The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Location of Resistance Arteries
Abstract
Thickening and narrowing of resistance arteries must, by definition, be key elements in the control of the cardiovascular system. However, the precise location of resistance arteries is difficult to establish. This is due to technical problems related to the small size of the vessels, to the measurement conditions disturbing the hemodynamics, and to the status of the animals while the measurements are being made. Furthermore, due to large data heterogeneity, previous studies do not give unequivocal information concerning the pressure profile in the vascular system, or the level of arterial diameter responsible for blood flow. Finally, and importantly, there is little evidence regarding the conscious state, which is thus a major limitation to understanding the mechanisms of blood distribution and the pathogenesis for disease processes such as genetic hypertension. This review first summarizes briefly the techniques which are available for identifying resistance arteries and the inherent technical limitations which are involved. The review then provides a critical assessment of the available data, both as regards measurement of local blood pressures and as regards control of peripheral resistance. The evidence suggests that, at least as regards rats and other small animals, feed arteries as well as more distal microvessels contribute to the maintenance and regulation of blood flow and resistance. Evidence from larger animals is however lacking, and it is thus unclear if resistance function should be based on arterial diameter or anatomic location. Furthermore, evidence concerning man is not available. We therefore conclude the review with suggestions for future research in this area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological aspects of primary hypertension.
Folkow, B. (1982) · Physiological Reviews · doi:10.1152/physrev.1982.62.2.347 · Cited by 1,768
Cited by
Mechanical Factors in Arterial Aging
O’Rourke, M. F., & Hashimoto, J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.050 · Cited by 1,250
Safar, M. E., Levy, B. I., & Struijker-Boudier, H. (2003) · Circulation · doi:10.1161/01.cir.0000069826.36125.b4 · Cited by 1,197
Vascular smooth muscle contraction in hypertension
Touyz, R. M., Alves-Lopes, R., Rios, F. J., Camargo, L. L., Anagnostopoulou, A., Arner, A., & Montezano, A. C. (2018) · Cardiovascular Research · doi:10.1093/cvr/cvy023 · Cited by 697
Small-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
How vascular smooth muscle cell phenotype switching contributes to vascular disease
Cao, G., Xuan, X., Hu, J., Zhang, R., Jin, H., & Dong, H. (2022) · Cell Communication and Signaling · doi:10.1186/s12964-022-00993-2 · Cited by 431
Metadata
- Authors
- Christensen, K. L., & Mulvany, M. J.
- Venue
- Journal of Vascular Research
- Publisher
- S. Karger AG
- Published
- 2001
- Volume
- 38
- Issue
- 1
- Pages
- 1-12
- ISSN
- 1018-1172 (ISSN-L)
- 1423-0135
- OpenAlex
- W2039996525
- Cited by
- 214
- References
- 1
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Location of Resistance Arteries. https://app.cochat.ai/papers/10.1159/000051024
- The paper
- Christensen, K. L., & Mulvany, M. J. (2001). Location of Resistance Arteries. Journal of Vascular Research. https://doi.org/10.1159/000051024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.