Viewing the Microcirculation through the Window: Some Twenty Years Experience with the Hamster Dorsal Skinfold Chamber
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Intravital microscopy represents a sophisticated technique to study the microcirculation in health and disease. While most preparations used for those studies are acute in nature, the use of chamber preparations in the skinfold bear the advantage to allow for chronic studies with repeated analysis of the microcirculation over a prolonged period of time. The skinfold chamber model for microcirculatory analysis has been adapted to mice, rats and hamsters. Although the use of rats and, in particular, the use of mice has the advantage of the availability of species-specific tools, the use of the hamster as the experimental animal may be preferred due to anatomical reasons, which facilitate the microsurgical preparation and improve the quality of microscopic imaging. The use of the hamster dorsal skinfold chamber, firstly described by Endrich and coworkers in 1980, has brought out during the last two decades a considerable number of experimental studies within the fields of microcirculation physiology, inflammation and sepsis, ischemia-reperfusion, angiogenesis, and transplantation, indicating that the model has to be considered a versatile tool to study the microcirculation in health and disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vollmar, B., Westermann, S., & Menger, M. D. (1999) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199901000-00015 · Cited by 68
Self-citation
Cited by
A Molecular Imaging Primer: Modalities, Imaging Agents, and Applications
James, M. L., & Gambhir, S. S. (2012) · Physiological Reviews · doi:10.1152/physrev.00049.2010 · Cited by 1,140
A critical analysis of current in vitro and in vivo angiogenesis assays
Staton, C. A., Reed, M. W. R., & Brown, N. J. (2009) · International Journal of Experimental Pathology · doi:10.1111/j.1365-2613.2008.00633.x · Cited by 469
Park, S. O., Wankhede, M., Lee, Y. J., Choi, E.-J., Fliess, N., Choe, S.-W., Oh, S.-H., Walter, G., Raizada, M. K., Sorg, B. S., et al. (2009) · Journal of Clinical Investigation · doi:10.1172/jci39482 · Cited by 300
Drug delivery to solid tumors by elastin-like polypeptides
McDaniel, J. R., Callahan, D. J., & Chilkoti, A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.05.004 · Cited by 217
“The window chamber model allows for real-time optical imaging within the vascular and extravascular space of the implanted tumor [57,58].”
Serial noninvasive photoacoustic imaging of neovascularization in tumor angiogenesis
Siphanto, R. I., Thumma, K. K., Kolkman, R. G. M., van Leeuwen, T. G., de Mul, F. F. M., van Neck, J. W., van Adrichem, L. N. A., & Steenbergen, W. (2005) · Optics Express · doi:10.1364/opex.13.000089 · Cited by 205
Metadata
- Authors
- Menger, M. D., Laschke, M. W., & Vollmar, B.
- Venue
- European Surgical Research
- Publisher
- S. Karger AG
- Published
- 2002
- Volume
- 34
- Issue
- 1-2
- Pages
- 83-91
- ISSN
- 0014-312X (ISSN-L)
- 1421-9921
- OpenAlex
- W1968316164
- Cited by
- 138
- References
- 1
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.