Real-time In Vivo Molecular Detection of Primary Tumors and Metastases with Ratiometric Activatable Cell-Penetrating Peptides
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Management of metastatic disease is integral to cancer treatment. Evaluation of metastases often requires surgical removal of all anatomically susceptible lymph nodes for ex vivo pathologic examination. We report a family of novel ratiometric activatable cell-penetrating peptides, which contain Cy5 as far red fluorescent donor and Cy7 as near-infrared fluorescent acceptor. Cy5 is quenched in favor of Cy7 re-emission until the intervening linker is cut by tumor-associated matrix metalloproteinases-2 and 9 (MMP2,9) or elastases. Such cleavage increases the Cy5:Cy7 emission ratio 40-fold and triggers tissue retention of the Cy5-containing fragment. This ratiometric increase provides an accelerated and quantifiable metric to identify primary tumors and metastases to liver and lymph nodes with increased sensitivity and specificity. This technique represents a significant advance over existing nonratiometric protease sensors and sentinel lymph node detection methods, which give no information about cancer invasion. Cancer Res; 73(2); 855–64. ©2012 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545 · cited 1×
“emission ratioing, is valuable because fluorescence imaging for clinical use (28, 29) is in its infancy and most instruments currently available in operating rooms can conduct only single fluorophore imaging.”
Tumor imaging by means of proteolytic activation of cell-penetrating peptides
Jiang, T., Olson, E. S., Nguyen, Q. T., Roy, M., Jennings, P. A., & Tsien, R. Y. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408191101 · Cited by 822 · cited 1×
“Another important advantage of RACPP is the rapidity of ratiometric change as indicator of cancer invasion, compared with the 6- and 24-hour optimal for nonratiometric ACPPs by themselves (7, 17, 21) or attached to dendrimers (9, 18), or 24 hours for commercially available dequenching probes (26).”
Self-citationIn vivo molecular target assessment of matrix metalloproteinase inhibition
Bremer, C., Tung, C.-H., & Weissleder, R. (2001) · Nature Medicine · doi:10.1038/89126 · Cited by 726 · cited 1×
“These probes primarily rely on dark quenchers such as BHQ-3 or concentrationdependent self-quenching (19, 20, 23).”
Olson, E. S., Jiang, T., Aguilera, T. A., Nguyen, Q. T., Ellies, L. G., Scadeng, M., & Tsien, R. Y. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910283107 · Cited by 567 · cited 1×
“Another important advantage of RACPP is the rapidity of ratiometric change as indicator of cancer invasion, compared with the 6- and 24-hour optimal for nonratiometric ACPPs by themselves (7, 17, 21) or attached to dendrimers (9, 18), or 24”
Self-citationBauvois, B. (2012) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2011.10.001 · Cited by 543
Nguyen, Q. T., Olson, E. S., Aguilera, T. A., Jiang, T., Scadeng, M., Ellies, L. G., & Tsien, R. Y. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910261107 · Cited by 474 · cited 2×
“Another important advantage of RACPP is the rapidity of ratiometric change as indicator of cancer invasion, compared with the 6- and 24-hour optimal for nonratiometric ACPPs by themselves (7, 17, 21) or attached to dendrimers (9, 18), or 24”
Self-citationHoshida, T., Isaka, N., Hagendoorn, J., di Tomaso, E., Chen, Y.-L., Pytowski, B., Fukumura, D., Padera, T. P., & Jain, R. K. (2006) · Cancer Research · doi:10.1158/0008-5472.can-06-1392 · Cited by 361 · cited 2×
“Cervical lymph node invasion with metastases from primary auricular tumors were generated as previously described (11).”
Calcium as a cellular regulator
Carafoli, E., & Klee, C. B. (1999) · Cited by 314
Olson, E. S., Aguilera, T. A., Jiang, T., Ellies, L. G., Nguyen, Q. T., Wong, E. H., Gross, L. A., & Tsien, R. Y. (2009) · Integrative Biology · doi:10.1039/b904890a · Cited by 263 · cited 2×
“We have previously described activatable cell-penetrating peptides (ACPP), which rely on tumor-associated MMP2,9 to unmask the adhesiveness of CPP (7, 8).”
Self-citationOptical Imaging of Matrix Metalloproteinase–2 Activity in Tumors: Feasibility Study in a Mouse Model
Bremer, C., Bredow, S., Mahmood, U., Weissleder, R., & Tung, C.-H. (2001) · Radiology · doi:10.1148/radiol.2212010368 · Cited by 255 · cited 1×
“These probes primarily rely on dark quenchers such as BHQ-3 or concentrationdependent self-quenching (19, 20, 23).”
Aguilera, T. A., Olson, E. S., Timmers, M. M., Jiang, T., & Tsien, R. Y. (2009) · Integrative Biology · doi:10.1039/b904878b · Cited by 198
Self-citationDesign, Synthesis, and Imaging of an Activatable Photoacoustic Probe
Levi, J., Kothapalli, S. R., Ma, T.-J., Hartman, K., Khuri-Yakub, B. T., & Gambhir, S. S. (2010) · Journal of the American Chemical Society · doi:10.1021/ja104000a · Cited by 177 · cited 1×
“Analogues of RACPPs have been synthesized with pheophorbide (25) or Alexa 750 (22) in place of Cy5 and”
Whitney, M., Savariar, E. N., Friedman, B., Levin, R. A., Crisp, J. L., Glasgow, H. L., Lefkowitz, R., Adams, S. R., Steinbach, P., Nashi, N., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201205721 · Cited by 102 · cited 1×
“4E–H) and thrombin (27) and should be able to report any extracellular cleavage in vivo of a linker between the polycationic and polyanionic sequences.”
