Comparison of Auto- and Fixed-Continuous Positive Airway Pressure on Air Leak in Patients with Obstructive Sleep Apnea: Data from a Randomized Controlled Trial
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Auto-CPAP may cause sleep fragmentation due to variations in pressure and unintentional leaks. The aim of this study was to compare air leak between fixed-CPAP and auto-CPAP after 4 months of CPAP treatment. This study is an ancillary analysis of a randomized, double-blind, parallel, controlled trial over 4 months, comparing fixed- and auto-CPAP in newly diagnosed patients with OSA. The following data were extracted from the CPAP devices: mean and 90th percentile pressure, residual apnea-hypopnea index, mean CPAP use, and amount of leak. Within each arm, patients were also randomly allocated to use of one of the three different brands of devices. Since the leak was reported differently for each device, median leak value was determined for each brand and leaks were classified as “above the median” or “below the median”. Data from 269 patients were analyzed. The univariate analysis showed that tobacco consumption, CPAP level, and oronasal masks were associated with leaks above the median value but not the type of CPAP. The multivariate analysis showed that only CPAP level and oronasal masks were associated with leaks below the median. There were no differences in the types of mask used between fixed- and auto-CPAP. There was no impact of the type of CPAP on leaks or the type of interface used. We used a method based on the median leak value to standardize comparisons across devices which report leaks with different definitions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“an RCT demonstrated that APAP was not found to lower mask leak rates when compared to CPAP.1037”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [1037]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731 · cited 1×
“CPAP is the first-line treatment for moderate to severe obstructive sleep apnea (OSA) syndrome [1, 2].”
BackgroundObstructive sleep apnoea syndrome
Lévy, P., Kohler, M., McNicholas, W. T., Barbé, F., McEvoy, R. D., Somers, V. K., Lavie, L., & Pépin, J.-L. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.15 · Cited by 1,235 · cited 1×
“CPAP is the first-line treatment for moderate to severe obstructive sleep apnea (OSA) syndrome [1, 2].”
BackgroundSide Effects of Nasal Continuous Positive Airway Pressure in Sleep Apnea Syndrome
Pépin, J. L., Leger, P., Veale, D., Langevin, B., Robert, D., & Lévy, P. (1995) · Chest · doi:10.1378/chest.107.2.375 · Cited by 422 · cited 1×
“&e most frequently reported side effect of CPAP is leaks [3, 4] that cause annoyances such as mouth dryness and nose congestion [5, 6].”
BackgroundSchwab, R. J., Badr, S. M., Epstein, L. J., Gay, P. C., Gozal, D., Kohler, M., Lévy, P., Malhotra, A., Phillips, B. A., Rosen, I. M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201307-1282st · Cited by 306
The role of the nose in snoring and obstructive sleep apnoea: an update
Georgalas, C. (2011) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-010-1469-7 · Cited by 239 · cited 1×
“&is is a key factor in the persistence of mouth opening and mouth breathing under CPAP [29, 30], favoring mouth leak.”
BackgroundEffect of mouth leak on effectiveness of nasal bilevel ventilatory assistance and sleep architecture
Teschler, H., Stampa, J., Ragette, R., Konietzko, N., & Berthon-Jones, M. (1999) · European Respiratory Journal · doi:10.1183/09031936.99.14612519 · Cited by 196 · cited 1×
“In the AgirSASadom study, a large randomized controlled trial (RTC) (n� 322) that compared the impact of autoadjusting CPAP versus fixed-CPAP on blood pressure (BP) in OSA, auto-CPAP did not reduce 24 h diastolic blood pressure as efficiently as fixed-CPAP [12] &is might be due to microarousals caused by variations in…”
BackgroundWhere There Is Smoke…There Is Sleep Apnea
Krishnan, V., Dixon-Williams, S., & Thornton, J. D. (2014) · CHEST Journal · doi:10.1378/chest.14-0772 · Cited by 193
Type of Mask May Impact on Continuous Positive Airway Pressure Adherence in Apneic Patients
Borel, J. C., Tamisier, R., Dias-Domingos, S., Sapene, M., Martin, F., Stach, B., Grillet, Y., Muir, J. F., Levy, P., Series, F., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0064382 · Cited by 188 · cited 1×
“&e most frequently reported side effect of CPAP is leaks [3, 4] that cause annoyances such as mouth dryness and nose congestion [5, 6].”
