Utility of Real-Time and Retrospective Continuous Glucose Monitoring in Patients with Type 2 Diabetes Mellitus: A Meta-Analysis of Randomized Controlled Trials
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
In the present study, we aimed to investigate the effects of continuous glucose monitoring (CGM) on blood glucose levels, body weight, blood pressure, and hypoglycaemia in patients with type 2 diabetes mellitus using a meta-analysis of randomized controlled trials (RCTs). A literature search was performed using MEDLINE, Cochrane Controlled Trials Registry, and ClinicalTrials.gov. RCTs using CGM in patients with type 2 diabetes mellitus were then selected. Statistical analysis included calculation of the standardized mean difference (SMD) or risk ratio and 95% confidence intervals (CIs) using a random effects model. After literature search, seven RCTs (669 patients) satisfied the eligibility criteria established herein and were included into the meta-analysis. Compared with the self-monitoring blood glucose group, the CGM group exhibited significantly lower HbA1c levels (SMD, −0.35; 95% CI, −0.59–−0.10; P=0.006) and shorter time spent with hypoglycaemia (SMD, −0.42; 95% CI, −0.70–−0.13; P=0.004). Conversely, no differences in body weight and blood pressure were observed between the groups. CGM in patients with type 2 diabetes mellitus could reduce HbA1c levels and time spent with hypoglycaemia. However, because few RCTs were included in this present study and heterogeneity was also noted, care should be taken when interpreting the results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics Notes: Detecting skewness from summary information: Table 1
Altman, D. G., & Bland, J. M. (1996) · BMJ · doi:10.1136/bmj.313.7066.1200 · Cited by 1,278
Intensive glucose control and macrovascular outcomes in type 2 diabetes
Turnbull, F. M., Abraira, C., Anderson, R. J., Byington, R. P., Chalmers, J. P., Duckworth, W. C., Evans, G. W., Gerstein, H. C., Holman, R. R., Moritz, T. E., et al. (2009) · Diabetologia · doi:10.1007/s00125-009-1470-0 · Cited by 1,189 · cited 2×
“Large-scale clinical trials have shown that strict blood glucose management contributes to the reduction of the risk for vascular complications in patients with type 2 diabetes mellitus [3, 4].”
BackgroundBeck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Effect of intensive therapy on the microvascular complications of type 1 diabetes mellitus
The Writing Team for the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group (2002) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.287.19.2563 · Cited by 941
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635 · cited 5×
“[20] showed that the RT-CGM group tended to have greater body weight than the SMBG group, the other three trials [18, 19, 23] showed no change or even a decrease in body weight.”
BackgroundMethodResultInfluentialHaak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623 · cited 5×
“Three trials regarding time spent with hypoglycaemia were included in the meta-analysis [21, 22, 24], with 181 and 104 pooled subjects in the CGM and SMBG groups, respectively.”
BackgroundMethodInfluentialDiabetes in Asia and the Pacific: Implications for the Global Epidemic
Nanditha, A., Ma, R. C. W., Ramachandran, A., Snehalatha, C., Chan, J. C. N., Chia, K. S., Shaw, J. E., & Zimmet, P. Z. (2016) · Diabetes Care · doi:10.2337/dc15-1536 · Cited by 487
Vigersky, R. A., Fonda, S. J., Chellappa, M., Walker, M. S., & Ehrhardt, N. M. (2012) · Diabetes Care · doi:10.2337/dc11-1438 · Cited by 301
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Yoo, H. J., An, H. G., Park, S. Y., Ryu, O. H., Kim, H. Y., Seo, J. A., Hong, E. G., Shin, D. H., Kim, Y. H., Kim, S. G., et al. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.06.015 · Cited by 244 · cited 2×
“The use of RT-CGM helps patients not only adjust diabetes medication dosage but also understand changes in blood glucose levels on a monitor and be conscious of lifestyle factors, such as meals and exercise, thereby ameliorating blood glucose levels [18, 21, 26].”
MethodResult
Cited by
A View Beyond HbA1c: Role of Continuous Glucose Monitoring
Chehregosha, H., Khamseh, M. E., Malek, M., Hosseinpanah, F., & Ismail-Beigi, F. (2019) · Diabetes Therapy · doi:10.1007/s13300-019-0619-1 · Cited by 235
“A recent meta-analysis of randomized controlled trials conducted on the utility of real-time and retrospective CGM in patients with type 2 DM showed that CGM in these patients could reduce HbA1c levels and time spent with hypoglycemia [31].”
