Noninvasive Quantification of Solid Tumor Microstructure Using VERDICT MRI
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
There is a need for biomarkers that are useful for noninvasive imaging of tumor pathophysiology and drug efficacy. Through its use of endogenous water, diffusion-weighted MRI (DW-MRI) can be used to probe local tissue architecture and structure. However, most DW-MRI studies of cancer tissues have relied on simplistic mathematical models, such as apparent diffusion coefficient (ADC) or intravoxel incoherent motion (IVIM) models, which produce equivocal results on the relation of the model parameter estimate with the underlying tissue microstructure. Here, we present a novel technique called VERDICT (Vascular, Extracellular and Restricted Diffusion for Cytometry in Tumors) to quantify and map histologic features of tumors in vivo. VERDICT couples DW-MRI to a mathematical model of tumor tissue to access features such as cell size, vascular volume fraction, intra- and extracellular volume fractions, and pseudo-diffusivity associated with blood flow. To illustrate VERDICT, we used two tumor xenograft models of colorectal cancer with different cellular and vascular phenotypes. Our experiments visualized known differences in the tissue microstructure of each model and the significant decrease in cell volume resulting from administration of the cytotoxic drug gemcitabine, reflecting the apoptotic volume decrease. In contrast, the standard ADC and IVIM models failed to detect either of these differences. Our results illustrate the superior features of VERDICT for cancer imaging, establishing it as a noninvasive method to monitor and stratify treatment responses. Cancer Res; 74(7); 1902–12. ©2014 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 2×
“However, anisotropic versions of the ADC model [the diffusion tensor model (21)] and the IVIMmodel (a two-tensor model), as well as an isotropic version of VERDICT (with an isotropic vascular compartment), are also inferior to the VERDICT model (Supplementary Fig.”
MethodNODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Self-citationAxcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 2×
“It may be possible to estimate pore-size distributions, as in (6, 8) with sufficient SNR, e.”
BackgroundOrientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683 · cited 10×
“The standard PGSE sequence with a gradient strength of 60 mT/m is sensitive to pore sizes with diameters of 5 to 25mm(35, 36), although smaller pores are still detectable but can be identified only as "small" rather than sized accurately (7, 35).”
BackgroundSelf-citationAn analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501 · cited 1×
“For example, it maybe possible to estimate permeability or exchange time parameters via stimulated echo measurements, as in (37), or double pulsed-field gradient (dPFG) measurements, as in (38).”
BackgroundCompartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422 · cited 1×
“Model fitting VERDICT uses a similar iterative optimization procedure (8) for model fitting that accounts for local minima and Rician noise.”
MethodSelf-citation
Cited by
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Self-citationMechanisms and impact of altered tumour mechanics
Mohammadi, H., & Sahai, E. (2018) · Nature Cell Biology · doi:10.1038/s41556-018-0131-2 · Cited by 336
Panagiotaki, E., Chan, R. W., Dikaios, N., Ahmed, H. U., O’Callaghan, J., Freeman, A., Atkinson, D., Punwani, S., Hawkes, D. J., & Alexander, D. C. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000115 · Cited by 184
“The biexponential model has also been shown elsewhere in literature to have a variable performance.(20,23,37) The parametric maps from voxel-by-voxel fitting in Figure 7 reflect the trends seen in the whole-ROI fitting in Figure 4.”
BackgroundMethodSelf-citationJones, D. K., Alexander, D. C., Bowtell, R., Cercignani, M., Dell'Acqua, F., McHugh, D. J., Miller, K. L., Palombo, M., Parker, G. J. M., Rudrapatna, U. S., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.047 · Cited by 183
“proaches such as VERDICT (Panagiotaki et al., 2014) offer the promise of greater specificity of signal characterisation in terms of the relative contribution of different cellular architecture and vasculature.”
InfluentialSelf-citationIn vivo imaging of cancer cell size and cellularity using temporal diffusion spectroscopy
Jiang, X., Li, H., Xie, J., McKinley, E. T., Zhao, P., Gore, J. C., & Xu, J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26356 · Cited by 161
Metadata
- Authors
- Panagiotaki, E., Walker-Samuel, S., Siow, B., Johnson, S. P., Rajkumar, V., Pedley, R. B., Lythgoe, M. F., & Alexander, D. C.
- Venue
- Cancer Research
- Published
- 2014-03-31
- Volume
- 74
- Issue
- 7
- Pages
- 1902-1912
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2070546949
- Cited by
- 251
- References
- 7
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.