Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG Method

Guenot, Marc, Isnard, Jean, Ryvlin, Philippe, Fischer, Catherine, Ostrowsky, Karine, Mauguiere, François, Sindou, Marc·2001·Stereotactic and Functional Neurosurgery

Abstract

Object of the Study: In some candidates for epilepsy surgery in whom the decision to operate is difficult to make, invasive presurgical investigations, namely depth electrode recordings, may be needed. The SEEG (StereoElectroEncephaloGraphy) method consists of stereotactic orthogonal implantation of depth electrodes (5 to 15, 11 on average). The object of this study is to clarify the indications for SEEG, to expose its complications, and to display its usefulness in terms of surgical strategy and results. Patients and Methods: 100 patients, suffering from drug-resistant epilepsy and selected as candidates for surgical resection, underwent SEEG between 1996 and 2000. A total of 1,118 electrodes were implanted. For each single case, the sites of implantation of the electrodes were chosen in order to determine either the side of the onset of seizures, or the uni- or multilobar feature of them, or a possible operculo-insular propagation from a temporal onset, and also, using direct electrode stimulation, the proximity of speech or motor area. Results: Complications occurred in 5 patients (2 superficial infections, 2 breakages of electrodes, and 1 intracerebral hematoma responsible for death). SEEG was helpful in most (84%) of the 100 patients to confirm or annul surgical indication, and to adjust the extent of the resection. In some cases (14%), SEEG allowed to propose a resection that might have been disputable based solely on noninvasive investigation data. For frontal epilepsy, SEEG was crucial in all cases to delineate the extent of resection. Conclusion: SEEG proved to be a relatively safe and a very useful method in ‘difficult’ candidates for epilepsy surgery. In addition, in some cases the implanted electrodes can be used to perform therapeutic RF thermocoagulation of epileptic foci or networks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000064595

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 232

Metadata

Authors
Guenot, M., Isnard, J., Ryvlin, P., Fischer, C., Ostrowsky, K., Mauguiere, F., & Sindou, M.
Venue
Stereotactic and Functional Neurosurgery
Publisher
S. Karger AG
Published
2001
Volume
77
Issue
1-4
Pages
29-32
ISSN
  • 1011-6125 (ISSN-L)
  • 1423-0372
OpenAlex
W1964389368
Cited by
232
References
0
FWCI
1.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG Method. https://app.cochat.ai/papers/10.1159/000064595
The paper
Guenot, M., Isnard, J., Ryvlin, P., Fischer, C., Ostrowsky, K., Mauguiere, F., & Sindou, M. (2001). Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG Method. Stereotactic and Functional Neurosurgery. https://doi.org/10.1159/000064595

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.