In Vivo Targeting of Underglycosylated MUC-1 Tumor Antigen Using a Multimodal Imaging Probe
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
One of the most difficult challenges of oncology is to improve methods for early tumor detection, which is crucial for the success of cancer therapy and greatly improves the survival rate. Underglycosylated mucin-1 antigen (uMUC-1) is one of the early hallmarks of tumorigenesis and is overexpressed and underglycosylated on almost all human epithelial cell adenocarcinomas as well as in nonepithelial cancer cell lines, as well as in hematological malignancies such as multiple myeloma, and some B-cell non-Hodgkin lymphomas. In this study, we designed, synthesized, and tested a novel multimodal imaging probe specifically recognizing in vivo uMUC-1 antigen in an animal model of human cancer. Furthermore, in vivo magnetic resonance- and near-infrared-imaging experiments on tumor-bearing animals showed specific accumulation of the probe in uMUC-1-positive tumors and virtually no signal in control tumors. We expect that this probe has a potential to greatly aid in screening prospective patients for early cancer detection and in monitoring the efficacy of drug therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Greenlee, R. T., Murray, T., Bolden, S., & Wingo, P. A. (2000) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.50.1.7 · Cited by 3,850
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971 · cited 1×
“Thus, we believe that the results of this study could lead to the development of a versatile, clinically relevant imaging probe, particularly in view of the fact that related iron oxides have successfully been applied to clinical use (53).”
BackgroundIn vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591 · cited 1×
“For NIRF imaging, animals were treated as specified above and placed into a whole-mouse imaging system, a modification of the commercially available chemiluminescence system (Kodak), equipped with a bandpass filter at 630 nm and a long-pass filter at 700 nm (Omega Optical, Brattleboro, VT) as described previously (41).”
MethodHigh-Efficiency Intracellular Magnetic Labeling with Novel Superparamagnetic-Tat Peptide Conjugates
Josephson, L., Tung, C.-H., Moore, A., & Weissleder, R. (1999) · Bioconjugate Chemistry · doi:10.1021/bc980125h · Cited by 882
Self-citationFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827 · cited 1×
“Fluorescencemediated tomography has recently been shown to three-dimensionally localize and quantify fluorescent probes in deep tissues with high sensitivity (48).”
BackgroundIn vivo magnetic resonance imaging of transgene expression
Weissleder, R., Moore, A., Mahmood, U., Bhorade, R., Benveniste, H., Chiocca, E. A., & Basilion, J. P. (2000) · Nature Medicine · doi:10.1038/73219 · Cited by 776
Self-citationIn vivo molecular target assessment of matrix metalloproteinase inhibition
Bremer, C., Tung, C.-H., & Weissleder, R. (2001) · Nature Medicine · doi:10.1038/89126 · Cited by 726
Scaling down imaging: molecular mapping of cancer in mice
Weissleder, R. (2002) · Nature Reviews Cancer · doi:10.1038/nrc701 · Cited by 708 · cited 1×
“For example, magnetic resonance (MR) imaging can provide high spatial resolution on the order of tens of m/voxel both in small animals and in humans (33).”
BackgroundWhy are proteins O-glycosylated?
Jentoft, N. (1990) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(90)90014-3 · Cited by 705 · cited 1×
“1A), extends above the cell surface, thus interfering with the interaction between adhesion molecules on the tumor cell surface and their ligands on lymphocytes, aiding in the inaccessibility of tumor epitopes to immune recognition (23).”
BackgroundHeterogeneity of mucin gene expression in normal and neoplastic tissues.
Ho, S. B., Niehans, G. A., Lyftogt, C. T., Yan, P., Cherwitz, D. L., Gum, E. T., Dahiya, R., & Kim, Y. S. (1993) · PubMed · Cited by 665
Hough, C. D., Sherman‐Baust, C. A., Pizer, E. S., Montz, F. J., Im, D. D., Rosenshein, N. B., Cho, K. R., Riggins, G. J., & Morin, P. J. (2000) · PubMed · Cited by 548
Monocrystalline iron oxide nanocompounds (MION): Physicochemical properties
Shen, T., Weissleder, R., Papisov, M., Bogdanov, A., & Brady, T. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290504 · Cited by 499 · cited 1×
“The peptide to particle ratio was obtained from concentrations of peptide and iron, assuming 2064 iron atoms/particle (47).”
