CoChat

Mistaken Identity of Widely Used Esophageal Adenocarcinoma Cell Line TE-7

Boonstra, Jurjen J., van der Velden, Albertina W., Beerens, Erwin C.W., van Marion, Ronald, Morita-Fujimura, Yuiko, Matsui, Yasuhisa, Nishihira, Tetsuro, Tselepis, Chris, Hainaut, Pierre, Lowe, Anson W., Beverloo, Berna H., van Dekken, Herman, Tilanus, Hugo W., Dinjens, Winand N.M. · 2007 · Cancer Research
Cited by 50

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Cancer of the esophagus is the seventh leading cause of cancer death worldwide. Esophageal carcinoma cell lines are useful models to study the biological and genetic alterations in these tumors. An important prerequisite of cell line research is the authenticity of the used cell lines because the mistaken identity of a cell line may lead to invalid conclusions. Estimates indicate that up to 36% of the cell lines are of a different origin or species than supposed. The TE series, established in late 1970s and early 1980s by Nishihira et al. in Japan, is one of the first esophageal cancer cell line series that was used throughout the world. Fourteen TE cell lines were derived from human esophageal squamous cell carcinomas and one, TE-7, was derived from a primary esophageal adenocarcinoma. In numerous studies, this TE-7 cell line was used as a model for esophageal adenocarcinoma because it is one of the few esophageal adenocarcinoma cell lines existing. We investigated the authenticity of the esophageal adenocarcinoma cell line TE-7 by xenografting, short tandem repeat profiling, mutation analyses, and array-comparative genomic hybridization and showed that cell line TE-7 shared the same genotype as the esophageal squamous cell carcinoma cell lines TE-2, TE-3, TE-12, and TE-13. In addition, for more than a decade, independent TE-7 cultures from Japan, United States, United Kingdom, France, and the Netherlands had the same genotype. Examination of the TE-7 cell line xenograft revealed the histology of a squamous cell carcinoma. We conclude that the TE-7 cell line, used in several laboratories throughout the world, is not an adenocarcinoma, but a squamous cell carcinoma cell line. Furthermore, the cell lines TE-2, TE-3, TE-7, TE-12, and TE-13 should be regarded as one single squamous cell carcinoma cell line. [Cancer Res 2007;67(17):7996–8001]

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1158/0008-5472.can-07-2064

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 50

Metadata

Authors
Boonstra, J. J., van der Velden, A. W., Beerens, E. C. W., van Marion, R., Morita-Fujimura, Y., Matsui, Y., Nishihira, T., Tselepis, C., Hainaut, P., Lowe, A. W., Beverloo, B. H., van Dekken, H., Tilanus, H. W., & Dinjens, W. N. M.
Venue
Cancer Research
Published
2007-09-01
Volume
67
Issue
17
Pages
7996-8001
ISSN
  • 0008-5472 (ISSN-L)
  • 1538-7445
OpenAlex
W1974048869
Cited by
50
References
3
FWCI
5.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mistaken Identity of Widely Used Esophageal Adenocarcinoma Cell Line TE-7. https://app.cochat.ai/papers/10.1158/0008-5472.can-07-2064
The paper
Boonstra, J. J., van der Velden, A. W., Beerens, E. C. W., van Marion, R., Morita-Fujimura, Y., Matsui, Y., Nishihira, T., Tselepis, C., Hainaut, P., Lowe, A. W., Beverloo, B. H., van Dekken, H., Tilanus, H. W., & Dinjens, W. N. M. (2007). Mistaken Identity of Widely Used Esophageal Adenocarcinoma Cell Line TE-7. Cancer Research. https://doi.org/10.1158/0008-5472.can-07-2064

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.