CoChat

Effect of Glucagon-Like Peptide-1(7–36) and Exendin-4 on the Vascular Reactivity in Streptozotocin/Nicotinamide-Induced Diabetic Rats

Özyazgan, Sibel, Kutluata, Nilüfer, Afşar, Selim, Özdaş, Şule Beyhan, Akkan, Ahmet Gökhan · 2005 · Pharmacology
Cited by 55

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

We investigated the vascular effects of glucagon-like peptide-1 (GLP-1) and Exendin-4 in type 2 diabetic rat aortae. Studies were performed in a normal control group (NC) (0.2 ml i.p. saline, n = 10), streptozotocin (STZ)/nicotinamide diabetic control group (DC) (a single dose of 80 mg/kg STZ i.p. injection 15 min after administration of 230 mg/kg nicotinamide i.p.), GLP-1 (GLPC) control group (1 µg/kg twice daily i.p. for 1 month, n = 10), Exendin-4 control group (EXC) (0.1 µg/kg twice daily i.p. for 1 month, n = 10), GLP-1-treated diabetic group (GLPT) (1 µg/kg twice daily i.p. for 1 month, n = 10), and Exendin-4-treated diabetic group (EXT) (0.1 µg/kg twice daily i.p. for 1 month, n = 10). One month of GLP-1 and Exendin-4 treatment significantly decreased the blood glucose levels of diabetic rats (113 ± 2 mg/dl, p < 0.001, and 117 ± 1 mg/dl, p < 0.001, respectively versus 181 ± 9 mg/dl in the DC group). Sensitivity (pD 2) and maximum response (% Max. Relax) of acetylcholine-stimulated relaxations in the DC group (pD 2: 6.73 ± 0.12 and 55 ± 6, respectively) were decreased compared with the non-diabetic NC group (pD 2: 7.41 ± 0.25, p < 0.05, and 87 ± 4, p < 0.01). Treating diabetic rats with GLP-1, pD 2 values and with Exendin-4, Max. Relax %values of aortic strips to acetylcholine returned to near non-diabetic NC values (pD 2: 7.47 ± 0.15, p < 0.05, and 87 ± 3, p < 0.01, respectively). Maximal contractile responses (E max) to noradrenaline in aortic strips from the diabetic DC group (341 ± 27 mg tension/mg wet weight) were significantly decreased compared with the non-diabetic NC (540 ± 66 mg tension/mg wet weight, p < 0.001) and the GLPT group (490 ± 25 mg tension/mg wet weight, p < 0.05). There were no significant differences in pD 2 values of aortic strips to noradrenaline from all groups. E max to KCl in aortic strips from the DC group (247 ± 10 mg tension/mg wet weight, p < 0.01) was significantly decreased compared with non-diabetic NC group (327 ± 26 mg tension/mg wet weight). Treating diabetic rats with GLP-1 (GLPT), E max values of aortic strips to KCl returned to near non-diabetic NC values (271 ± 12 mg tension/mg wet weight). GLP-1 and (partially) Exendin-4 treatment could improve the increased blood glucose level and normalize the altered vascular tone in type 2 diabetic rats.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000084277

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Özyazgan, S., Kutluata, N., Afşar, S., Özdaş, Ş. B., & Akkan, A. G.
Venue
Pharmacology
Publisher
S. Karger AG
Published
2005
Volume
74
Issue
3
Pages
119-126
ISSN
  • 0031-7012 (ISSN-L)
  • 1423-0313
OpenAlex
W1977390245
Cited by
55
References
10
FWCI
1.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.