[Retracted] Classification of Diabetes Using Photoplethysmogram (PPG) Waveform Analysis: Logistic Regression Modeling
Open accessAbstract
In this research, the photoplethysmogram (PPG) waveform analysis is utilized to develop a logistic regression‐based predictive model for the classification of diabetes. The classifier has three predictors age, b/a, and SP indices in which they achieved an overall accuracy of 92.3% in the prediction of diabetes. In this study, a total of 587 subjects were enrolled. A total of 459 subjects were used for model training and development, while the rest of the 128 subjects were used for model testing and validation. The classifier was able to diagnose 63 patients correctly as diabetes while 27 subjects were wrongly classified as nondiabetes with an accuracy of 70%. Again, the model classified 479 subjects as nondiabetes correctly while it incorrectly classified 18 subjects as diabetes with an accuracy of 96.4%. Finally, the proposed model revealed an overall predictive accuracy of 92.3% which makes it a reliable surrogate measure for diabetes classification and prediction in clinical settings.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The pulse wave has been used to classify patients as diabetic or not.
“the pulse wave has been used to classify patients as diabetic or not”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [177]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Type 2 Diabetes Mellitus: A Review of Current Trends
Olokoba, A. B., Obateru, O. A., & Olokoba, L. B. (2012) · Oman Medical Journal · doi:10.5001/omj.2012.68 · Cited by 1,338 · see citing works
Predicting Diabetes Mellitus With Machine Learning Techniques
Zou, Q., Qu, K., Luo, Y., Yin, D., Ju, Y., & Tang, H. (2018) · Frontiers in Genetics · doi:10.3389/fgene.2018.00515 · Cited by 952 · see citing works
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625 · see citing works
Polat, K., & Güneş, S. (2006) · Digital Signal Processing · doi:10.1016/j.dsp.2006.09.005 · Cited by 378 · see citing works
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A. T., Shaltis, P., McCombie, D. B., Asada, H. H., Warner, D. S., & Warner, M. A. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 365 · see citing works
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292 · see citing works
Type 2 diabetes data classification using stacked autoencoders in deep neural networks
Kannadasan, K., Edla, D. R., & Kuppili, V. (2018) · Clinical Epidemiology and Global Health · doi:10.1016/j.cegh.2018.12.004 · Cited by 174 · see citing works
Non invasive physiological measurements
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90184-3 · Cited by 119 · see citing works
Predicting Type 2 diabetes using an electronic nose-based artificial neural network analysis.
Mohamed, E. I., Linder, R., Perriello, G., Daniele, N. D., Pöppl, S. J., & LORENZO, A. D. (2002) · PubMed · Cited by 80 · see citing works
Chen, H., Tan, C., Lin, Z., et al. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.012 · Cited by 41 · see citing works
Photoplethysmogram second derivative review: Analysis and applications
Yousef, K. Q., Rubīns, U., & Alharbi, M. (2015) · Scientific Research and Essays · doi:10.5897/sre2015.6322 · Cited by 35 · see citing works
Islam, M. S., Rabbi, M. S.-E., Dobaie, A. M., & Hasan, M. K. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.05.010 · Cited by 28 · see citing works
Non-invasive Studies on Age Related Parameters Using a Blood Volume Pulse Sensor
Jayasree, V. K., Sandhya, T., & Radhakrishnan, P. (2008) · Measurement Science Review · doi:10.2478/v10048-008-0020-0 · Cited by 23 · see citing works
Qawqzeh, Y. (2019) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2019.0101212 · Cited by 16 · see citing works
Self-citationDigital Volume Pulse Analysis to Differentiate Diabetic From Non-Diabetic Subjects
Qawqzeh, Y. (2019) · Communications in Mathematics and Applications · doi:10.26713/cma.v10i4.1266 · Cited by 2 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 3
- [6]Manaswini P. Ranjit Predict the onset of diabetes disease using artificial neural network (ANN) International Journal of Computer Science & Emerging Technologies 2011 2 2 303 311
- [12]Shelley K. Shelley S. Hines R. Blitt C. Pulse oximeter waveform: photoelectric plethysmography Carol Lake 2001 Clinical Monitoring: W.B. Saunders Company 420 428
- [16]Challoner A. Photoelectric plethysmography for estimating cutaneous blood flow Non-Invasive Physiological Measurements 1979 127 1 London Academic Press 125 151
Cited by
Sorted by citations
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
Susana, E., Ramli, K., Murfi, H., & Apriantoro, N. H. (2022) · Information · doi:10.3390/info13020059 · Cited by 59 · see citing works
- Authors
- Qawqzeh, Y. K., Bajahzar, A. S., Jemmali, M., Otoom, M. M., & Thaljaoui, A.
- Affiliations
- Majmaah University (SA)
- Corresponding author
- Qawqzeh, Yousef K.
- Venue
- BioMed Research International
- Publisher
- Wiley
- Published
- 2020-01
- Volume
- 2020
- Issue
- 1
- Pages
- 3764653-3764653
- ISSN
- 1110-7243 (ISSN-L)
- 2314-6133
- 2314-6141
- PMC
- PMC7439205
- OpenAlex
- W3048779574
- Cited by
- 71
- References
- 16
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 14 · 2023: 20 · 2022: 24 · 2021: 3
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Status
- Retracted
- Update notices
- Open access
- hybrid
- doi.org
- Locations
- BioMed Research International (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Majmaah University (1439-4)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Physical Sciences › Computer Science › Signal Processing › Biometric Identification and Security
- Keywords
- diabetes classification, photoplethysmogram, logistic regression, diabetes prediction, B/A ratio, non-invasive diagnosis
- MeSH terms
- Adult, Aged, Diabetes Mellitus, Female, Humans, Male, Middle Aged, Logistic Models, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review