BackgroundSelf-citationMouth Breathing Compromises Adherence to Nasal Continuous Positive Airway Pressure Therapy
Bachour, A., & Maasilta, P. K. (2004) · CHEST Journal · doi:10.1378/chest.126.4.1248 · Cited by 164 · cited 1×
“&e most frequently reported side effect of CPAP is leaks [3, 4] that cause annoyances such as mouth dryness and nose congestion [5, 6].”
BackgroundComparison of nose and face mask CPAP therapy for sleep apnoea
Mortimore, I. L., Whittle, A. T., & Douglas, N. J. (1998) · Thorax · doi:10.1136/thx.53.4.290 · Cited by 149
Cited by
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Treatment options in obstructive sleep apnea
Gambino, F., Zammuto, M. M., Virzì, A., Conti, G., & Bonsignore, M. R. (2022) · Internal and Emergency Medicine · doi:10.1007/s11739-022-02983-1 · Cited by 103
“Air leaks were unaffected by the type of CPAP [11], but in some studies fixed CPAP was superior to automatic CPAP in cardiovascular risk reduction [12] and preservation of renal function [13] during follow-up.”
BackgroundCarlier, S., Bruyneel, A.-V., & Bruyneel, M. (2021) · Sleep And Breathing · doi:10.1007/s11325-021-02367-3 · Cited by 14
“Nasal mask use is also associated with fewer residual apneas, fewer leaks, and lower effective pressure [26].”
BackgroundFasquel, L., Yazdani, P., Zaugg, C., Barras, A., Michotte, J.-B., Correvon, N., & Contal, O. (2022) · Respiratory Care · doi:10.4187/respcare.10065 · Cited by 15
“26 It has been observed that interfaces are the major determinant of unintentional air leak.”
Auto-adjusting positive airway pressure: the fine line between engineering and medicine
Messineo, L., White, D. P., Hete, B., Knepper, M., Berry, R. B., & Noah, W. H. (2025) · Sleep And Breathing · doi:10.1007/s11325-025-03409-w · Cited by 13
“Third, reduced leak was observed with APAP in some studies [38, 45, 57], but not all [ 39 , 41, 43, 44].”
Metadata
- Authors
- Lebret, M., Rotty, M.-C., Argento, C., Pepin, J.-L., Tamisier, R., Arbib, F., Jaffuel, D., Molinari, N., & Borel, J.-C.
- Affiliations
- Inserm (FR)
- Centre National de la Recherche Scientifique (FR)
- AGIR à dom (FR)
- HP2, INSERM U1042, Grenoble Alpes University, Grenoble, France
- Cabinet de Pneumologie, Échirolles, France
- Association pour l’Assistance et la Réhabilitation à Domicile (FR)
- Corresponding author
- Lebret, Marius
- ORCID
- Venue
- Canadian Respiratory Journal
- Publisher
- Wiley
- Published
- 2019-08-07
- Volume
- 2019
- Pages
- 1-7
- ISSN
- 1198-2241 (ISSN-L)
- 1916-7245
- PMC
- PMC6702837
- OpenAlex
- W2964514364
- Semantic Scholar
- 9ea490caa844eaa3be98a75b01eecbe8af147b5d
- Cited by
- 13
- References
- 31
- Citations by year
- 2024: 3 · 2023: 2 · 2022: 3 · 2021: 5
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Canadian Respiratory Journal (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- obstructive sleep apnea, auto-CPAP, air leakage, oronasal mask, CPAP pressure level, sleep fragmentation, residual apnea-hypopnea index
- MeSH terms
- Aged, Female, Humans, Male, Middle Aged, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Auto- and Fixed-Continuous Positive Airway Pressure on Air Leak in Patients with Obstructive Sleep Apnea: Data from a Randomized Controlled Trial. https://app.cochat.ai/papers/10.1155/2019/6310956
- The paper
- Lebret, M., Rotty, M.-C., Argento, C., Pepin, J.-L., Tamisier, R., Arbib, F., Jaffuel, D., Molinari, N., & Borel, J.-C. (2019). Comparison of Auto- and Fixed-Continuous Positive Airway Pressure on Air Leak in Patients with Obstructive Sleep Apnea: Data from a Randomized Controlled Trial. Canadian Respiratory Journal. https://doi.org/10.1155/2019/6310956
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.