MethodKarter, A. J., Parker, M. M., Moffet, H. H., Gilliam, L. K., & Dlott, R. (2021) · JAMA · doi:10.1001/jama.2021.6530 · Cited by 191
Seidu, S., Kunutsor, S. K., Ajjan, R. A., & Choudhary, P. (2024) · Diabetes Care · doi:10.2337/dc23-1520 · Cited by 124
Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
Jackson, M. A., Ahmann, A., & Shah, V. N. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0007 · Cited by 106
“Other evaluations of patient-reported outcomes have found high levels of use, good satisfaction, and a better understanding of their glucose patterns, among other benefits.(56,57) Quality of life remains a measure that is less frequently reported.”
BackgroundCastellana, M., Parisi, C., Di Molfetta, S., Di Gioia, L., Natalicchio, A., Perrini, S., Cignarelli, A., Laviola, L., & Giorgino, F. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001092 · Cited by 84
Uhl, S., Choure, A., Rouse, B., Loblack, A., & Reaven, P. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad652 · Cited by 76
Furler, J., O'Neal, D., Speight, J., Blackberry, I., Manski-Nankervis, J.-A., Thuraisingam, S., de La Rue, K., Ginnivan, L., Doyle, R., Holmes-Truscott, E., et al. (2020) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(19)30385-7 · Cited by 55
Lu, J., Ying, Z., Wang, P., Fu, M., Han, C., & Zhang, M. (2024) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15328 · Cited by 39
“Our study updated previous studies 11,19 and provide new evidence of CGM use in patients with T2DM.”
ResultSierra, J. A., Shah, M., Gill, M. S., Flores, Z., Chawla, H., Kaufman, F. R., & Vigersky, R. (2018) · Journal of Medical Economics · doi:10.1080/13696998.2017.1390474 · Cited by 38
Cowart, K., Updike, W., & Bullers, K. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0345 · Cited by 36
Kong, S.-Y., & Cho, M.-K. (2024) · Healthcare · doi:10.3390/healthcare12050571 · Cited by 36
“…that subdivides the types of CGM in glycemic control and considers the long-term effects and frequency of application of CGM. Additionally, we suggest that future studies should be undertaken to validate the effectiveness of CGM, focusing on devising methods that minimize these limitations.”
MethodSergel-Stringer, O. T., Wheeler, B. J., Styles, S. E., Boucsein, A., Lever, C. S., Paul, R. G., Sampson, R., Watson, A., & de Bock, M. I. (2024) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-024-01403-9 · Cited by 15
“Previous quantitative research has shown the statistically significant improvements these individuals can achieve with continuous glucose monitoring (CGM) technology [7–12], but there remains a paucity of qualitative evidence to support its feasibility in this large demographic.”
BackgroundResultRibeiro, R. T., Andrade, R., Nascimento do Ó, D., Lopes, A. F., & Raposo, J. F. (2021) · Nutrition, Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2020.12.024 · Cited by 13
Continuous Glucose Monitoring for Type 2 Diabetes: How Does It Compare with Type 1 Diabetes?
Beck, R. W., & Bergenstal, R. M. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0374 · Cited by 12
Practical Approaches to Continuous Glucose Monitoring in Primary Care: A UK-Based Consensus Opinion
Fernando, K., Alabraba, V., Welsh, J. B., Seidu, S., Strain, W. D., Bell, H. E., Davies, S., & Evans, M. (2025) · Diabetes Therapy · doi:10.1007/s13300-025-01706-x · Cited by 7
The Expanding Use of Continuous Glucose Monitoring in Type 2 Diabetes
Dabbagh, Z., McKee, M. D., Pirraglia, P. A., Clements, K. M., Liu, F., Amante, D. J., Shukla, P., & Gerber, B. S. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0536 · Cited by 7
“26,27 For those with T1D who have suboptimal glycemic control and require multiple insulin injections, continuous rtCGM appears cost-effective (incremental cost-effectiveness ratio [ICER] = $33,459/quality-adjusted life year [QALY] gained, with 10-day sensor use compared to SMBG in one study).”
Talaiti, M., Liao, X., Abulimiti, N., Zeng, M., & Wang, Y. (2026) · Journal of Diabetes Research · doi:10.1155/jdr/1464982
Metadata
- Authors
- Ida, S., Kaneko, R., & Murata, K.
- Venue
- Journal of Diabetes Research
- Publisher
- Wiley
- Published
- 2019-01-15
- Volume
- 2019
- Pages
- 1-10
- ISSN
- 2314-6745 (ISSN-L)
- 2314-6753
- OpenAlex
- W2911106684
- Cited by
- 86
- References
- 17
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.