Self-citationvan Duijnhoven, S. M. J., Robillard, M. S., Nicolay, K., & Grüll, H. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082503 · Cited by 102 · cited 2×
“RACPPs have also explained the claim by van Duijnhoven and colleagues (16) that ACPP targeting of tumors is due to”
Optimization of near-infrared fluorescent sentinel lymph node mapping for vulvar cancer
Hutteman, M., van der Vorst, J. R., Gaarenstroom, K. N., Peters, A. A. W., Mieog, J. S. D., Schaafsma, B. E., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. �., & Vahrmeijer, A. L. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.07.039 · Cited by 98 · cited 1×
“emission ratioing, is valuable because fluorescence imaging for clinical use (28, 29) is in its infancy and most instruments currently available in operating rooms can conduct only single fluorophore imaging.”
Development of an Orthotopic Model of Invasive Pancreatic Cancer in an Immunocompetent Murine Host
Tseng, W. W., Winer, D. A., Kenkel, J. A., Choi, O., Shain, A. H., Pollack, J. R., French, R., Lowy, A. M., & Engleman, E. G. (2010) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-09-2384 · Cited by 94 · cited 4×
“model of pancreatic cancer, LM-P (15), originally derived from liver metastases of transgenic pancreatic tumors.”
InfluentialReal-Time Video Imaging of Protease Expression In Vivo
Zhu, L., Xie, J., Swierczewska, M., Zhang, F., Quan, Q., Ma, Y., Fang, X., Kim, K., Lee, S., & Chen, X. S. (2011) · Theranostics · doi:10.7150/thno/v01p0018 · Cited by 90 · cited 1×
“These probes primarily rely on dark quenchers such as BHQ-3 or concentrationdependent self-quenching (19, 20, 23).”
Whitney, M., Crisp, J. L., Olson, E. S., Aguilera, T. A., Gross, L. A., Ellies, L. G., & Tsien, R. Y. (2010) · Journal of Biological Chemistry · doi:10.1074/jbc.m110.138297 · Cited by 74 · cited 6×
“Ratio images of RACPP3 (Fig.”
InfluentialSelf-citationChen, J., Liu, T. W. B., Lo, P., Wilson, B. C., & Zheng, G. (2009) · Bioconjugate Chemistry · doi:10.1021/bc900207k · Cited by 53 · cited 1×
“Analogues of RACPPs have been synthesized with pheophorbide (25) or Alexa 750 (22) in place of Cy5 and”
Linder, K. E., Metcalfe, E., Nanjappan, P., Arunachalam, T., Ramos, K., Skedzielewski, T., Marinelli, E. R., Tweedle, M. F., Nunn, A. D., & Swenson, R. E. (2011) · Bioconjugate Chemistry · doi:10.1021/bc100457s · Cited by 46 · cited 1×
“For example, the use of a dark quencher such as BHQ-3 has recently been shown to be problematic due to the in vivo instability of BHQ-3, leading to nonspecific dequenching within a few minutes after injection (24).”
Modern Trends in Imaging X: Spectral Imaging in Preclinical Research and Clinical Pathology
Levenson, R., Beechem, J., & McNamara, G. T. (2012) · Analytical Cellular Pathology · doi:10.1155/2012/904828 · Cited by 31
Spectral imaging in preclinical research and clinical pathology.
Levenson, R. M., Beechem, J., & McNamara, G. T. (2012) · Europe PMC (PubMed Central) · doi:10.3233/acp-2012-0062 · Cited by 21
Wittekindt, C., Jovanovic, N., & Guntinas‐Lichius, O. (2010) · Acta Oto-Laryngologica · doi:10.3109/00016489.2010.506886 · Cited by 17 · cited 1×
“IncreasedMMP2,9 expression has been shown to correlate with cancer grade (3) and decreased survival (4, 5).”
Cited by
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Fluorescence-guided surgery with live molecular navigation — a new cutting edge
Nguyen, Q. T., & Tsien, R. Y. (2013) · Nature Reviews Cancer · doi:10.1038/nrc3566 · Cited by 553
Self-citationMechanisms of drug release in nanotherapeutic delivery systems
Wong, P. T., & Choi, S. K. (2015) · Chemical Reviews · doi:10.1021/cr5004634 · Cited by 507
Beyond the margins: real-time detection of cancer using targeted fluorophores
Zhang, R. R., Schroeder, A. B., Grudzinski, J. J., Rosenthal, E. L., Warram, J. M., Pinchuk, A. N., Eliceiri, K. W., Kuo, J. S., & Weichert, J. P. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.212 · Cited by 485
Xie, J., Bi, Y., Zhang, H., Dong, S., Teng, L., Lee, R. J., & Yang, Z. (2020) · Frontiers in Pharmacology · doi:10.3389/fphar.2020.00697 · Cited by 466
Metadata
- Authors
- Savariar, E. N., Felsen, C. N., Nashi, N., Jiang, T., Ellies, L. G., Steinbach, P., Tsien, R. Y., & Nguyen, Q. T.
- Venue
- Cancer Research
- Published
- 2013-01-15
- Volume
- 73
- Issue
- 2
- Pages
- 855-864
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2002767447
- Cited by
- 159
- References
- 23
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.