Speech Perception in Nucleus CI24M Cochlear Implant Users with Processor Settings Based on Electrically Evoked Compound Action Potential Thresholds
The DOI matches its Crossref record.
Abstract
Adjusting the speech processor of a cochlear implant, per electrode, to the individual’s response is a laborious task that may interfere with a user-friendly start of implant-mediated hearing, particularly in children. This research concerns the possibility of processor adjustment based on a profile derived from measurements of the electrically evoked compound action potential (ECAP) thresholds across the electrode array, followed by adjustment of the overall level of the profile to the hearing threshold and maximum comfortable loudness level using live voice. The results for CVC word lists show that speech perception is quite insensitive to the threshold setting of the speech processor. On average, the speech score does not decrease by more than 10% when, with the new method, the threshold setting comes out so much lower that the dynamic range has doubled. In contrast, the speech score appears to be sensitive to an increase of the maximum high-frequency stimulation settings for the basal electrodes, resulting in lower scores at these higher settings. The correlation between the overall ECAP thresholds and conventionally measured subjective thresholds is weak (r = 0.64). However, the correlation between the slopes of these threshold curves is satisfactory (r = 0.82). The correlation between the ECAP thresholds and the maximum stimulation levels is poor, both with respect to overall level and slope (r = 0.39 and 0.36, respectively). Applicability of the ECAP threshold in processor adjustment could not be demonstrated in this study. Prediction of the most critical factor in speech perception, the slope of the maximum stimulation curve, from the ECAP thresholds is poor. However, considering habituation to the initial processor setting of at least 6 months, the small decrease in the CVC scores with the new setting suggests that a more user-friendly adjustment procedure can be developed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“Such objectively created maps are especially valuable to the increasing pediatric implant populations as well as those who cannot give accurate behavioral responses, but their speech performance is still sub-optimal compared with the behaviorally created maps [171-173].”
BackgroundThe Development of the Nucleus® Freedom™ Cochlear Implant System
Patrick, J. F., Busby, P. A., & Gibson, P. J. (2006) · Trends in Amplification · doi:10.1177/1084713806296386 · Cited by 196
“Fitting methods based on objective measures, such as ECAP, ESRT, and EABR, combined with limited behavioral measures have also been successfully used.(22,25,117,118) The Custom Sound Suite supports streamlined fitting using behavioral and electrophysiologic measures.”
Cochlear Implant Programming: A Global Survey on the State of the Art
Vaerenberg, B., Smits, C., De Ceulaer, G., Zir, E., Harman, S., Jaspers, N., Tam, Y., Dillon, M., Wesarg, T., Martin-Bonniot, D., et al. (2014) · The Scientific World Journal · doi:10.1155/2014/501738 · Cited by 182
“On the contrary, Smoorenburg concluded that the applicability of eCAP measures in processor adjustment could not be demonstrated [18].”
BackgroundCan ECAP measures be used for totally objective programming of cochlear implants?
McKay, C. M., Chandan, K., Akhoun, I., Siciliano, C., & Kluk, K. (2013) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-013-0417-9 · Cited by 81
Guenser, G., Laudanski, J., Phillipon, B., Backus, B. C., Bordure, P., Romanet, P., & Parietti-Winkler, C. (2015) · Cochlear Implants International · doi:10.1179/1754762814y.0000000082 · Cited by 11
Metadata
- Authors
- Smoorenburg, G. F., Willeboer, C., & van Dijk, J. E.
- Venue
- Audiology and Neurotology
- Publisher
- S. Karger AG
- Published
- 2002
- Volume
- 7
- Issue
- 6
- Pages
- 335-347
- ISSN
- 1420-3030 (ISSN-L)
- 1421-9700
- OpenAlex
- W2014838376
- Cited by
- 162
- References
- 0
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Speech Perception in Nucleus CI24M Cochlear Implant Users with Processor Settings Based on Electrically Evoked Compound Action Potential Thresholds. https://app.cochat.ai/papers/10.1159/000066154
- The paper
- Smoorenburg, G. F., Willeboer, C., & van Dijk, J. E. (2002). Speech Perception in Nucleus CI24M Cochlear Implant Users with Processor Settings Based on Electrically Evoked Compound Action Potential Thresholds. Audiology and Neurotology. https://doi.org/10.1159/000066154
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.