Siddappa, Ashajyothi M., Rao, Raghavendra, Long, Jeffrey D., Widness, John A., Georgieff, Michael K.·2007·Neonatology

Abstract

Background: Serum ferritin measurements are used in clinical populations to estimate total body iron stores and the risk of subsequent iron deficiency or overload. The lack of normative newborn serum ferritin concentration data between 23 and 41 weeks has led to difficulty in establishing the incidence and degree of abnormal iron status in the neonatal period. Objectives: The primary objective of this review was to summarize the maternal and gestational factors that determine ferritin concentrations in full-term and pre-term newborn infants and to generate comprehensive reference values. The secondary objective was to assess serum ferritin concentrations in newborn infants at risk for abnormal fetal iron metabolism, including maternal diabetes mellitus, intrauterine growth restriction and maternal smoking during pregnancy. Methods: Serum ferritin and gestational age data at birth from 457 low-risk pre-term and term infants of 23–41 weeks gestation obtained from 35 published studies reviewed from a period of 25 years and from recently collected data from our centers were assessed by regression analysis. Slopes and intercepts of the high-risk groups were compared with the standard curve. Results: Umbilical cord serum ferritin concentrations increased with advancing gestational age, from a mean of 63 µg/l at 23 weeks to 171 µg/l at 41 weeks gestation (p < 0.001). The infants of diabetic mothers had a lower intercept than the control infants (p < 0.001). Conclusions: Iron deficiency and overload have been implicated in neurodevelopmental impairments. Normative cord serum ferritin data may permit a more precise assessment of infants who are at risk for abnormal iron status at birth.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000100805

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 59 references

Cited by

See all 294

Metadata

Authors
Siddappa, A. M., Rao, R., Long, J. D., Widness, J. A., & Georgieff, M. K.
Venue
Neonatology
Publisher
S. Karger AG
Published
2007
Volume
92
Issue
2
Pages
73-82
ISSN
  • 1661-7800 (ISSN-L)
  • 1661-7819
OpenAlex
W1999291738
Cited by
294
References
59
FWCI
4.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Assessment of Newborn Iron Stores at Birth: A Review of the Literature and Standards for Ferritin Concentrations. https://app.cochat.ai/papers/10.1159/000100805
The paper
Siddappa, A. M., Rao, R., Long, J. D., Widness, J. A., & Georgieff, M. K. (2007). The Assessment of Newborn Iron Stores at Birth: A Review of the Literature and Standards for Ferritin Concentrations. Neonatology. https://doi.org/10.1159/000100805

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.