Preparation and Biological Evaluation of Copper-64–Labeled Tyr3-Octreotate Using a Cross-Bridged Macrocyclic Chelator
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Purpose: Somatostatin receptors (SSTr) are expressed on many neuroendocrine tumors, and several radiotracers have been developed for imaging these types of tumors. For this reason, peptide analogues of somatostatin have been well characterized. Copper-64 (t1/2 = 12.7 hours), a positron emitter suitable for positron emission tomography (PET) imaging, was shown recently to have improved in vivo clearance properties when chelated by the cross-bridged tetraazamacrocycle 4,11-bis(carboxymethyl)-1,4,8,11-tetraazabicyclo(6.6.2)hexadecane (CB-TE2A) compared with 1,4,8,11-tetraazacyclotetradecane-1,4,8,11-tetraacetic acid (TETA). Experimental Design: CB-TE2A and TETA were conjugated to the somatostatin analogue tyrosine-3-octreotate (Y3-TATE) for evaluation of CB-TE2A as a bifunctional chelator of 64Cu. The in vitro affinity of each compound for SSTr was determined using a homologous competitive binding assay. In vivo characteristics of both radiolabeled compounds were examined in biodistribution and microPET studies of AR42J tumor-bearing rats. Results: Cu-CB-TE2A-Y3-TATE (Kd = 1.7 nmol/L) and Cu-TETA-Y3-TATE (Kd = 0.7 nmol/L) showed similar affinities for AR42J derived SSTr. In biodistribution studies, nonspecific uptake in blood and liver was lower for 64Cu-CB-TE2A-Y3-TATE. Differences increased with time such that, at 4 hours, blood uptake was 4.3-fold higher and liver uptake was 2.4-fold higher for 64Cu-TETA-Y3-TATE than for 64Cu-CB-TE2A-Y3-TATE. In addition, 4.4-times greater tumor uptake was detected with 64Cu-CB-TE2A-Y3-TATE than with 64Cu-TETA-Y3-TATE at 4 hours postinjection. MicroPET imaging yielded similar results. Conclusions: CB-TE2A appears to be a superior in vivo bifunctional chelator of 64Cu for use in molecular imaging by PET or targeted radiotherapy due to both improved nontarget organ clearance and higher target organ uptake of 64Cu-CB-TE2A-Y3-TATE compared with 64Cu-TETA-Y3-TATE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reubi, J. C., Schär, J.-C., Waser, B., Wenger, S., Heppeler, A., Schmitt, J. S., & Mäcke, H. R. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050034 · Cited by 1,127 · cited 1×
“(39) demonstrated that relatively small changes in a”
BackgroundHofmann, M., Maecke, H., Börner, A., Weckesser, E., Schöffski, P., Oei, M., Schumacher, J., Henze, M., Heppeler, A., Meyer, G., et al. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100639 · Cited by 544
Efficient production of high specific activity 64Cu using a biomedical cyclotron
McCarthy, D. W., Shefer, R. E., Klinkowstein, R. E., Bass, L. A., Margeneau, W. H., Cutler, C. S., Anderson, C. J., & Welch, M. J. (1997) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(96)00157-6 · Cited by 533 · cited 2×
“4%, E max 656 keV) and minus ( ; 39%, E max 573 keV) emitter and can be produced in high specific activity on a small biomedical cyclotron (13, 14).”
BackgroundMethodSelf-citationBoswell, C. A., Sun, X., Niu, W., Weisman, G. R., Wong, E. H., Rheingold, A. L., & Anderson, C. J. (2004) · Journal of Medicinal Chemistry · doi:10.1021/jm030383m · Cited by 483 · cited 3×
“The cross-bridged cyclam, CB-TE2A, has demonstrated improved in vitro kinetic stability as well as a reduction of in vivo transchelation (25, 27, 38).”
BackgroundMethodSelf-citationIn Vivo Transchelation of Copper-64 from TETA-Octreotide to Superoxide Dismutase in Rat Liver
Bass, L. A., Wang, M., Welch, M. J., & Anderson, C. J. (2000) · Bioconjugate Chemistry · doi:10.1021/bc990167l · Cited by 311 · cited 3×
“Higher blood and liver uptake and increasing marrow uptake suggest that (64)Cu dissociates from the TETA peptide conjugate to a greater extent than from the CB-TE2A peptide conjugate in vivo (21).”
BackgroundSelf-citationBodei, L., Cremonesi, M., Zoboli, S., Grana, C., Bartolomei, M., Rocca, P., Caracciolo, M., Mäcke, H. R., Chinol, M., & Paganelli, G. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1023-y · Cited by 305
64Cu-TETA-octreotide as a PET imaging agent for patients with neuroendocrine tumors.
