Cited by 1,278Asthma and respiratory diseasesChronic Obstructive Pulmonary Disease (COPD) ResearchStatistical Methods in Epidemiology

Statistics Notes: Detecting skewness from summary information: Table 1

Open access
Altman, Douglas G, Bland, J Martin·1996·BMJ

Abstract

The measurement of airway resistance by the interrupter technique (Rint) needs standardization. Should measurements be made be during the expiratory or inspiratory phase of tidal breathing? In reported studies, the measurement of Rint has been calculated as the median or mean of a small number of values, is there an important difference? Subjects were 2.5–5.0 yrs (median 4.0 yrs) who had previous respiratory symptoms. The Rint in expiration (RintE) and inspiration (RintI) pre and postsalbutamol, the coefficient of variation (CV) of values contributing to measurements, and bronchodilator responsiveness (BDR) in both phases were compared. Measurements using median and mean were compared. RintE was higher than RintI by 4% (p<0.01). The CV of values making up RintE and RintI, and BDR measured in expiration and inspiration were similar. The median difference between means and medians of values making up measurements was 0.6% (range −6–11%). RintE has been shown to be consistently greater then RintI but the difference in this study is small. It is suggested that one or the other is chosen as the standard. In the present data the mean of a set of values contributing to a measurement was not significantly different from the median. However, the use of the median has been recommended since it is less affected by possible outlying values such as might be included by fully automated equipment.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.313.7066.1200

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • When a scale starts from the finite number zero, a standard deviation multiplied by two that is less than the mean indicates that the mean is unlikely to be an appropriate measure of the centre of the distribution.

    “when a scale starts from the finite number zero, the standard deviation, when multiplied by two, is less than the mean (as otherwise the mean is unlikely to be an appropriate measure of the centre of the distribution (Altman 1996)”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Altman, D. G., & Bland, J. M.
Affiliations
University of Oxford (GB)
Venue
BMJ
Publisher
BMJ
Published
1996-11-09
Volume
313
Issue
7066
Pages
1200.1
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W1591259115
Cited by
1,278
References
4
Citations by year
2026: 10 · 2025: 18 · 2024: 26 · 2023: 24 · 2022: 31 · 2021: 33 · 2020: 43 · 2019: 48 · 2018: 54 · 2017: 65 · 2016: 70 · 2015: 72 · 2014: 79 · 2013: 70 · 2012: 87
FWCI
5.62
Type
journal article
Language
en
Open access
Locations
  • BMJ (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Asthma and respiratory diseases
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
  • Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
Keywords
airway resistance, interrupter technique, coefficient of variation, bronchodilator responsiveness, salbutamol, pediatric respiratory symptoms, measurement standardization, skewness
MeSH terms
Analysis of Variance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review