MethodTaylor-Papadimitriou, J., Burchell, J., Miles, D. W., & Dalziel, M. (1999) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/s0925-4439(99)00055-1 · Cited by 465 · cited 1×
“Because of its rod-like structure, the molecule extends 100– 200 nm above the surface, which is 5–10-fold the length of most membrane molecules (21).”
BackgroundNear-Infrared Fluorescent Nanoparticles as Combined MR/Optical Imaging Probes
Josephson, L., Kircher, M. F., Mahmood, U., Tang, Y., & Weissleder, R. (2002) · Bioconjugate Chemistry · doi:10.1021/bc015555d · Cited by 371 · cited 3×
“CLIO-NH2 was prepared as described previously (44, 46).”
BackgroundMethodIn vivo imaging of proteolytic enzyme activity using a novel molecular reporter.
Tung, C., Mahmood, U., Bredow, S., & Weissleder, R. (2000) · PubMed · Cited by 345
Tumoral Distribution of Long-circulating Dextran-coated Iron Oxide Nanoparticles in a Rodent Model
Moore, A., Marecos, E., Bogdanov, A., & Weissleder, R. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe19568 · Cited by 343 · cited 1×
“In previous studies, we have observed a similar distribution of imaging probes in tumor microenvironments (40, 51).”
BackgroundSelf-citationDelivery of Molecular Medicine to Solid Tumors
Jain, R. K. (1996) · Science · doi:10.1126/science.271.5252.1079 · Cited by 312 · cited 1×
“This possibility is in accordance with other observations of tumoral extravasation of fluorescent macromolecules (49).”
ResultNacht, M., Ferguson, A. T., Zhang, W., Petroziello, J. M., Cook, B. P., Gao, Y. H., Maguire, S., Riley, D., Coppola, G., Landes, G. M., et al. (1999) · PubMed · Cited by 272
Brossart, P., Schneider, A., Dill, P. E., Schammann, T., Grünebach, F., Wirths, S., Kanz, L., Bühring, H., & Brugger, W. (2001) · PubMed · Cited by 225
Magnetic Resonance Imaging of Inducible E-Selectin Expression in Human Endothelial Cell Culture
Kang, H. W., Josephson, L., Petrovsky, A., Weissleder, R., & Bogdanov, A. (2002) · Bioconjugate Chemistry · doi:10.1021/bc0155521 · Cited by 220
Oligosaccharides Expressed on MUC1 Produced by Pancreatic and Colon Tumor Cell Lines
Burdick, M. D., Harris, A., Reid, C. J., Iwamura, T., & Hollingsworth, M. A. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.39.24198 · Cited by 215 · cited 2×
“First, MUC-1 is overexpressed on almost all human epithelial cell adenocarcinomas, including 90% of human breast (3– 6), ovarian (5– 8), pancreatic ( 9 ), colorectal (10), lung (11, 12), prostate (13), colon (9), and gastric carcinomas (14).”
BackgroundMeasuring transferrin receptor gene expression by NMR imaging
Moore, A., Basilion, J. P., Chiocca, E. A., & Weissleder, R. (1998) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/s0167-4889(98)00002-0 · Cited by 174 · cited 1×
“Iron concentration was determined spectrophotometrically (38).”
Self-citationLewis, J. S., Achilefu, S., Garbow, J. R., Laforest, R., & Welch, M. J. (2002) · European Journal of Cancer · doi:10.1016/s0959-8049(02)00394-5 · Cited by 174
Crosslinked Iron Oxides (CLIO)
Wunderbaldinger, P., Josephson, L., & Weissleder, R. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80210-6 · Cited by 167 · cited 1×
“CLIO-NH2 was prepared as described previously (44, 46).”
MethodHuman Transferrin Receptor Gene as a Marker Gene for MR Imaging
Moore, A., Josephson, L., Bhorade, R. M., Basilion, J. P., & Weissleder, R. (2001) · Radiology · doi:10.1148/radiol.2211001784 · Cited by 156 · cited 1×
“In previous studies, we have observed a similar distribution of imaging probes in tumor microenvironments (40, 51).”