Anderson, C. J., Dehdashti, F., Cutler, P. D., Schwarz, S. W., Laforest, R. A., Bass, L. A., Lewis, J. S., & Mccarthy, D. W. (2001) · PubMed · Cited by 273
Self-citationHenze, M., Schuhmacher, J., Hipp, P., Kowalski, J., Becker, D. W., Doll, J., Mäcke, H. R., Hofmann, M., Debus, J., & Haberkorn, U. (2001) · PubMed · Cited by 265
Polyamide supports for polypeptide synthesis
Atherton, E., Clive, D. L. J., & Sheppard, R. C. (1975) · Journal of the American Chemical Society · doi:10.1021/ja00855a053 · Cited by 224 · cited 1×
“Y3-TATE was prepared on solid support by standard Fmoc procedure (32, 33) using an Advanced Chem Tech peptide synthesizer.”
MethodWu, A. M., Yazaki, P. J., Tsai, S.-W., Nguyen, K., Anderson, A.-L., McCarthy, D. W., Welch, M. J., Shively, J. E., Williams, L. E., Raubitschek, A. A., et al. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.150228297 · Cited by 214
Cited by
Wadas, T. J., Wong, E. H., Weisman, G. R., & Anderson, C. J. (2010) · Chemical Reviews · doi:10.1021/cr900325h · Cited by 924
Self-citationRadiometals for Combined Imaging and Therapy
Cutler, C. S., Hennkens, H. M., Sisay, N., Huclier-Markai, S., & Jurisson, S. S. (2013) · Chemical Reviews · doi:10.1021/cr3003104 · Cited by 395
Antunes, P., Ginj, M., Zhang, H., Waser, B., Baum, R. P., Reubi, J. C., & Maecke, H. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0317-x · Cited by 393
Anderson, C. J., & Ferdani, R. (2009) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/cbr.2009.0674 · Cited by 374
Self-citationRadiolabeled Peptides: Valuable Tools for the Detection and Treatment of Cancer
Fani, M., Maecke, H. R., & Okarvi, S. M. (2012) · Theranostics · doi:10.7150/thno.4024 · Cited by 333
Shokeen, M., & Anderson, C. J. (2009) · Accounts of Chemical Research · doi:10.1021/ar800255q · Cited by 315
Self-citationCopper Chelation Chemistry and its Role in Copper Radiopharmaceuticals
Wadas, T., Wong, E., Weisman, G., & Anderson, C. (2007) · Current Pharmaceutical Design · doi:10.2174/138161207779313768 · Cited by 296
Self-citationRadiopharmaceutical development of radiolabelled peptides
Fani, M., & Maecke, H. R. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-2001-z · Cited by 214
Prasanphanich, A. F., Nanda, P. K., Rold, T. L., Ma, L., Lewis, M. R., Garrison, J. C., Hoffman, T. J., Sieckman, G. L., Figueroa, S. D., & Smith, C. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705347104 · Cited by 213
Radiopharmaceutical chemistry for positron emission tomography
Li, Z., & Conti, P. S. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.09.007 · Cited by 212
Zeglis, B. M., & Lewis, J. S. (2011) · Dalton Transactions · doi:10.1039/c0dt01595d · Cited by 198
Molecular imaging targeting peptide receptors
Schottelius, M., & Wester, H.-J. (2009) · Methods · doi:10.1016/j.ymeth.2009.03.012 · Cited by 194
A Novel Technology for the Imaging of Acidic Prostate Tumors by Positron Emission Tomography
Vāvere, A. L., Biddlecombe, G. B., Spees, W. M., Garbow, J. R., Wijesinghe, D., Andreev, O. A., Engelman, D. M., Reshetnyak, Y. K., & Lewis, J. S. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-3781 · Cited by 185
“The cross-bridged cyclam chelator, CBTE2A, has shown improved in vivo stability and consequently a reduction in transchelation (35, 36) but requires elevated temperatures for copper complexation that may not compatible with the pHLIP construct.”
BackgroundDevelopment of copper based drugs, radiopharmaceuticals and medical materials
Szymański, P., Frączek, T., Markowicz, M., & Mikiciuk-Olasik, E. (2012) · BioMetals · doi:10.1007/s10534-012-9578-y · Cited by 183
Wadas, T. J., Eiblmaier, M., Zheleznyak, A., Sherman, C. D., Ferdani, R., Liang, K., Achilefu, S., & Anderson, C. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054502 · Cited by 73
“We chose to evaluate (64)Cu-CB-TE2A-sst2-ANT in the AR42J model, because it is a model used to evaluate several radiometal-labeled somatostatin analogs (10,19).”
BackgroundMethodResultInfluentialSelf-citation
Metadata
- Authors
- Sprague, J. E., Peng, Y., Sun, X., Weisman, G. R., Wong, E. H., Achilefu, S., & Anderson, C. J.
- Venue
- Clinical Cancer Research
- Published
- 2004-12-15
- Volume
- 10
- Issue
- 24
- Pages
- 8674-8682
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2116290973
- Cited by
- 158
- References
- 30
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.