CoChat

Comparison of Auto- and Fixed-Continuous Positive Airway Pressure on Air Leak in Patients with Obstructive Sleep Apnea: Data from a Randomized Controlled Trial

Open access

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

Auto-CPAP may cause sleep fragmentation due to variations in pressure and unintentional leaks. The aim of this study was to compare air leak between fixed-CPAP and auto-CPAP after 4 months of CPAP treatment. This study is an ancillary analysis of a randomized, double-blind, parallel, controlled trial over 4 months, comparing fixed- and auto-CPAP in newly diagnosed patients with OSA. The following data were extracted from the CPAP devices: mean and 90th percentile pressure, residual apnea-hypopnea index, mean CPAP use, and amount of leak. Within each arm, patients were also randomly allocated to use of one of the three different brands of devices. Since the leak was reported differently for each device, median leak value was determined for each brand and leaks were classified as “above the median” or “below the median”. Data from 269 patients were analyzed. The univariate analysis showed that tobacco consumption, CPAP level, and oronasal masks were associated with leaks above the median value but not the type of CPAP. The multivariate analysis showed that only CPAP level and oronasal masks were associated with leaks below the median. There were no differences in the types of mask used between fixed- and auto-CPAP. There was no impact of the type of CPAP on leaks or the type of interface used. We used a method based on the median leak value to standardize comparisons across devices which report leaks with different definitions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2019/6310956

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Classification of patients according to leakage reported by machines; median leak value was determined for each brand. (a) Distribution of leak magnitudes in the ResMed devices expressed as unintentional leakage (L/min) (x-axis). (b) Distribution of leak magnitudes in the Philips devices expressed as unintentional leakage (L/min) (x-axis). (c) Distribution of leak magnitudes in the WEINMANN devices expressed as unintentional leakage (L/min) (x-axis).
Figure 1 Classification of patients according to leakage reported by machines; median leak value was determined for each brand. (a) Distribution of leak magnitudes in the ResMed devices expressed as unintentional leakage (L/min) (x-axis). (b) Distribution of leak magnitudes in the Philips devices expressed as unintentional leakage (L/min) (x-axis). (c) Distribution of leak magnitudes in the WEINMANN devices expressed as unintentional leakage (L/min) (x-axis).CC BY · PubMed Central
Figure 2 Study flowchart: patients included in the analysis.
Figure 2 Study flowchart: patients included in the analysis.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 16

Metadata

Authors
Lebret, M., Rotty, M.-C., Argento, C., Pepin, J.-L., Tamisier, R., Arbib, F., Jaffuel, D., Molinari, N., & Borel, J.-C.
Affiliations
  • Inserm (FR)
  • Centre National de la Recherche Scientifique (FR)
  • AGIR à dom (FR)
  • HP2, INSERM U1042, Grenoble Alpes University, Grenoble, France
  • Cabinet de Pneumologie, Échirolles, France
  • Association pour l’Assistance et la Réhabilitation à Domicile (FR)
Corresponding author
Lebret, Marius
Venue
Canadian Respiratory Journal
Publisher
Wiley
Published
2019-08-07
Volume
2019
Pages
1-7
ISSN
  • 1198-2241 (ISSN-L)
  • 1916-7245
OpenAlex
W2964514364
Cited by
13
References
31
Citations by year
2024: 3 · 2023: 2 · 2022: 3 · 2021: 5
FWCI
1.37
Type
journal article
Language
en
Open access
Locations
  • Canadian Respiratory Journal (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
obstructive sleep apnea, auto-CPAP, air leakage, oronasal mask, CPAP pressure level, sleep fragmentation, residual apnea-hypopnea index
MeSH terms
Aged, Female, Humans, Male, Middle Aged, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.