The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Vascular Closure Devices versus Manual Compression in Cardiac Interventional Procedures: Systematic Review and Meta-Analysis
Abstract
Backgrounds. Manual compression (MC) and vascular closure device (VCD) are two methods of vascular access site hemostasis after cardiac interventional procedures. However, there is still controversial over the use of them and a lack of comprehensive and systematic meta-analysis on this issue. Methods. Original articles comparing VCD and MC in cardiac interventional procedures were searched in PubMed, EMbase, Cochrane Library, and Web of Science through April 2022. Efficacy, safety, patient satisfaction, and other parameters were assessed between two groups. Heterogeneity among studies was evaluated by I2 index and the Cochran Q test, respectively. Publication bias was assessed using the funnel plot and Egger’s test. Results. A total of 32 studies were included after screening with inclusion and exclusion criteria (33481 patients). This meta-analysis found that VCD resulted in shorter time to hemostasis, ambulation, and discharge (p<0.00001). In terms of vascular complication risks, VCD group might be associated with a lower risk of major complications (p=0.0001), but the analysis limited to randomized controlled trials did not support this result (p=0.68). There was no significant difference in total complication rates (p=0.08) and bleeding-related complication rates (p=0.05) between the two groups. Patient satisfaction was higher in VCD group (p=0.002). Meta-regression analysis revealed no specific covariate as an influencing factor for above results (p>0.05). Conclusions. Compared with MC, the use of VCDs significantly shortens the time of hemostasis and allows earlier ambulation and discharge, meanwhile without increase in vascular complications. In addition, use of VCDs achieves higher patient satisfaction and leads cost savings for patients and institutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Postoperative hemostasis maintenance can be indirectly assessed by bleeding-related VASCs, which can serve as surrogate markers [18].”
In the citing paper
“the incidence of vascular access site complications (VASCs) remains between 5% and 12% [11,13,14,15,16,17,18,19,20,21,22].”
In the citing paper
“No statistically significant differences were observed in terms of bleeding-related VASCs between the VCD group and the MC group in a recent meta-analysis (4.0% vs. 5.2%—RR: 0.77, CI, 0.60–1.00, p = 0.05) [18].”
In the citing paper
“A current meta-analysis limited to the subgroup of randomized controlled trials highlighted a VASC rate of 8.8% for MC and 7.3% for VCD [18].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Luo, D., Wan, X., Liu, J., & Tong, T. (2018) · Statistical Methods in Medical Research · doi:10.1177/0962280216669183 · Cited by 4,066 · cited 1×
“Data of continuous variables represented by median and interquartile range (or max-and-min) were converted to mean and standard deviation to perform statistical analysis and data synthesis [22, 23].”
Research works printed but not linked: 56
- 10.1161/01.cir.102.suppl_4.iv-81 · doi:10.1161/01.cir.102.suppl_4.iv-81
- 10.1001/jama.2021.2133 · DOI
- 10.1161/CIR.0b013e3181f9b345 · DOI
- 10.1080/02841850802133386 · DOI · Paper page
- 10.1093/eurheartj/ehy452 · DOI
- 10.1016/j.jacc.2008.12.073 · DOI · Paper page
- 10.1016/j.jcin.2013.03.011 · DOI
- 10.1038/nrcardio.2012.160 · DOI
- 10.1161/CIR.0000000000001039 · DOI · Paper page
- 10.1002/ccd.21333 · DOI
- D. C. Duffin, 2001, Femoral arterial puncture management after percutaneous coronary procedures: a comparison of clinical outcomes and patient satisfaction between manual compression and two different vascular closure devices, The Journal of Invasive Cardiology, 13, 354
- 10.1002/ccd.23176 · doi:10.1002/ccd.23176
- 10.1002/ccd.1810340106 · doi:10.1002/ccd.1810340106
- 10.1001/jama.291.3.350 · DOI · Paper page
- 10.1002/1522-726x(200101)52:1<3::aid-ccd1002>3.0.co;2-g · doi:10.1002/1522-726x(200101)52:1<3::aid-ccd1002>3.0.co;2-g
- 10.1002/14651858.CD009541.pub2 · DOI
- 10.1016/j.jacc.2004.06.048 · DOI · Paper page