BackgroundSelf-citationMucus — a protective secretion of complexity
Allen, A. (1983) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(83)90166-4 · Cited by 148 · cited 2×
“Overall, this multimodal imaging approach, in conjunction with the chosen target, would allow for (1) early cancer detection as well as staging and imaging of the recurrence of tumors and (2) monitoring of therapeutic efficacy.”
BackgroundMethodMuc-1 Core Protein Is Expressed on Multiple Myeloma Cells and Is Induced by Dexamethasone
Treon, S. P., Mollick, J. A., Urashima, M., Teoh, G., Chauhan, D., Ogata, A., Raje, N. S., Hilgers, J., Nadler, L. M., Belch, A. R., et al. (1999) · Blood · doi:10.1182/blood.v93.4.1287 · Cited by 140
Morimura, T., Neuchrist, C., Kitz, K., Budka, H., Scheiner, O., Kraft, D., & Lassmann, H. (1990) · Acta Neuropathologica · doi:10.1007/bf00294647 · Cited by 128 · cited 1×
“Also, neoplasms are typically infiltrated by macrophages, and the degree of this infiltration can account for 20–60% of the tumor mass (50).”
BackgroundMaking the most of mucin: a novel target for tumor immunotherapy
Barratt‐Boyes, S. M. (1996) · Cancer Immunology Immunotherapy · doi:10.1007/s002620050315 · Cited by 90
Dyomin, V. G., Palanisamy, N., Lloyd, K. O., Dyomina, K., Jhanwar, S. C., Houldsworth, J., & Chaganti, R. S. K. (2000) · Blood · doi:10.1182/blood.v95.8.2666 · Cited by 89
A functionalized superparamagnetic iron oxide colloid as a receptor directed MR contrast agent
Josephson, L., Groman, E., Menz, E. T., Lewis, J. M., & Bengele, H. H. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90143-p · Cited by 88 · cited 1×
“In this study, we combined two imaging modalities that use crosslinked iron oxide (CLIO) nanoparticles as an MR-imaging contrast agent (35) and Cy5.”
MethodOosterkamp, H. M., Scheiner, L., Stefanova, M. C., Lloyd, K. O., & Finstad, C. L. (1997) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(19970703)72:1<87::aid-ijc13>3.0.co;2-7 · Cited by 78 · cited 2×
“Moreover, MUC-1 expression has been demonstrated in nonepithelial cancer cell lines [astrocytoma, melanoma, and neuroblastoma (15)], as well as in hematological malignancies such as multiple myeloma and some B-cell nonHodgkin lymphomas (16–18), in total constituting 50% of all cancers in humans (19).”
BackgroundHayes, D. F., Mesa‐Tejada, R., Papsidero, L. D., Croghan, G. A., Korzun, A. H., Norton, L., Wood, W. C., Strauchen, J. A., Grimes, M., & Weiss, R. B. (1991) · Journal of Clinical Oncology · doi:10.1200/jco.1991.9.7.1113 · Cited by 73
Ratio Imaging of Enzyme Activity Using Dual Wavelength Optical Reporters
Kircher, M. F., Josephson, L., & Weissleder, R. (2002) · Molecular Imaging · doi:10.1162/153535002320162741 · Cited by 36
Winthrop, M. D., DeNardo, S. J., & DeNardo, G. L. (1999) · PubMed · Cited by 24
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging
Veiseh, O., Gunn, J. W., & Zhang, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.002 · Cited by 1,832
Glycans in cancer and inflammation — potential for therapeutics and diagnostics
Dube, D. H., & Bertozzi, C. R. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1751 · Cited by 1,598
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Metadata
- Authors
- Moore, A., Medarova, Z., Potthast, A., & Dai, G.
- Venue
- Cancer Research
- Published
- 2004-03-01
- Volume
- 64
- Issue
- 5
- Pages
- 1821-1827
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2112519125
- Cited by
- 226
- References
- 35
- FWCI
- 7.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.