The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
The ‘Double Lung Point’: An Ultrasound Sign Diagnostic of Transient Tachypnea of the Newborn
Abstract
Background: Transient tachypnea of the newborn (TTN) is a mild form of neonatal respiratory distress which early in its course needs to be differentiated from other severe respiratory disorders. At present the diagnosis is based on radiological findings and clinical course. Lung sonography in TTN has not yet been assessed. Objectives: The aim of the study was to define the ultrasonographic appearance of TTN and evaluate its clinical relevance. Methods: Lung sonography was performed in 32 newborn infants with radiological and clinical signs of TTN within the first hour after birth and the findings were compared with those of 60 normal infants, 29 with respiratory distress syndrome, 6 with pneumonia, 5 with pulmonary hemorrhage and 5 with atelectasis. Results: In the infants with TTN, lung sonography showed a difference in lung echogenicity between the upper and lower lung areas. There were very compact comet-tail artifacts in the inferior fields while these were rare in the superior fields. We designated this finding the ‘double lung point’ and it was not observed in healthy infants, infants with respiratory distress syndrome, actelectasis, pneumothorax, pneumonia, or pulmonary hemorrhage. Sensitivity and specificity of the double lung point was 100% for the diagnosis of TTN. Conclusion: We found lung sonography reliable for the early diagnosis of TTN. We suggest that it should become the first approach for imaging of neonatal respiratory distress although further prospective studies with good blinding need to be performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lichtenstein, D., Goldstein, I., Mourgeon, E., Cluzel, P., Grenier, P., & Rouby, J.-J. (2004) · Anesthesiology · doi:10.1097/00000542-200401000-00006 · Cited by 1,077
The Comet-tail Artifact: An Ultrasound Sign of Alveolar-Interstitial Syndrome
LICHTENSTEIN, D., MÉZIÈRE, G., BIDERMAN, P., GEPNER, A., & BARRÉ, O. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.5.96-07096 · Cited by 1,075
A Bedside Ultrasound Sign Ruling Out Pneumothorax in the Critically III
Lichtenstein, D. A., & Menu, Y. (1995) · Chest · doi:10.1378/chest.108.5.1345 · Cited by 787
Laing, W. A., Ogren, W. L., & Hageman, R. H. (1974) · Plant Physiology · doi:10.1104/pp.54.5.678 · Cited by 662
Ultrasound diagnosis of occult pneumothorax*
Lichtenstein, D. A., Mezière, G., Lascols, N., Biderman, P., Courret, J.-P., Gepner, A., Goldstein, I., & Tenoudji-Cohen, M. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000164542.86954.b4 · Cited by 632
Ultrasound diagnosis of alveolar consolidation in the critically ill
Lichtenstein, D. A., Lascols, N., Mezière, G., & Gepner, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2075-6 · Cited by 512
The comet-tail artifact: an ultrasound sign ruling out pneumothorax
Lichtenstein, D., Mezière, G., Biderman, P., & Gepner, A. (1999) · Intensive Care Medicine · doi:10.1007/s001340050862 · Cited by 466
The “lung pulse”: an early ultrasound sign of complete atelectasis
Lichtenstein, D. A., Lascols, N., Prin, S., & Mezière, G. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1930-9 · Cited by 372
Kendig's Disorders of the Respiratory Tract in Children
(2019) · Elsevier eBooks · doi:10.1016/c2015-0-01292-8 · Cited by 368
GLUCOCORTICOIDS INCREASE PULMONARY S-ADRENERGIC RECEPTORS IN FETAL RABBIT
Cheng, J. B., Goldfien, A., Ballard, P. L., & Roberts, J. M. (1980) · Endocrinology · doi:10.1210/endo-107-5-1646 · Cited by 126
Cited by
International evidence-based recommendations for point-of-care lung ultrasound
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS), Volpicelli, G., Elbarbary, M., Blaivas, M., Lichtenstein, D. A., Mathis, G., Kirkpatrick, A. W., Melniker, L., Gargani, L., Noble, V. E., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2513-4 · Cited by 2,874
Self-citationLung ultrasound in the critically ill
Lichtenstein, D. A. (2014) · Annals of Intensive Care · doi:10.1186/2110-5820-4-1 · Cited by 711
BLUE-Protocol and FALLS-Protocol
Lichtenstein, D. A. (2015) · Chest · doi:10.1378/chest.14-1313 · Cited by 691
Singh, Y., Tissot, C., Fraga, M. V., Yousef, N., Cortes, R. G., Lopez, J., Sanchez-de-Toledo, J., Brierley, J., Colunga, J. M., Raffaj, D., et al. (2020) · Critical Care · doi:10.1186/s13054-020-2787-9 · Cited by 659
Brat, R., Yousef, N., Klifa, R., Reynaud, S., Shankar Aguilera, S., & De Luca, D. (2015) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2015.1797 · Cited by 472
Metadata
- Authors
- Copetti, R., & Cattarossi, L.
- Venue
- Neonatology
- Publisher
- S. Karger AG
- Published
- 2006-12-06
- Volume
- 91
- Issue
- 3
- Pages
- 203-209
- ISSN
- 1661-7800 (ISSN-L)
- 1661-7819
- OpenAlex
- W2021028089
- Cited by
- 260
- References
- 13
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The ‘Double Lung Point’: An Ultrasound Sign Diagnostic of Transient Tachypnea of the Newborn. https://app.cochat.ai/papers/10.1159/000097454
- The paper
- Copetti, R., & Cattarossi, L. (2007). The ‘Double Lung Point’: An Ultrasound Sign Diagnostic of Transient Tachypnea of the Newborn. Neonatology. https://doi.org/10.1159/000097454
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.