- 10.1016/j.jvs.2018.05.019 · doi:10.1016/j.jvs.2018.05.019
- 10.1016/j.jacc.2007.07.028 · doi:10.1016/j.jacc.2007.07.028
- 10.1371/journal.pmed.1000097 · DOI · Paper page
- 10.1186/1471-2288-14-135 · DOI · Paper page
- 10.1136/bmj.327.7414.557 · DOI · Paper page
- 10.1002/sim.1186 · DOI · Paper page
- 10.1111/j.0006-341x.2000.00455.x · DOI · Paper page
- 10.1016/0735-1097(93)90529-a · doi:10.1016/0735-1097(93)90529-a
- 10.1016/j.carrev.2018.03.007 · doi:10.1016/j.carrev.2018.03.007
- J. Hermiller, 2005, Clinical experience with a circumferential clip-based vascular closure device in diagnostic catheterization, The Journal of Invasive Cardiology, 17, 504
- 10.1002/ccd.20922 · doi:10.1002/ccd.20922
- J. B. Hermiller, 2015, A prospective, randomized, pivotal trial of a novel extravascular collagen-based closure device compared to manual compression in diagnostic and interventional patients, The Journal of Invasive Cardiology, 27, 129
- 10.4244/EIJV10I2A31 · doi:10.4244/eijv10i2a31
- 10.1186/s12872-022-02512-0 · DOI
- 10.1016/j.jacep.2019.08.013 · doi:10.1016/j.jacep.2019.08.013
- 10.1001/jama.2014.15305 · DOI · Paper page
- 10.1177/1708538120934573 · doi:10.1177/1708538120934573
- 10.1002/ccd.26991 · doi:10.1002/ccd.26991
- 10.1016/j.jcin.2009.06.006 · DOI
- 10.7150/ijms.14476 · doi:10.7150/ijms.14476
- 10.1002/ccd.22940 · doi:10.1002/ccd.22940
- 10.1016/j.ihj.2020.12.014 · DOI
- 10.7150/ijms.11343 · doi:10.7150/ijms.11343
- 10.1016/j.ancard.2014.08.009 · doi:10.1016/j.ancard.2014.08.009
- 10.1016/j.acvd.2014.11.005 · DOI
- 10.1177/1531003512442091 · doi:10.1177/1531003512442091
- 10.1177/1538574414551576 · doi:10.1177/1538574414551576
- 10.1007/s10840-021-00981-5 · DOI
- 10.1093/europace/euz004 · doi:10.1093/europace/euz004
- 10.1002/ccd.24892 · doi:10.1002/ccd.24892
- 10.1055/s-0037-1607037 · DOI
- 10.1007/s00270-015-1204-2 · DOI
- 10.1016/j.ijcha.2016.09.002 · DOI
- 10.1007/s00392-011-0313-4 · doi:10.1007/s00392-011-0313-4
- 10.1111/jjns.12221 · doi:10.1111/jjns.12221
- 10.1016/j.avsg.2019.06.031 · doi:10.1016/j.avsg.2019.06.031
- A. F. Iqtidar, 2011, Propensity matched analysis of bleeding and vascular complications associated with vascular closure devices vs standard manual compression following percutaneous coronary intervention, Connecticut Medicine, 75, 5
- L. Junquera, 2021, Secondary femoral access hemostasis during transcatheter aortic valve replacement: impact of vascular closure devices, The Journal of Invasive Cardiology, 33, E604, 10.25270/jic/20.00588 · doi:10.25270/jic/20.00588
- T. Kuno, 2021, Outcomes of vascular closure device use after transfemoral coronary intervention: insights from the EXCEL trial, The Journal of Invasive Cardiology, 33, E619, 10.25270/jic/20.00715 · doi:10.25270/jic/20.00715
Cited by
Minici, R., Serra, R., Maglia, C., Guzzardi, G., Spinetta, M., Fontana, F., Venturini, M., & Laganà, D. (2023) · Journal of Personalized Medicine · doi:10.3390/jpm13050812 · Cited by 20
Metadata
- Authors
- Pang, N., Gao, J., Zhang, B., Guo, M., Zhang, N., Sun, M., & Wang, R.
- Affiliations
- Department of Cardiology, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
- First Clinical Medical College, Shanxi Medical University, Taiyuan, Shanxi, China
- Venue
- Cardiovascular Therapeutics
- Publisher
- Wiley
- Published
- 2022-09-09
- Volume
- 2022
- Pages
- 1-18
- ISSN
- 1755-5922
- 1755-5914
- Cited by
- 32
- References
- 2
- Language
- en
- Funders
- Natural Science Foundation of Shanxi Province, China (201801D121337, 201801D121222, 82000426)
- National Natural Science Foundation of China (201801D121337, 201801D121222, 82000426)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vascular Closure Devices versus Manual Compression in Cardiac Interventional Procedures: Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.1155/2022/8569188
- The paper
- Pang, N., Gao, J., Zhang, B., Guo, M., Zhang, N., Sun, M., & Wang, R. (2022). Vascular Closure Devices versus Manual Compression in Cardiac Interventional Procedures: Systematic Review and Meta-Analysis. Cardiovascular Therapeutics. https://doi.org/10.1155/2022/8569188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.