Value of 18F-Fluoro-2-Deoxy-d-Glucose-Positron Emission Tomography/Computed Tomography in Non–Small-Cell Lung Cancer for Prediction of Pathologic Response and Times to Relapse after Neoadjuvant Chemoradiotherapy
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Purpose: To determine the value of combined positron emission tomography/computed tomography (PET/CT) during induction chemotherapy (CTx) followed by chemoradiotherapy (CTx/RTx) for non–small-cell lung cancer to predict histopathologic response in primary tumor and mediastinum and prognosis of the patient. Experimental Design: Fifty consecutive patients with locally advanced non–small-cell lung cancer received induction therapy and, if considered resectable, proceeded to surgery (37 of 50 patients). Patients had at least two repeated 18F-2-fluoro-2-deoxy-d-glucose (FDG)-PET/CT scans either before treatment (t0) or after induction CTx (t1) or CTx/RTx (t2). Variables from the PET/CT studies [e.g., lesion volume and corrected maximum standardized glucose uptake values (SUVmax,corr)] were correlated with histopathologic response (graded as 3, 2b, or 2a: 0%, >0-10%, or >10% residual tumor cells) and times to failure. Results: Primary tumors showed a percentage decrease in SUVmax,corr during induction significantly larger in grade 2b/3 than in grade 2a responding tumors (67% versus 34% at t1, 73% versus 49% at t2; both P < 0.005). SUVmax,corr at t2 was significantly correlated with histopathologic response in tumors smaller than the median volume (7.5 cm3; r = −0.54, P = 0.02). In the mediastinal lymph nodes, SUVmax,corr values at t2 predicted an ypN0 status with a sensitivity and specificity of 73% and 89%, respectively (SUVmax,corr threshold of 4.1, r = −0.54, P = 0.0005). Freedom from extracerebral relapse was significantly better in grade 2b/3 patients (86% at 16 months versus 20% in 2a responders; P = 0.003) and in patients with a greater percentage decrease in SUVmax,corr in the primary tumor at t2 in relation to t0 than in patients with lesser response (83% at 16 months versus 43%; P = 0.03 for cutoff points between 0.45 and 0.55). Conclusions: SUVmax,corr values from two serial PET/CT scans, before and after three chemotherapy cycles or later, allow prediction of histopathologic response in the primary tumor and mediastinal lymph nodes and have prognostic value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Revisions in the International System for Staging Lung Cancer
Mountain, C. F. (1997) · Chest · doi:10.1378/chest.111.6.1710 · Cited by 4,565
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Albain, K. S., Rusch, V. W., Crowley, J. J., Rice, T. W., Turrisi, A. T., Weick, J. K., Lonchyna, V. A., Presant, C. A., McKenna, R. J., & Gandara, D. R. (1995) · Journal of Clinical Oncology · doi:10.1200/jco.1995.13.8.1880 · Cited by 856
Gould, M. K., Kuschner, W. G., Rydzak, C. E., Maclean, C. C., Demas, A. N., Shigemitsu, H., Chan, J. K., & Owens, D. K. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-11-200311180-00013 · Cited by 687
Non–Small Cell Lung Cancer: Dual-Modality PET/CT in Preoperative Staging
Antoch, G., Stattaus, J., Nemat, A. T., Marnitz, S., Beyer, T., Kuehl, H., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2003) · Radiology · doi:10.1148/radiol.2292021598 · Cited by 540
Self-citationStrauss, L. G. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01367602 · Cited by 527
Weber, W. A., Petersen, V., Schmidt, B., Tyndale-Hines, L., Link, T., Peschel, C., & Schwaiger, M. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.12.004 · Cited by 493
Wieder, H. A., Brücher, B. L. D. M., Zimmermann, F., Becker, K., Lordick, F., Beer, A., Schwaiger, M., Fink, U., Siewert, J. R., Stein, H. J., et al. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.07.122 · Cited by 454
Mac Manus, M. P., Hicks, R. J., Matthews, J. P., McKenzie, A., Rischin, D., Salminen, E. K., & Ball, D. L. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.07.054 · Cited by 439
Cited by
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
“Studies in which complex partial-volume corrections have been performed in addition to corrections for background spillover from nearby tissues have sometimes, but not consistently, demonstrated quantitation to be superior to visual assessments for predicting response and outcome (136).”
