EEG Source Localization and Global Dimensional Complexity in High- and Low- Hypnotizable Subjects: A Pilot Study
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Individuals differ in hypnotizability. Information on hypnotizability-related EEG characteristics is controversial and incomplete, particularly on intracerebral source localization and EEG dimensionality. 19-channel, eyes-closed resting EEGs from right-handed, healthy, 8 high- and 4 low-hynotizable subjects (age: 26.7 ± 7.3 years) were analyzed. Hypnotizability was rated after the subjects’ ability to attain a deep hypnotic stage (amnesia). FFT Dipole Approximation analysis in seven EEG frequency bands showed significant differences (p < 0.04) of source gravity center locations for theta (6.5–8 Hz, more posterior and more left for highs), beta-1 and beta-2 frequencies (12.5–18 and 18.5–21 Hz; both more posterior and more right for highs). Low Resolution Electromagnetic Tomography (LORETA) specified the cortical anteriorization of beta-1 and beta-2 in low hypnotizables. Power spectral analysis of Global Field Power time series (curves) showed no overall power differences in any band. Full-band Global Dimensional Complexity was higher in high-hypnotizable subjects (p < 0.02). Thus, before hypnosis, high and low hypnotizables were in different brain electric states, with more posterior brain activity gravity centers (excitatory right, routine or relaxation left) and higher dimensional complexity (higher arousal) in high than low hypnotizables.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Self-citationAdjunctive non-pharmacological analgesia for invasive medical procedures: a randomised trial
Lang, E. V., Benotsch, E. G., Fick, L. J., Lutgendorf, S., Berbaum, M. L., Berbaum, K. S., Logan, H., & Spiegel, D. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02162-0 · Cited by 513
EEG and hypnotic susceptibility.
Galbraith, G. C., London, P., Leibovitz, M. P., Cooper, L. M., & Hart, J. T. (1970) · Journal of Comparative and Physiological Psychology · doi:10.1037/h0029278 · Cited by 71
EEG spectral analysis during hypnotic induction, hypnotic dream and age regression
De Pascalis, V. (1993) · International Journal of Psychophysiology · doi:10.1016/0167-8760(93)90073-x · Cited by 40
Schnyer, D. M., & Allen, J. J. (1995) · International Journal of Clinical and Experimental Hypnosis · doi:10.1080/00207149508409972 · Cited by 25
Cited by
Psychobiology of Altered States of Consciousness.
Vaitl, D., Birbaumer, N., Gruzelier, J., Jamieson, G. A., Kotchoubey, B., Kübler, A., Lehmann, D., Miltner, W. H. R., Ott, U., Pütz, P., et al. (2005) · Psychological Bulletin · doi:10.1037/0033-2909.131.1.98 · Cited by 448
“Owing to this scarcity of empirical evidence, these brain diseases are not reviewed here.”
BackgroundSelf-citationSources of cortical rhythms in adults during physiological aging: A multicentric EEG study
Babiloni, C., Binetti, G., Cassarino, A., Dal Forno, G., Del Percio, C., Ferreri, F., Ferri, R., Frisoni, G., Galderisi, S., Hirata, K., et al. (2006) · Human Brain Mapping · doi:10.1002/hbm.20175 · Cited by 314
Babiloni, C., Binetti, G., Cassetta, E., Forno, G. D., Percio, C. D., Ferreri, F., Ferri, R., Frisoni, G., Hirata, K., Lanuzza, B., et al. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.09.019 · Cited by 285
Rossini, P. M., Del Percio, C., Pasqualetti, P., Cassetta, E., Binetti, G., Dal Forno, G., Ferreri, F., Frisoni, G., Chiovenda, P., Miniussi, C., et al. (2006) · Neuroscience · doi:10.1016/j.neuroscience.2006.08.049 · Cited by 281
“Firstly, LORETA has been repeatedly used from data collected by low spatial sampling of 10 –20 system (19 electrodes, Isotani et al., 2001; Anderer et al., 2003; Veiga et al., 2003Ka- wasaki et al., 2004; Laufer and Pratt, 2003a,b; Babiloni et al., 2004a, 2006a).”
Mechanisms of Hypnosis:Toward the Development of a Biopsychosocial Model
Jensen, M. P., Adachi, T., Tomé-Pires, C., Lee, J., Osman, Z. J., & Miró, J. (2015) · International Journal of Clinical and Experimental Hypnosis · doi:10.1080/00207144.2014.961875 · Cited by 202
“, 2013) and in the brain areas (source locations) associated with theta and beta activity (Isotani et al., 2001).”
Background
Metadata
- Authors
- Isotani, T., Lehmann, D., Pascual-Marqui, R. D., Kochi, K., Wackermann, J., Saito, N., Yagyu, T., Kinoshita, T., & Sasada, K.
- Venue
- Neuropsychobiology
- Publisher
- S. Karger AG
- Published
- 2001
- Volume
- 44
- Issue
- 4
- Pages
- 192-198
- ISSN
- 0302-282X (ISSN-L)
- 1423-0224
- OpenAlex
- W2022621100
- Cited by
- 39
- References
- 5
- FWCI
- 0.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.