The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Test Performance of Positron Emission Tomography and Computed Tomography for Mediastinal Staging in Patients with Non–Small-Cell Lung Cancer: A Meta-Analysis
Abstract
PURPOSE: To compare the diagnostic accuracy of computed tomography (CT) and positron emission tomography (PET) with 18-fluorodeoxyglucose (FDG) for mediastinal staging in patients with non-small-cell lung cancer and to determine whether test results are conditionally dependent (the sensitivity and specificity of FDG-PET depend on the presence or absence of enlarged mediastinal lymph nodes on CT). DATA SOURCES: Computerized search of MEDLINE, EMBASE, BIOSIS, and CancerLit through March 2003 and reference lists of retrieved studies and review articles. STUDY SELECTION: Studies in any language that examined FDG-PET for mediastinal staging in patients with known or suspected non-small-cell lung cancer, enrolled at least 10 participants (including at least 5 participants with mediastinal metastasis), and provided enough data to permit calculation of sensitivity and specificity for identifying lymph node involvement. DATA EXTRACTION: One reviewer (of non-English-language studies) or 2 reviewers (of English-language studies) independently evaluated studies for inclusion, rated methodologic quality, and abstracted relevant data. DATA SYNTHESIS: Thirty-nine studies met inclusion criteria. Methodologic quality varied, but few aspects of study quality affected diagnostic accuracy. The authors constructed summary receiver-operating characteristic curves for CT and FDG-PET. Positron emission tomography with 18-fluorodeoxyglucose was more accurate than CT for identifying lymph node involvement (P < 0.001). For CT, median sensitivity and specificity were 61% (interquartile range, 50% to 71%) and 79% (interquartile range, 66% to 89%), respectively. For FDG-PET, median sensitivity and specificity were 85% (interquartile range, 67% to 91%) and 90% (interquartile range, 82% to 96%), respectively. Fourteen studies provided information about the conditional test performance of CT and FDG-PET. Positron emission tomography with 18-fluorodeoxyglucose was more sensitive but less specific when CT showed enlarged lymph nodes (median sensitivity, 100% [interquartile range, 90% to 100%]; median specificity, 78% [interquartile range, 68% to 100%]) than when CT showed no lymph node enlargement (median sensitivity, 82% [interquartile range, 65% to 100%]; median specificity, 93% [interquartile range, 92% to 100%]; P = 0.002). CONCLUSIONS: Positron emission tomography with 18-fluorodeoxyglucose is more accurate than CT for mediastinal staging. Positron emission tomography with 18-fluorodeoxyglucose is more sensitive but less specific when CT shows enlarged mediastinal lymph nodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
Quantitative Synthesis in Systematic Reviews
Lau, J., Ioannidis, J. P. A., & Schmid, C. H. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-9-199711010-00008 · Cited by 2,517 · cited 1×
“We used meta-regression to make all statistical comparisons (19), with 1 exception.”
MethodMultivariate Analysis: Methods and Applications
Dillon, W. R., & Goldstein, M. (1984) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,905
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Nonparametric estimates of standard error: The jackknife, the bootstrap and other methods
EFRON, B. (1981) · Biometrika · doi:10.1093/biomet/68.3.589 · Cited by 1,399
Methods in Observational Epidemiology
Kelsey, J. L. (1986) · Cited by 1,307
Preoperative Staging of Non–Small-Cell Lung Cancer with Positron-Emission Tomography
Pieterman, R. M., van Putten, J. W. G., Meuzelaar, J. J., Mooyaart, E. L., Vaalburg, W., Koëter, G. H., Fidler, V., Pruim, J., & Groen, H. J. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007273430404 · Cited by 1,111
Gould, M. K., Maclean, C. C., Kuschner, W. G., Rydzak, C. E., & Owens, D. K. (2001) · JAMA · doi:10.1001/jama.285.7.914 · Cited by 1,094
Self-citation
Cited by
Methods for Staging Non-small Cell Lung Cancer
Silvestri, G. A., Gonzalez, A. V., Jantz, M. A., Margolis, M. L., Gould, M. K., Tanoue, L. T., Harris, L. J., & Detterbeck, F. C. (2013) · Chest · doi:10.1378/chest.12-2355 · Cited by 1,483
Self-citationRecommendations on the Use of 18F-FDG PET in Oncology
Fletcher, J. W., Djulbegovic, B., Soares, H. P., Siegel, B. A., Lowe, V. J., Lyman, G. H., Coleman, R. E., Wahl, R., Paschold, J. C., Avril, N., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.047787 · Cited by 1,101
Noninvasive Staging of Non-small Cell Lung Cancer*
Toloza, E. M., Harpole, L., & McCrory, D. C. (2003) · Chest · doi:10.1378/chest.123.1_suppl.137s · Cited by 745
_, _. (2008) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2008.0021 · Cited by 735
Invasive Mediastinal Staging of Lung Cancer
Detterbeck, F. C., Jantz, M. A., Wallace, M., Vansteenkiste, J., & Silvestri, G. A. (2007) · Chest · doi:10.1378/chest.07-1362 · Cited by 685
Metadata
- Authors
- Gould, M. K., Kuschner, W. G., Rydzak, C. E., Maclean, C. C., Demas, A. N., Shigemitsu, H., Chan, J. K., & Owens, D. K.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2003-12-02
- Volume
- 139
- Issue
- 11
- Pages
- 879-892
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2058839291
- Cited by
- 687
- References
- 56
- FWCI
- 22.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Test Performance of Positron Emission Tomography and Computed Tomography for Mediastinal Staging in Patients with Non–Small-Cell Lung Cancer: A Meta-Analysis. https://app.cochat.ai/papers/10.7326/0003-4819-139-11-200311180-00013
- The paper
- Gould, M. K., Kuschner, W. G., Rydzak, C. E., Maclean, C. C., Demas, A. N., Shigemitsu, H., Chan, J. K., & Owens, D. K. (2003). Test Performance of Positron Emission Tomography and Computed Tomography for Mediastinal Staging in Patients with Non–Small-Cell Lung Cancer: A Meta-Analysis. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-139-11-200311180-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.