The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Long-term Hardware-related Complications of Deep Brain Stimulation
Abstract
OBJECTIVE: To determine the incidence of long-term hardware-related complications of deep brain stimulation (DBS). METHODS: The study design is a retrospective chart review of a single-surgeon, single-institution experience with DBS in 84 consecutive cases from 1993 to 1999. Only patients with a minimum follow-up of 1 year were considered. Five patients were excluded because trial stimulation failed to achieve pain relief (n = 4) or because the procedure was aborted owing to hemorrhage (n = 1). Seventy-nine patients received 124 permanent DBS electrode implants. RESULTS: The mean follow-up period was 33 months, and the cumulative follow-up time was 217 patient-years or 310 electrode-years. Overall, 20 patients (25.3%) had 26 hardware-related complications involving 23 (18.5%) of the electrodes. There were 4 lead fractures, 4 lead migrations, 3 short or open circuits, 12 erosions and/or infections, 2 foreign body reactions, and one cerebrospinal fluid leak. The hardware-related complication rate per electrode-year was 8.4%. The most common complications were related to the electrode connectors. A significant finding was a high number of complications involving erosions or infections, which occurred in 7 of 12 instances as a late complication (beyond 12 mo). CONCLUSION: Long-term follow-up reveals that hardware-related complications occur in a significant number of patients. Factors that lead to such complications must be identified and addressed to maximize the important benefits of DBS therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Comparison of Continuous Thalamic Stimulation and Thalamotomy for Suppression of Severe Tremor
Schuurman, P. R., Bosch, D. A., Bossuyt, P. M. M., Bonsel, G. J., van Someren, E. J. W., de Bie, R. M. A., Merkus, M. P., & Speelman, J. D. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420703 · Cited by 1,044
Atlas for stereotaxy of the human brain
Bosch, D. A. (1978) · Clinical Neurology and Neurosurgery · doi:10.1016/s0303-8467(78)80027-4 · Cited by 867
Multicentre European study of thalamic stimulation in parkinsonian and essential tremor
Limousin, P., Speelman, J. D., Gielen, F., Janssens, M., & collaborators, S. (1999) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.66.3.289 · Cited by 491
High‐frequency unilateral thalamic stimulation in the treatment of essential and parkinsonian tremor
Koller, W., Pahwa, R., Busenbark, K., Hubble, J., Wilkinson, S., Lang, A., Tuite, P., Sime, E., Lazano, A., Hauser, R., et al. (1997) · Annals of Neurology · doi:10.1002/ana.410420304 · Cited by 478
Self-citationDeep Brain Stimulation for Intractable Pain: A 15-Year Experience
Kumar, K., Toth, C., & Nath, R. K. (1997) · Neurosurgery · doi:10.1097/00006123-199704000-00015 · Cited by 387
Long-Term Electrical Inhibition of Deep Brain Targets in Movement Disorders
Benabid, A. L., Benazzouz, A., Hoffmann, D., Limousin, P., Krack, P., & Pollak, P. (2008) · Movement Disorders · doi:10.1002/mds.870131321 · Cited by 375
Levy, R. M., Lamb, S., & Adams, J. E. (1987) · Neurosurgery · doi:10.1227/00006123-198712000-00017 · Cited by 319
Rezai, A. R., Lozano, A. M., Crawley, A. P., Joy, M. L. G., Davis, K. D., Kwan, C. L., Dostrovsky, J. O., Tasker, R. R., & Mikulis, D. J. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.3.0583 · Cited by 169
Self-citationTextbook of Stereotactic and Functional Neurosurgery
Staal, M. J. (1999) · Spinal Cord · doi:10.1038/sj.sc.3100743 · Cited by 135
Deep Brain Stimulator Electrodes Used for Lesioning: Proof of Principle
Oh, M. Y., Hodaie, M., Kim, S. H., et al. (2001) · Neurosurgery · doi:10.1097/00006123-200108000-00018 · Cited by 60
Self-citation
Cited by
Krack, P., Batir, A., Van Blercom, N., Chabardes, S., Fraix, V., Ardouin, C., Koudsie, A., Limousin, P. D., Benazzouz, A., LeBas, J. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035275 · Cited by 2,249
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Kaplitt, M. G., Feigin, A., Tang, C., Fitzsimons, H. L., Mattis, P., Lawlor, P. A., Bland, R. J., Young, D., Strybing, K., Eidelberg, D., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60982-9 · Cited by 1,067
Pahwa, R., Factor, S. A., Lyons, K. E., Ondo, W. G., Gronseth, G., Bronte-Stewart, H., Hallett, M., Miyasaki, J., Stevens, J., & Weiner, W. J. (2006) · Neurology · doi:10.1212/01.wnl.0000215250.82576.87 · Cited by 499
Metadata
- Authors
- Oh, M. Y., Abosch, A., Kim, S. H., Lang, A. E., & Lozano, A. M.
- Venue
- Neurosurgery
- Published
- 2002-06-01
- Volume
- 50
- Issue
- 6
- Pages
- 1268-1276
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2017863178
- Cited by
- 405
- References
- 11
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term Hardware-related Complications of Deep Brain Stimulation. https://app.cochat.ai/papers/10.1097/00006123-200206000-00017
- The paper
- Oh, M. Y., Abosch, A., Kim, S. H., Lang, A. E., & Lozano, A. M. (2002). Long-term Hardware-related Complications of Deep Brain Stimulation. Neurosurgery. https://doi.org/10.1097/00006123-200206000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.