CoChat

Navigating from a Depth Image Converted into Sound

Open access

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Abstract

Background.Common manufactured depth sensors generate depth images that humans normally obtain from their eyes and hands. Various designs converting spatial data into sound have been recently proposed, speculating on their applicability as sensory substitution devices (SSDs).Objective.We tested such a design as a travel aid in a navigation task.Methods.Our portable device (MeloSee) converted 2D array of a depth image into melody in real-time. Distance from the sensor was translated into sound intensity, stereo-modulated laterally, and the pitch represented verticality. Twenty-one blindfolded young adults navigated along four different paths during two sessions separated by one-week interval. In some instances, a dual task required them to recognize a temporal pattern applied through a tactile vibrator while they navigated.Results.Participants learnt how to use the system on both new paths and on those they had already navigated from. Based on travel time and errors, performance improved from one week to the next. The dual task was achieved successfully, slightly affecting but not preventing effective navigation.Conclusions.The use of Kinect-type sensors to implement SSDs is promising, but it is restricted to indoor use and it is inefficient on too short range.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2015/543492

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 A blindfolded participant equipped with the set-up called MeloSee. The participant holds the distraction apparatus in her right hand.
Figure 1 A blindfolded participant equipped with the set-up called MeloSee. The participant holds the distraction apparatus in her right hand.CC BY · PubMed Central
Figure 2 Visual-auditory sensory substitution flowchart. The high-input information throughput is significantly reduced before being converted into sound.
Figure 2 Visual-auditory sensory substitution flowchart. The high-input information throughput is significantly reduced before being converted into sound.CC BY · PubMed Central
Figure 3 Retinal depth encoder. (a) Grayscale depth map. (b) Activity computation. (c) RF activities: the closer the object, the lighter the disc (Figure 3(b)) and the louder the sound; the farther the object, the darker the disc and the softer the sound.
Figure 3 Retinal depth encoder. (a) Grayscale depth map. (b) Activity computation. (c) RF activities: the closer the object, the lighter the disc (Figure 3(b)) and the louder the sound; the farther the object, the darker the disc and the softer the sound.CC BY · PubMed Central
Figure 4 Paths used in the experiment. Path A (left) was 22 m long and path B (right) was 19.6 m long. Squares indicate either the start or finish, depending on the route direction.
Figure 4 Paths used in the experiment. Path A (left) was 22 m long and path B (right) was 19.6 m long. Squares indicate either the start or finish, depending on the route direction.CC BY · PubMed Central
Figure 5 Navigation performance in the six experimental trials during the first and the second week sessions. Trials 11, 12, 13, and 14 are conducted on the same path and trials 21 and 22 on another one. Cognitive load was added in trials 2 2 and 1 4. Top panel (a): travel time in seconds (note that the Y-axis starts from 100 s); middle panel (b): number of contacts with the walls; bottom panel (c): number of U-turns. Error bars represent standard errors of the means. Stars indicate significant differences with ** P < 0.01; *** P < 0.001.
Figure 5 Navigation performance in the six experimental trials during the first and the second week sessions. Trials 11, 12, 13, and 14 are conducted on the same path and trials 21 and 22 on another one. Cognitive load was added in trials 2 2 and 1 4. Top panel (a): travel time in seconds (note that the Y-axis starts from 100 s); middle panel (b): number of contacts with the walls; bottom panel (c): number of U-turns. Error bars represent standard errors of the means. Stars indicate significant differences with ** P < 0.01; *** P < 0.001.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

See all 45

Metadata

Authors
Stoll, C., Palluel-Germain, R., Fristot, V., Pellerin, D., Alleysson, D., & Graff, C.
Affiliations
  • Centre National de la Recherche Scientifique (FR)
  • GIPSA-Lab (FR)
Corresponding author
Graff, Christian
Venue
Applied Bionics and Biomechanics
Publisher
Wiley
Published
2015
Volume
2015
Pages
1-9
ISSN
  • 1176-2322 (ISSN-L)
  • 1754-2103
OpenAlex
W1997819292
Cited by
45
References
35
Citations by year
2026: 1 · 2025: 4 · 2024: 2 · 2023: 3 · 2022: 4 · 2021: 7 · 2020: 6 · 2019: 5 · 2018: 5 · 2017: 4 · 2016: 1 · 2015: 3
FWCI
2.60
Type
journal article
Language
en
Open access
Locations
  • Applied Bionics and Biomechanics (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • French National Research Agency (ANR-12-JSH2-0008-01, ANR-11-LABX-0025)
  • Labex (ANR-12-JSH2-0008-01, ANR-11-LABX-0025)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Spatial Cognition and Navigation
Keywords
sensory substitution devices, auditory navigation, depth sensors, Kinect sensor, dual-task performance, tactile feedback, travel aids

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Navigating from a Depth Image Converted into Sound. https://app.cochat.ai/papers/10.1155/2015/543492
The paper
Stoll, C., Palluel-Germain, R., Fristot, V., Pellerin, D., Alleysson, D., & Graff, C. (2015). Navigating from a Depth Image Converted into Sound. Applied Bionics and Biomechanics. https://doi.org/10.1155/2015/543492

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.