CoChat

Comparison of the 1-Gram 14C-D-Xylose Breath Test and the 50-Gram Hydrogen Glucose Breath Test for Diagnosis of Small Intestinal Bacterial Overgrowth

Stotzer, Per-Ove, Kilander, Anders F. · 2000 · Digestion
Cited by 73

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background/Aims: Culture of small bowel aspirate is the most direct method and the gold standard for diagnosing small intestinal bacterial overgrowth. However, cultures are cumbersome and fluoroscopy is required for obtaining aspirate. Therefore, different breath tests such as the xylose breath test and the hydrogen breath test have been developed. There is no general agreement as to which test is to be preferred. In the only previous direct comparison between these two tests an advantage for the 1-gram-14 C-D-xylose breath test was found. The aim of the study was to compare the 50-gram glucose hydrogen breath test and the 1-gram 14 C-D-xylose breath test in relation to results of cultures of small bowel aspirate. Methods: Forty-six consecutive patients, mean age 57 (range 27–87) years, 12 men and 34 women, were included because of suspicion of small intestinal bacterial overgrowth. After small bowel aspiration, all patients received a solution of 1 g xylose, labelled with 50 µg 14 C-D-xylose, and 50 g glucose dissolved in 250 ml water. The concentration of breath hydrogen was analyzed every 15 min for 2 h and 14 CO 2 was analyzed every 30 min for 4 h. A positive hydrogen breath test was defined as a rise in hydrogen concentration of 15 ppm. A positive xylose test was defined as an accumulated dose 4.5% after 4 h. Two definitions for a positive culture were used, either growth of 10 5 colonic-type bacteria/ml or growth of 10 5 bacteria/ml of any type. Results: Twenty-four patients had growth of 10 5 bacteria, of whom 10 had growth of 10 5 colonic-type bacteria in small bowel aspirate. Twenty-two patients had no significant growth. The hydrogen breath test and the xylose breath test had a sensitivity for growth of 10 5 bacteria of 58 and 42%, respectively. For growth of 10 5 colonic-type bacteria the sensitivity was 90% for the hydrogen breath test and 70% for the xylose breath test. The specificity was similar for the two tests. Conclusion: Although no significant difference between the two tests was found, there was a tendency in favor of the 50-gram glucose hydrogen breath test. The simplicity in combination with high sensitivity makes the hydrogen breath test suitable as a screening method to select patients for further investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000007753

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Stotzer, P.-O., & Kilander, A. F.
Venue
Digestion
Publisher
S. Karger AG
Published
2000
Volume
61
Issue
3
Pages
165-171
ISSN
  • 0012-2823 (ISSN-L)
  • 1421-9867
OpenAlex
W1996827163
Cited by
73
References
1
FWCI
2.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.