six different body regions with a new ethical histometric technique. Türk Plast. Rekonstrüktif Estetik Cerrahi Dergisi (Turk J Plast Surg) 26, 56–61 (2018).

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    There is a positive correlation between BMI and lipid and total hemoglobin, and a negative correlation between BMI and water content in breast tissue.

    “Spilenlli37 et al. studies the optical properties of breast tissue and discovered a positive correlation between BMI and lipid and total hemoglobin, and a negative correlation between BMI and water content.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Spilenlli37

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Increasing obesity is associated with changes in dermal water content, dermal blood content, dermal thickness, and increased radial artery depth.

    “The significant changes to the skin which we have highlighted include changes to dermal water content66 and blood content content66 as well as dermal thickness and increased radial artery depth all with increasing levels of obesity47,48,58.”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [66] Löffler, H., Aramaki, J. & Effendy, I. The influence of body mass index on skin susceptibility to sodium lauryl sulphate. Skin Res. Technol. 8, 19–22 (2002). source

      Not checked in the free run.

    • cites [47] Kim, J. U., Lee, Y. J., Lee, J. & Kim, J. Y. Differences in the properties of the radial artery between Cun, Guan, Chi, and nearby segments using ultrasonographic imaging: a pilot study on arterial depth, diameter, and blood flow. Evidence Based Complement. Altern. Med. 2015 (2015). source

      Not checked in the free run.

    • cites [48] Lee, B. J., Jeon, Y. J. & Kim, J. Y. Association of obesity with anatomical and physical indices related to the radial artery in Korean adults. Eur. J. Integr. Med. 14, 22–27 (2017). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    The model geometry is limited to the primary layers of the skin and an embedded dynamic blood vessel, however underlying structures around the radial artery such as the muscle or radial styloid process has not been included.

    “The model geometry is limited to the primary layers of the skin and an embedded dynamic blood vessel, however underlying structures around the radial artery such as the muscle or radial styloid process has not been included.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductnone given

    This work is limited to the detection of the radial artery and does not consider the pulsatile effect of the superficial arterioles.

    “This work is limited to the detection of the radial artery and does not consider the pulsatile effect of the superficial arterioles”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductnone given

    The study protocol was approved by the Institutional Review Board of Florida International University and followed the tenets of the Declaration of Helsinki, with written informed consent obtained from subjects.

    “The protocol for the study was approved by the Institutional Review Board of Florida International University and followed the tenets of the Declaration of Helsinki. Written informed consent was obtained from the subjects after explanation of the nature and possible consequences of the study.”
    Quote in the paperNot a substantial claim
20 of 20
  • The authors state this as an assumption.

    Blood flow in the radial artery can be approximated as a Newtonian fluid and modeled as a homogeneous fluid.

    “In vessels of this size, the vessel diameter is large compared to cell size and fluid can be approximated as a Newtonian fluid25,26 and flow can be modeled as a homogenous fluid27 flow.”
  • The paper relies on this without support.

    The four physiological changes (trans-epidermal water loss, dermal blood content, dermal thickness, and radial artery depth) are the changes attributed to obesity that affect PPG.

    “Figure 6 shows changes AC/DC signal from four different changes attributed to obesity across different BMI levels.”
  • The paper relies on this without support.

    Varying dermal thickness and arterial depth alone adequately represents the effect of increasing BMI/obesity on the PPG waveform.

    “Waveforms for different levels of obesity are generated through varying the combined dermal thickness and arterial depth to indicate corresponding physiological changes.”
3 of 3

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • Maximum modeled artery depth is stated as both 3.5 and 4.5 mm

    Major

    The Methods says artery depth reaches 3.5 mm at BMI 45, whereas the Results says the obesity waveforms use depths up to 4.5 mm. It is unclear which maximum depth underlies the reported waveforms.

  • Table 3 gives radial-artery depth in centimeters rather than millimeters

    Minor

    Table 3 labels the baseline radial-artery depth as 2.5 cm, but the model description places it at 2.5 mm. These are tenfold different depths.

  • Table 3 gives dermal thickness in centimeters rather than millimeters

    Minor

    Table 3 labels its dermal-thickness values in centimeters, while the Results describes the same 1.0-to-2.5 range in millimeters. The table's units make these modeled thicknesses ten times larger.

  • Discussion gives a different simulated BMI range

    Minor

    The Discussion describes the isolated-change results as spanning BMI 20 to 40, but the simulation-parameter table spans BMI 25 to 45.

4 of 4

Cites

Flagged first, then by citations

1 of the 64 references couldn’t be matched to a known paper.

Research works printed but not linked: 4

  1. Garrow, J. S. & Webster, J. Quetelet’s index (W/H2) as a measure of fatness. Int. J. Obes. 9, 147–153 (1985).
  2. Kaplan, J. A. Kaplan’s Essentials of Cardiac Anesthesia E-Book (Elsevier Health Sciences, Amsterdam, 2017).
  3. Van de Vosse, F. & Van Dongen, M. Cardiovascular Fluid Mechanics—Lecture Notes (Faculty of Applied Physics, Faculty of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, 1998).
  4. Weiler, D. T., Villajuan, S. O., Edkins, L., Cleary, S. & Saleem, J. J. In Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 1292–1296 (SAGE Publications Sage CA: Los Angeles, CA).

Cited by

Sorted by citations

Authors
Boonya-ananta, T., Rodriguez, A. J., Ajmal, A., Du Le, V. N., Hansen, A. K., Hutcheson, J. D., & Ramella-Roman, J. C.
Affiliations
  • Florida International University (US)
  • Technical University of Denmark (DK)
Venue
Scientific Reports
Published
2021-01-28
Volume
11
Issue
1
Pages
2570-2570
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3124155372
Cited by
70
References
64
Citations by year
2026: 12 · 2025: 13 · 2024: 12 · 2023: 15 · 2022: 13 · 2021: 5
FWCI
3.41
Type
journal article
Language
en
Open access
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Florida International University Digital Commons (Florida International University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion, other-oa)
Funders
PATHS-UP, National Science Foundation, United States of America (EEC 1648451)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
photoplethysmography, radial artery, Monte Carlo light transport, body mass index, obesity, wearable blood pressure monitoring, cardiovascular disease
MeSH terms
Animals, Biomechanical Phenomena, Blood Pressure, Humans, Monte Carlo Method, Body Mass Index, Photoplethysmography, Radial Artery, Finite Element Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-09.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-09.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review