Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 679

The DOI matches its Crossref record.

The Calibrated Automated Thrombogram (CAT): a universal routine test for hyper- and hypocoagulability

Open access
Hemker, H.C., Giesen, P., AlDieri, R., Regnault, V., de Smed, E., Wagenvoord, R., Lecompte, T., Béguin, S.·2002·Pathophysiology of Haemostasis and Thrombosis

Abstract

By using a "slow" fluorogenic thrombin substrate and continuous comparison to a simultaneously run calibrator, thrombin generation can be monitored automatically, on line, in clotting PPP or PRP at a throughput of up to 100 samples per hour. The resulting "Thrombogram" in PPP measures hypocoagulability (haemophilias, oral anticoagulants, heparins (-likes), direct inhibitors) and hypercoagulabilities (AT deficiency, prothrombin hyperexpression, prot. C and S deficiency, factor V Leiden, oral contraceptives). In PRP it is diminished in thrombopathies, in von Willebrand disease, by antibodies blocking GPIIb-IIIa or GPIb, or by antiplatelet drugs like aspirin and clopidogrel. Lupus anticoagulant both retards and increases thrombin generation. The thrombogram thus appears to be a broad function test of the haemostatic-thrombotic mechanism of the blood.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000073575

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 679

Metadata

Authors
Hemker, H. C., Giesen, P., AlDieri, R., Regnault, V., de Smed, E., Wagenvoord, R., Lecompte, T., & Béguin, S.
Venue
Pathophysiology of Haemostasis and Thrombosis
Publisher
S. Karger AG
Published
2002
Volume
32
Issue
5-6
Pages
249-253
ISSN
  • 1424-8832 (ISSN-L)
  • 1424-8840
OpenAlex
W2135486988
Cited by
679
References
0
FWCI
1.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Calibrated Automated Thrombogram (CAT): a universal routine test for hyper- and hypocoagulability. https://app.cochat.ai/papers/10.1159/000073575
The paper
Hemker, H. C., Giesen, P., AlDieri, R., Regnault, V., de Smed, E., Wagenvoord, R., Lecompte, T., & Béguin, S. (2002). The Calibrated Automated Thrombogram (CAT): a universal routine test for hyper- and hypocoagulability. Pathophysiology of Haemostasis and Thrombosis. https://doi.org/10.1159/000073575

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.