Onset Detection in Surface Electromyographic Signals: A Systematic Comparison of Methods
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Various methods to determine the onset of the electromyographic activity which occurs in response to a stimulus have been discussed in the literature over the last decade. Due to the stochastic characteristic of the surface electromyogram (SEMG), onset detection is a challenging task, especially in weak SEMG responses. The performance of the onset detection methods were tested, mostly by comparing their automated onset estimations to the manually determined onsets found by well-trained SEMG examiners. But a systematic comparison between methods, which reveals the benefits and the drawbacks of each method compared to the other ones and shows the specific dependence of the detection accuracy on signal parameters, is still lacking. In this paper, several classical threshold-based approaches as well as some statistically optimized algorithms were tested on large samples of simulated SEMG data with well-known signal parameters. Rating between methods is performed by comparing their performance to that of a statistically optimal maximum likelihood estimator which serves as reference method. In addition, performance was evaluated on real SEMG data obtained in a reaction time experiment. Results indicate that detection behavior strongly depends on SEMG parameters, such as onset rise time, signal-to-noise ratio or background activity level. It is shown that some of the threshold-based signal-power-estimation procedures are very sensitive to signal parameters, whereas statistically optimized algorithms are generally more robust.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
The Art of Computer Programming
Whitesides, G. E. (1970) · Nuclear Science and Engineering · doi:10.13182/nse70-a19705 · Cited by 6,008
Hodges, P. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95190-5 · Cited by 983
Bonato, P., D'Alessio, T., & Knaflitz, M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661154 · Cited by 375 · cited 2×
“[14], Lidierth [15], Abbink et al.”
MethodThe Art of Computer Programming, 2nd Ed. (Addison-Wesley Series in Computer Science and Information
Knuth, D. E. (1978) · Addison-Wesley Longman Publishing Co., Inc. eBooks · Cited by 369
Objective motor response onset detection in surface myoelectric signals
Staude, G., & Wolf, W. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00067-3 · Cited by 217 · cited 6×
“As basis for comparison, some fundamental algorithmic principles formulated in [12] were used to express each method by these terms.”
BackgroundMethodResultInfluentialSelf-citationProbability density of the surface electromyogram and its relation to amplitude detectors
Clancy, E. A., & Hogan, N. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764949 · Cited by 181 · cited 1×
“The instantaneous SEMG signal energy serves as a measure of the current level of muscle activation [1], whereas the determination of the exact onset and offset times of a muscle contraction is useful in studies of motor control and performance [2, 3, 4, 5, 6, 7, 8, 9, 10].”
BackgroundDetection of EMG onset in ERP research
VAN BOXTEL, G. J. M., GERAATS, L. H. D., VAN DEN BERG‐LENSSEN, M. M. C., & BRUNIA, C. H. M. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb02062.x · Cited by 131 · cited 1×
“Although a comparison of results obtained with various approaches was presented [11, 12, 13], an objective and comprehensive assessment of their accuracy in SEMG onset detection is still lacking.”
ResultUterine EMG analysis: a dynamic approach for change detection and classification
Khalil, M. A., & Duchêne, J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.844224 · Cited by 101 · cited 1×
“Combinations of GLR-based decision rules and post-processor have been successfully applied for the detection of pre-motor silent periods in SEMG signals [22] and for the detection and classification of events in the uterine EMG [23].”
MethodBarrett, G., Shibasaki, H., & Neshige, R. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(85)90042-2 · Cited by 96 · cited 1×
“[5, 8, 18, 19]).”
Cited by
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Comparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Teager–Kaiser energy operator signal conditioning improves EMG onset detection
Solnik, S., Rider, P., Steinweg, K., DeVita, P., & Hortobágyi, T. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1521-8 · Cited by 339
Multichannel SEMG in clinical gait analysis: A review and state-of-the-art
Frigo, C., & Crenna, P. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.07.012 · Cited by 193
Burle, B., Roger, C., Allain, S., Vidal, F., & Hasbroucq, T. (2008) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2008.20110 · Cited by 163
“Indeed, although automated algorithms can be useful, visual inspection remains the most accurate technique against which all algorithms are compared ( Staude, Flachenecker, Daumer, & Wolf, 2001; van Boxtel, Geraats, van den Berg-Lessen, & Brunia, 1993), especially for detecting small changes in EMG activity such as pa…”
Method
Metadata
- Authors
- Staude, G., Flachenecker, C., Daumer, M., & Wolf, W.
- Venue
- EURASIP Journal on Advances in Signal Processing
- Published
- 2001-06-01
- Volume
- 2001
- Issue
- 2
- ISSN
- 1110-8657 (ISSN-L)
- 1687-6180
- OpenAlex
- W2071018844
- Cited by
- 211
- References
- 23
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.