The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography
Open accessAbstract
As breast cancer screening rates increase, smaller and more numerous lesions are being identified earlier, leading to more breast-conserving surgical procedures. Achieving a clean surgical margin represents a technical challenge with important clinical implications. Optical coherence tomography (OCT) is introduced as an intraoperative high-resolution imaging technique that assesses surgical breast tumor margins by providing real-time microscopic images up to 2 mm beneath the tissue surface. In a study of 37 patients split between training and study groups, OCT images covering 1 cm2 regions were acquired from surgical margins of lumpectomy specimens, registered with ink, and correlated with corresponding histologic sections. A 17-patient training set used to establish standard imaging protocols and OCT evaluation criteria showed that areas of higher scattering tissue with a heterogeneous pattern were indicative of tumor cells and tumor tissue in contrast to lower scattering adipocytes found in normal breast tissue. The remaining 20 patients were enrolled into the feasibility study. Of these lumpectomy specimens, 11 were identified with a positive or close surgical margin and 9 were identified with a negative margin under OCT. Based on histologic findings, 9 true positives, 9 true negatives, 2 false positives, and 0 false negatives were found, yielding a sensitivity of 100% and specificity of 82%. These results show the potential of OCT as a real-time method for intraoperative margin assessment in breast-conserving surgeries. [Cancer Res 2009;69(22):8790–6]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Self-citationde Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000934 · Cited by 883
Betts, P., Mokry, B., Risser, D. R., Weiss, N. S., Williams, M. A., Sjoberg, E., Clanton, M. S., Frankel, L. S., Foxhall, L. E., Hancock, L. E., et al. (2004) · Cited by 840
Handbook of Optical Coherence Tomography
(2001) · CRC Press eBooks · doi:10.1201/b14024 · Cited by 580
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Self-citationIn vivo Margin Assessment during Partial Mastectomy Breast Surgery Using Raman Spectroscopy
Haka, A. S., Volynskaya, Z., Gardecki, J. A., Nazemi, J., Lyons, J., Hicks, D., Fitzmaurice, M., Dasari, R. R., Crowe, J. P., & Feld, M. S. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-2815 · Cited by 424
Interferometric synthetic aperture microscopy
Ralston, T. S., Marks, D. L., Scott Carney, P., & Boppart, S. A. (2007) · Nature Physics · doi:10.1038/nphys514 · Cited by 408
Self-citationIn vivo cellular optical coherence tomography imaging
Boppart, S. A., Bouma, B. E., Pitris, C., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1998) · Nature Medicine · doi:10.1038/nm0798-861 · Cited by 268
Self-citationDrezek, R., Guillaud, M., Collier, T., Boiko, I., Malpica, A., Macaulay, C., Follen, M., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528950 · Cited by 255
Cited by
Wang, Y. “., Reder, N. P., Kang, S., Glaser, A. K., Yang, Q., Wall, M. A., Javid, S. H., Dintzis, S. M., & Liu, J. T. C. (2017) · Cancer Research · doi:10.1158/0008-5472.can-17-0709 · Cited by 104
Metadata
- Authors
- Nguyen, F. T., Zysk, A. M., Chaney, E. J., Kotynek, J. G., Oliphant, U. J., Bellafiore, F. J., Rowland, K. M., Johnson, P. A., & Boppart, S. A.
- Venue
- Cancer Research
- Published
- 2009-11-11
- Volume
- 69
- Issue
- 22
- Pages
- 8790-8796
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2114022098
- Cited by
- 387
- References
- 24
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography. https://app.cochat.ai/papers/10.1158/0008-5472.can-08-4340
- The paper
- Nguyen, F. T., Zysk, A. M., Chaney, E. J., Kotynek, J. G., Oliphant, U. J., Bellafiore, F. J., Rowland, K. M., Johnson, P. A., & Boppart, S. A. (2009). Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography. Cancer Research. https://doi.org/10.1158/0008-5472.can-08-4340
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.