Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 449

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Assessment of laboratory assays to measure rivaroxaban – an oral, direct factor Xa inhibitor

Martinoli, Jean-Luc, LeFlem, Léna, Guinet, Céline, Plu-Bureau, Geneviève, Depasse, François, Perzborn, Elisabeth, Samama, Meyer Michel·2010·Thrombosis and Haemostasis

Abstract

Summary: Although there is no need for routine coagulation monitoring with rivaroxaban – an oral, direct factor Xa inhibitor – a haemostasis assay might be valuable to measure its pharmacodynamic effects. This study aimed to find assays, among those commercially available, to measure rivaroxaban pharmacodynamics. Several global conventional clotting tests, as well as clotting or chromogenic assays to measure anti-factor Xa activity, were studied. A thrombin generation test using calibrated automated thrombogram was also done. Tests were performed with the indirect factor Xa inhibitor fondaparinux for comparison. A concentration-dependent prolongation of prothrombin time (PT), dilute PT, and activated partial thromboplastin time was observed with rivaroxaban. The results varied depending on the reagents. This variability cannot be standardised with the international normalised ratio system commonly used for vitamin K antagonists. Using a standard calibration curve, PT test results can be expressed in plasma concentrations of rivaroxaban rather than PT seconds or ratio. Standard methods for HepTest and two-step prothrombinase-induced clotting time (PiCT) resulted in a paradoxical response, with low concentrations of rivaroxaban reducing clotting times. This was not observed with shorter incubation times, or when antithrombin-deficient (immunodepleted) plasma was used. The chromogenic tests found a dose-dependent relationship between anti-factor Xa activity and rivaroxaban concentration. Modified specific factor Xa chromogenic assays are being further investigated. One-step PiCT and HepTest with shortened incubation times, as well as the widely available PT assay (using a rivaroxaban calibrator) could be useful to monitor the pharmacodynamic effects of rivaroxaban accurately. Finally, all clotting and chromogenic assays showed a concentration-dependent effect induced by rivaroxaban.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1160/th09-03-0176

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 449

Metadata

Authors
Martinoli, J.-L., LeFlem, L., Guinet, C., Plu-Bureau, G., Depasse, F., Perzborn, E., & Samama, M. M.
Venue
Thrombosis and Haemostasis
Published
2010
Volume
103
Issue
04
Pages
815-825
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W2157224841
Cited by
449
References
14
FWCI
34.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of laboratory assays to measure rivaroxaban – an oral, direct factor Xa inhibitor. https://app.cochat.ai/papers/10.1160/th09-03-0176
The paper
Martinoli, J.-L., LeFlem, L., Guinet, C., Plu-Bureau, G., Depasse, F., Perzborn, E., & Samama, M. M. (2010). Assessment of laboratory assays to measure rivaroxaban – an oral, direct factor Xa inhibitor. Thrombosis and Haemostasis. https://doi.org/10.1160/th09-03-0176

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.