The DOI matches its Crossref record.
High-Precision Neuromagnetic Study of the Functional Organization of the Human Auditory Cortex
Abstract
Previous studies have proven that a dipole source analysis of the auditory evoked field is capable of providing evidence of the tonotopic organization of the human auditory cortex. To explore the nature of the estimated dipoles in greater detail, a single subject was extensively studied, and the estimated sources were registered in a three-dimensional reconstruction of the cortical surface derived from magnetic resonance images. The stimuli were 500-ms tone bursts with frequencies of 250, 500, 1,000, and 2,000 Hz (mean intensity of 60 dB SL). The total number of stimuli presented per condition was about 3,600 (36 independent experiments spread over 4 days). Using special postprocessing techniques, the relative localization accuracy could be enhanced to such an extent that differences in the dipole locations of 1 mm could be clearly distinguished. The results suggest that peak N1m (latency around 100 ms) arises from the planum temporale, whereas peak P2m (latency around 170 ms) appears to correspond to a center of activity in (or close to) Heschl’s gyrus. The tonotopic organization found for the generator of N1m was consistent with earlier studies (‘the higher the frequency the deeper the source’). However, additional findings (time dependence of the estimated sources; slightly different tonotopy obtained for field change; dependence of the estimated sources on the estimation technique) indicate that multiple areas are involved in the generation of N1m. Evidence of a frequency-dependent source location was found also for P2m.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Emergence of neural encoding of auditory objects while listening to competing speakers
Ding, N., & Simon, J. Z. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1205381109 · Cited by 835
Doelling, K. B., Arnal, L. H., Ghitza, O., & Poeppel, D. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.035 · Cited by 571
Mismatch negativity (MMN), the deviance-elicited auditory deflection, explained
May, P. J. C., & Tiitinen, H. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2009.00856.x · Cited by 549
Hackett, T. A., Preuss, T. M., & Kaas, J. H. (2001) · Journal of Comparative Neurology · doi:10.1002/cne.1407 · Cited by 517
Probabilistic Mapping and Volume Measurement of Human Primary Auditory Cortex
Rademacher, J., Morosan, P., Schormann, T., Schleicher, A., Werner, C., Freund, H.-J., & Zilles, K. (2001) · NeuroImage · doi:10.1006/nimg.2000.0714 · Cited by 503
Metadata
- Authors
- Lütkenhöner, B., & Steinsträter, O.
- Venue
- Audiology and Neurotology
- Publisher
- S. Karger AG
- Published
- 1998
- Volume
- 3
- Issue
- 2-3
- Pages
- 191-213
- ISSN
- 1420-3030 (ISSN-L)
- 1421-9700
- OpenAlex
- W1999080481
- Cited by
- 288
- References
- 0
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Precision Neuromagnetic Study of the Functional Organization of the Human Auditory Cortex. https://app.cochat.ai/papers/10.1159/000013790
- The paper
- Lütkenhöner, B., & Steinsträter, O. (1998). High-Precision Neuromagnetic Study of the Functional Organization of the Human Auditory Cortex. Audiology and Neurotology. https://doi.org/10.1159/000013790
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.