Objective Ventricle Segmentation in Brain CT with Ischemic Stroke Based on Anatomical Knowledge
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Ventricle segmentation is a challenging technique for the development of detection system of ischemic stroke in computed tomography (CT), as ischemic stroke regions are adjacent to the brain ventricle with similar intensity. To address this problem, we developed an objective segmentation system of brain ventricle in CT. The intensity distribution of the ventricle was estimated based on clustering technique, connectivity, and domain knowledge, and the initial ventricle segmentation results were then obtained. To exclude the stroke regions from initial segmentation, a combined segmentation strategy was proposed, which is composed of three different schemes: (1) the largest three-dimensional (3D) connected component was considered as the ventricular region; (2) the big stroke areas were removed by the image difference methods based on searching optimal threshold values; (3) the small stroke regions were excluded by the adaptive template algorithm. The proposed method was evaluated on 50 cases of patients with ischemic stroke. The mean Dice, sensitivity, specificity, and root mean squared error were 0.9447, 0.969, 0.998, and 0.219 mm, respectively. This system can offer a desirable performance. Therefore, the proposed system is expected to bring insights into clinic research and the development of detection system of ischemic stroke in CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Previous methods [168], [169] have conducted experiments using images with a slice thickness of less than 3 mm.”
From Unbox the black-box for the medical explainable AI via multi-modal and multi-centre data fusion: a mini-review, two showcases and beyond (2022) · cites this paper as [168]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Li, C., Huang, R., Ding, Z., Gatenby, J. C., Metaxas, D. N., & Gore, J. C. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2146190 · Cited by 1,285
Review of brain MRI image segmentation methods
Balafar, M. A., Ramli, A. R., Saripan, M. I., & Mashohor, S. (2010) · Artificial Intelligence Review · doi:10.1007/s10462-010-9155-0 · Cited by 438
Wang, L., Li, C., Sun, Q., Xia, D., & Kao, C.-Y. (2009) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2009.04.010 · Cited by 405 · cited 1×
“…Equipment, Xi’an Jiaotong University, Xi’an 710054, China Correspondence should be addressed to Bingheng Lu; bhlu@xjtu.edu.cn and Jing Wang; wjwjggg@gmail.com Received 3 June 2016; Revised 23 August 2016; Accepted 15 December 2016; Published 7 February 2017 Academic Editor: Dariusz…”
Automatic segmentation of neonatal images using convex optimization and coupled level sets
Wang, L., Shi, F., Lin, W., Gilmore, J. H., & Shen, D. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.064 · Cited by 130 · cited 1×
“…Equipment, Xi’an Jiaotong University, Xi’an 710054, China Correspondence should be addressed to Bingheng Lu; bhlu@xjtu.edu.cn and Jing Wang; wjwjggg@gmail.com Received 3 June 2016; Revised 23 August 2016; Accepted 15 December 2016; Published 7 February 2017 Academic Editor: Dariusz…”
A modified fuzzy C-means classification method using a multiscale diffusion filtering scheme
Wang, H., & Fei, B. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.06.014 · Cited by 117 · cited 1×
“Several state-of-the-art methods have been proposed to segment ventricles inMRI [1], including active contour-based methods [2–4], fuzzy schemes [5, 6], and probabilitymethods [7, 8].”
Chen, W., Smith, R., Ji, S.-Y., Ward, K. R., & Najarian, K. (2009) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-9-s1-s4 · Cited by 95 · cited 1×
“developed a ventricular segmentation system by combining lowlevel segmentation and high-level template matching [13].”
A multiscale and multiblock fuzzy C-means classification method for brain MR images
Yang, X., & Fei, B. (2011) · Medical Physics · doi:10.1118/1.3584199 · Cited by 65 · cited 1×
“…University, Xi’an 710054, China Correspondence should be addressed to Bingheng Lu; bhlu@xjtu.edu.cn and Jing Wang; wjwjggg@gmail.com Received 3 June 2016; Revised 23 August 2016; Accepted 15 December 2016; Published 7 February 2017 Academic Editor: Dariusz Mrozek Copyright © 2017 Xiaohua Qian…”
BackgroundLi, X., Li, L. C., Lu, H., & Liang, Z. (2005) · Medical Physics · doi:10.1118/1.1944912 · Cited by 61
An active contour model for medical image segmentation with application to brain CT image
Qian, X., Wang, J., Guo, S., & Li, Q. (2013) · Medical Physics · doi:10.1118/1.4774359 · Cited by 59
Self-citationGupta, V., Ambrosius, W., Qian, G., Blazejewska, A. I., Kaźmierski, R., Urbanik, A., & Nowinski, W. L. (2010) · Academic Radiology · doi:10.1016/j.acra.2010.06.005 · Cited by 48
Cited by
Yang, G., Ye, Q., & Xia, J. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.07.016 · Cited by 717
“Previous meth-ods [168,169] have conducted experiments using images with a slice thickness of less than 3 mm.”
MethodDRINet for Medical Image Segmentation
Chen, L., Bentley, P., Mori, K., Misawa, K., Fujiwara, M., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2835303 · Cited by 343
“Many existing methods [24]–[32] are not robust to these problems.”
MethodAutomated Segmentation of Tissues Using CT and MRI: A Systematic Review
Lenchik, L., Heacock, L. C., Weaver, A. A., Boutin, R. D., Cook, T. S., Itri, J. N., Filippi, C. G., Gullapalli, R. P., Lee, J. T., Zagurovskaya, M., et al. (2019) · Academic Radiology · doi:10.1016/j.acra.2019.07.006 · Cited by 182
Zhang, Y., Wu, J., Liu, Y., Chen, Y., Wu, E. X., & Tang, X. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2996783 · Cited by 103
“Other than GM and WM, we also include lateral ventricle (LV) in the location prior because there are certain stroke lesions that are adjacent to the brain ventricles [32].”
BackgroundLi, M., Cheng, M., Chen, L., Hu, H.-T., Zhang, J., Ruan, S., Huang, H., Kuang, M., Lu, M., Li, W., et al. (2022) · European Radiology · doi:10.1007/s00330-022-08662-1 · Cited by 51
“org) to draw three regions of interest (ROIs) with a fixed size of 5 mm × 5 mm at the same depth of 1–2 cm underneath the liver capsule, avoiding the vascular structure [20].”
Background
Metadata
- Authors
- Qian, X., Lin, Y., Zhao, Y., Yue, X., Lu, B., & Wang, J.
- Affiliations
- Jilin University (CN)
- Carestream (United States) (US)
- Changchun University of Chinese Medicine (CN)
- Xi'an Jiaotong University (CN)
- Corresponding author
- Lu, Bingheng
- Wang, Jing
- Venue
- BioMed Research International
- Publisher
- Wiley
- Published
- 2017
- Volume
- 2017
- Pages
- 1-11
- ISSN
- 1110-7243 (ISSN-L)
- 2314-6133
- 2314-6141
- PMC
- PMC5320078
- OpenAlex
- W2587490412
- Cited by
- 21
- References
- 12
- Citations by year
- 2026: 1 · 2025: 2 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 2 · 2017: 1
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- BioMed Research International (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Brain Tumor Detection and Classification
- Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
- Keywords
- ischemic stroke detection, brain CT, anatomical knowledge, clustering
- MeSH terms
- Adult, Aged, Brain Ischemia, Cerebral Ventricles, Female, Humans, Male, Middle Aged, Radiographic Image Interpretation, Computer-Assisted, Sensitivity and Specificity, Tomography, X-Ray Computed, Reproducibility of Results, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.