The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hardware-Related Complications of Deep Brain Stimulation: A Review of the Published Literature
Abstract
Hardware-related complications have been commonly described after deep brain stimulation. We searched the PubMed database using the key words ‘adverse effects’ and ‘deep brain stimulation’. Out of 254 studies, we identified 10 articles that primarily addressed morbidity and hardware-related adverse effects in 922 patients. The most commonly reported hardware-related complications were infections (6.1% of the patients), migration or misplacement of the leads (5.1% of the patients), lead fractures (5.0% of the patients), and skin erosion (1.3% of the patients). Refinements in surgical technique, technological improvements, and a greater experience with the procedures will likely decrease the incidence of hardware-related side effects in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients
Umemura, A., Jaggi, J. L., Hurtig, H. I., Siderowf, A. D., Colcher, A., Stern, M. B., & Baltuch, G. H. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0779 · Cited by 279
Research works printed but not linked: 16
- 10.1159%2F000070836 · DOI
- 10.1007%2Fs00701-005-0576-5 · DOI · Paper page
- 10.1136%2Fjnnp.2005.069161 · DOI
- 10.1002%2Fmds.10161 · DOI
- 10.1097%2F00006123-200206000-00017 · DOI · Paper page
- 10.1007%2Fs00701-004-0219-2 · DOI
- 10.1212%2F01.WNL.0000134650.91974.1A · DOI · Paper page
- 10.1159%2F000064600 · DOI · Paper page
- 10.1159%2F000075161 · DOI
- 10.1227%2F01.NEU.0000159714.28232.C4 · DOI · Paper page
- 10.1056%2FNEJMoa000827 · DOI · Paper page
- 10.1056%2FNEJMoa035275 · DOI · Paper page
- 10.1093%2Fbrain%2Fawh571 · DOI · Paper page
- 10.1016%2Fj.parkreldis.2004.10.011 · DOI
- 10.1136%2Fjnnp.2005.063206 · DOI · Paper page
- 10.1227%2F00006123-198712000-00017 · DOI · Paper page
Cited by
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Deep Brain Stimulation for Parkinson Disease: An Expert Consensus and Review of Key Issues
Bronstein, J. M., Tagliati, M., Alterman, R. L., Lozano, A. M., Volkmann, J., Stefani, A., Horak, F. B., Okun, M. S., Foote, K. D., Krack, P., et al. (2011) · Archives of Neurology · doi:10.1001/archneurol.2010.260 · Cited by 971
Self-citationCook, M. J., O'Brien, T. J., Berkovic, S. F., Murphy, M., Morokoff, A., Fabinyi, G., D'Souza, W., Yerra, R., Archer, J., Litewka, L., et al. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70075-9 · Cited by 879
MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study
Lipsman, N., Schwartz, M. L., Huang, Y., Lee, L., Sankar, T., Chapman, M., Hynynen, K., & Lozano, A. M. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70048-6 · Cited by 604
Self-citationNeuromodulation for chronic pain
Knotkova, H., Hamani, C., Sivanesan, E., Le Beuffe, M. F. E., Moon, J. Y., Cohen, S. P., & Huntoon, M. A. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00794-7 · Cited by 560
Self-citation
Metadata
- Authors
- Hamani, C., & Lozano, A. M.
- Venue
- Stereotactic and Functional Neurosurgery
- Publisher
- S. Karger AG
- Published
- 2006
- Volume
- 84
- Issue
- 5-6
- Pages
- 248-251
- ISSN
- 1011-6125 (ISSN-L)
- 1423-0372
- OpenAlex
- W2062932754
- Cited by
- 212
- References
- 1
- FWCI
- 8.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.karger.com/Services/SiteLicenses (vor)
- www.karger.com/Services/SiteLicenses (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hardware-Related Complications of Deep Brain Stimulation: A Review of the Published Literature. https://app.cochat.ai/papers/10.1159/000096499
- The paper
- Hamani, C., & Lozano, A. M. (2006). Hardware-Related Complications of Deep Brain Stimulation: A Review of the Published Literature. Stereotactic and Functional Neurosurgery. https://doi.org/10.1159/000096499
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.