The DOI matches its Crossref record.
Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG Method
Abstract
Object of the Study: In some candidates for epilepsy surgery in whom the decision to operate is difficult to make, invasive presurgical investigations, namely depth electrode recordings, may be needed. The SEEG (StereoElectroEncephaloGraphy) method consists of stereotactic orthogonal implantation of depth electrodes (5 to 15, 11 on average). The object of this study is to clarify the indications for SEEG, to expose its complications, and to display its usefulness in terms of surgical strategy and results. Patients and Methods: 100 patients, suffering from drug-resistant epilepsy and selected as candidates for surgical resection, underwent SEEG between 1996 and 2000. A total of 1,118 electrodes were implanted. For each single case, the sites of implantation of the electrodes were chosen in order to determine either the side of the onset of seizures, or the uni- or multilobar feature of them, or a possible operculo-insular propagation from a temporal onset, and also, using direct electrode stimulation, the proximity of speech or motor area. Results: Complications occurred in 5 patients (2 superficial infections, 2 breakages of electrodes, and 1 intracerebral hematoma responsible for death). SEEG was helpful in most (84%) of the 100 patients to confirm or annul surgical indication, and to adjust the extent of the resection. In some cases (14%), SEEG allowed to propose a resection that might have been disputable based solely on noninvasive investigation data. For frontal epilepsy, SEEG was crucial in all cases to delineate the extent of resection. Conclusion: SEEG proved to be a relatively safe and a very useful method in ‘difficult’ candidates for epilepsy surgery. In addition, in some cases the implanted electrodes can be used to perform therapeutic RF thermocoagulation of epileptic foci or networks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., et al. (2013) · Neurosurgery · doi:10.1227/neu.0b013e31827d1161 · Cited by 527
Clinical manifestations of insular lobe seizures: a stereo-electroencephalographic study
Isnard, J., Guénot, M., Sindou, M., & Mauguière, F. (2004) · Epilepsia · doi:10.1111/j.0013-9580.2004.68903.x · Cited by 504
Self-citationMullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Cossu, M., Cardinale, F., Castana, L., Citterio, A., Francione, S., Tassi, L., Benabid, A. L., & Russo, G. L. (2005) · Neurosurgery · doi:10.1093/neurosurgery/57.4.706 · Cited by 332
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala-Sterniuk, A., Browarska, N., Al-Bakri, A., Pelc, M., Zygarlicki, J., Sidikova, M., Martinek, R., & Gorzelanczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 292
Metadata
- Authors
- Guenot, M., Isnard, J., Ryvlin, P., Fischer, C., Ostrowsky, K., Mauguiere, F., & Sindou, M.
- Venue
- Stereotactic and Functional Neurosurgery
- Publisher
- S. Karger AG
- Published
- 2001
- Volume
- 77
- Issue
- 1-4
- Pages
- 29-32
- ISSN
- 1011-6125 (ISSN-L)
- 1423-0372
- OpenAlex
- W1964389368
- Cited by
- 232
- References
- 0
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG Method. https://app.cochat.ai/papers/10.1159/000064595
- The paper
- Guenot, M., Isnard, J., Ryvlin, P., Fischer, C., Ostrowsky, K., Mauguiere, F., & Sindou, M. (2001). Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG Method. Stereotactic and Functional Neurosurgery. https://doi.org/10.1159/000064595
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).