BackgroundGold nanostructures: a class of multifunctional materials for biomedical applications
Cobley, C. M., Chen, J., Cho, E. C., Wang, L. V., & Xia, Y. (2011) · Chem. Soc. Rev. · doi:10.1039/b821763g · Cited by 792
Gold Nanocages as Photothermal Transducers for Cancer Treatment
Chen, J., Glaus, C., Laforest, R., Zhang, Q., Yang, M., Gidding, M., Welch, M. J., & Xia, Y. (2010) · Small · doi:10.1002/smll.200902216 · Cited by 691
De Ruysscher, D., Faivre-Finn, C., Nestle, U., Hurkmans, C. W., Le Péchoux, C., Price, A., & Senan, S. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2010.30.3271 · Cited by 364
A Review of Applications of Metabolomics in Cancer
Beger, R. (2013) · Metabolites · doi:10.3390/metabo3030552 · Cited by 288
Multimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Gold Nanocages: A Novel Class of Multifunctional Nanomaterials for Theranostic Applications
Chen, J., Yang, M., Zhang, Q., Cho, E. C., Cobley, C. M., Kim, C., Glaus, C., Wang, L. V., Welch, M. J., & Xia, Y. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201001329 · Cited by 236
Clinical use of circulating nucleosomes
Holdenrieder, S., & Stieber, P. (2009) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360802485875 · Cited by 200
Benz, M. R., Czernin, J., Allen-Auerbach, M. S., Tap, W. D., Dry, S. M., Elashoff, D., Chow, K., Evilevitch, V., Eckardt, J. J., Phelps, M. E., et al. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-2537 · Cited by 197
Targeting gold nanocages to cancer cells for photothermal destruction and drug delivery
Cobley, C. M., Au, L., Chen, J., & Xia, Y. (2010) · Expert Opinion on Drug Delivery · doi:10.1517/17425240903571614 · Cited by 191
“This technique allows for non-invasive observations of tumor metabolic activity, which indicates whether or not the treatment was successful [67-70].”
MethodCurrent Status and Future Perspectives on Neoadjuvant Therapy in Lung Cancer
Blumenthal, G. M., Bunn, P. A., Chaft, J. E., McCoach, C. E., Perez, E. A., Scagliotti, G. V., Carbone, D. P., Aerts, H. J. W. L., Aisner, D. L., Bergh, J., et al. (2018) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2018.09.017 · Cited by 184
Self-citationCurrent concepts in clinical radiation oncology
Orth, M., Lauber, K., Niyazi, M., Friedl, A. A., Li, M., Maihöfer, C., Schüttrumpf, L., Ernst, A., Niemöller, O. M., & Belka, C. (2014) · Radiation and Environmental Biophysics · doi:10.1007/s00411-013-0497-2 · Cited by 178
Use of new imaging techniques to predict tumour response to therapy
Harry, V. N., Semple, S. I., Parkin, D. E., & Gilbert, F. J. (2010) · The Lancet Oncology · doi:10.1016/s1470-2045(09)70190-1 · Cited by 176
William, W. N., Pataer, A., Kalhor, N., Correa, A. M., Rice, D. C., Wistuba, I. I., Heymach, J., Lee, J. J., Kim, E. S., Munden, R., et al. (2013) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e3182774108 · Cited by 138
Bahce, I., Vos, C. G., Dickhoff, C., Hartemink, K. J., Dahele, M., Smit, E. F., Boellaard, R., Hoekstra, O. S., & Thunnissen, E. (2014) · Lung Cancer · doi:10.1016/j.lungcan.2014.04.010 · Cited by 25
Fledelius, J., Khalil, A., Hjorthaug, K., & Frøkiær, J. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0223-6 · Cited by 24
Metadata
- Authors
- Pöttgen, C., Levegrün, S., Theegarten, D., Marnitz, S., Grehl, S., Pink, R., Eberhardt, W., Stamatis, G., Gauler, T., Antoch, G., Bockisch, A., & Stuschke, M.
- Venue
- Clinical Cancer Research
- Published
- 2006-01-01
- Volume
- 12
- Issue
- 1
- Pages
- 97-106
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2131481219
- Cited by
- 204
- References
- 31
- FWCI
- 20.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.