The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Probability density of the surface electromyogram and its relation to amplitude detectors
Abstract
When the surface electromyogram (EMG) generated from constant-force, constant-angle, nonfatiguing contractions is modeled as a random process, its density is typically assumed to be Gaussian. This assumption leads to root-mean-square (RMS) processing as the maximum likelihood estimator of the EMG amplitude (where EMG amplitude is defined as the standard deviation of the random process). Contrary to this theoretical formulation, experimental work has found the signal-to-noise-ratio [(SNR), defined as the mean of the amplitude estimate divided by its standard deviation] using mean-absolute-value (MAV) processing to be superior to RMS. This paper reviews RMS processing with the Gaussian model and then derives the expected (inferior) SNR performance of MAV processing with the Gaussian model. Next, a new model for the surface EMG signal, using a Laplacian density, is presented. It is shown that the MAV processor is the maximum likelihood estimator of the EMG amplitude for the Laplacian model. SNR performance based on a Laplacian model is predicted to be inferior to that of the Gaussian model by approximately 32%. Thus, minor variations in the probability distribution of the EMG may result in large decrements in SNR performance. Lastly, experimental data from constant-force, constant-angle, nonfatiguing contractions were examined. The experimentally observed densities fell in between the theoretic Gaussian and Laplacian densities. On average, the Gaussian density best fit the experimental data, although results varied with subject. For amplitude estimation, MAV processing had a slightly higher SNR than RMS processing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326653 · Cited by 126
Self-citation
Cited by
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
Self-citationA myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Decoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383
A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions
Nazmi, N., Abdul Rahman, M., Yamamoto, S.-I., Ahmad, S., Zamzuri, H., & Mazlan, S. (2016) · Sensors · doi:10.3390/s16081304 · Cited by 377
Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions
Farina, D., & Merletti, R. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00025-0 · Cited by 367
Metadata
- Authors
- Clancy, E. A., & Hogan, N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999-06
- Volume
- 46
- Issue
- 6
- Pages
- 730-739
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2148146281
- Cited by
- 181
- References
- 1
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Probability density of the surface electromyogram and its relation to amplitude detectors. https://app.cochat.ai/papers/10.1109/10.764949
- The paper
- Clancy, E. A., & Hogan, N. (1999). Probability density of the surface electromyogram and its relation to amplitude detectors. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.764949
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.