A Comparative Evaluation of Various Methods for Microalbuminuria Screening
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Background/Aims: Microalbuminuria is a marker of abnormal vascular response and a predictor of cardiovascular morbidity and mortality. We evaluated a new quantitative office-based method to assess urinary albumin excretion (UAE) and compared it to other established methods. Methods: Spot urine samples from 165 patients were analyzed at a single study site using the HemoCue system, Clinitek Microalbumin, and Chemstrip Micral test, as well as at a central laboratory, where UAE and creatinine levels were measured. The central laboratory UAE values were used as reference. We evaluated the validity of the HemoCue results and compared them to the respective data for the laboratory albumin-to-creatinine ratio (ACR). Additionally, we assessed, diagnostic sensitivity, specificity, and positive and negative predictive values of all four methods, as well as the reproducibility of the HemoCue measurements. Results: Linear regression analysis demonstrated a good correlation for the HemoCue system (y = 0.9978x – 1.0217, R 2 = 0.904) and ACR (y = 0.0815x + 0.3373, R 2 = 0.784). Sensitivity and specificity for microalbuminuria diagnosis were 92 and 98% for HemoCue, 73 and 96% for ACR, 100 and 81% for Clinitek Microalbumin, and 70 and 83% for Chemstrip Micral dipstick, respectively. The correlation coefficient of duplicate HemoCue measurements was r = 0.98 (p < 0.001). Conclusions: The HemoCue system for microalbuminuria detection was as accurate and precise as laboratory ACR estimations. Its diagnostic performance was much better than that of widely used dipstick methods.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For the latter, tests to detect low concentrations of albumin are used (453-455).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [455]
In the citing paper
“One dipstick was found to have .95%sensitivity (322,324).”
From Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus (2011) · cites this paper as [324]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Levey, A. S., Coresh, J., Bolton, K., Culleton, B. F., Harvey, K. S., Ikizler, T. A., Johnson, C. A., Kausz, A., Kimmel, P. L., Kusek, J. W., et al. (2002) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 11,633
(2004) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2004.03.003 · Cited by 1,245
American Diabetes Association (2004) · Diabetes Care · doi:10.2337/diacare.27.2007.s79 · Cited by 1,042
Antihypertensive Therapy in the Presence of Proteinuria
Sarafidis, P. A., Khosla, N., & Bakris, G. L. (2007) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2006.10.014 · Cited by 364 · cited 1×
“Microalbuminuria is now widely recognized as a sign of abnormal vascular function and increased vascular permeability [ ,”
BackgroundSelf-citationUse of the Albumin/Creatinine Ratio to Detect Microalbuminuria: Implications of Sex and Race
Mattix, H. J., Hsu, C.-Y., Shaykevich, S., & Curhan, G. (2002) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1341034 · Cited by 355
Jacobs, D. R. (2002) · American Journal of Epidemiology · doi:10.1093/aje/155.12.1114 · Cited by 121 · cited 1×
“At the central laboratory (Quest Diagnostics), urinary albumin was measured using an immunoturbidimetric method, and creatinine was measured with a kinetic modification of the Jaffe method on an Olympus analyzer (Olympus Life and Material Science Europe, Hamburg, Germany). The ACR ratio (mg/mmol) was calculated by div…”
MethodInfluentialMicroalbuminuria and chronic kidney disease as risk factors for cardiovascular disease
Sarafidis, P. A., & Bakris, G. L. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfl309 · Cited by 112 · cited 1×
“In addition, accumulating evidence suggests that microalbuminuria is associated with a higher cardiovascular risk as well as with a higher mortality independent of other risk factors [”
BackgroundSelf-citationHow Long Should Insulin Be Used Once a Vial Is Started?
Molitch, M. E. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1240-a · Cited by 90
Cited by
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Self-citationSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Self-citationSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
“In a separate study, 165 patients had the HemoCue point-ofcare system for albumin compared with the Clinitek Microalbumin (Siemens) and Chemstrip Micral (Roche Diagnostics) tests, as well as with an HPLC assay, for spot albumin–creatinine ratio measurement (324).”
Self-citationScreening for CKD with eGFR: Doubts and Dangers
Glassock, R. J., & Winearls, C. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.00960208 · Cited by 178
“Accurate, reliable, inexpensive, and rapid point-of-service methods or devices that measure low, but abnormal levels of albumin excretion are now available and studies are in progress to better define their value in the overall screening paradigm ( 27 ).”
BackgroundMYH9 and APOL1 are both associated with sickle cell disease nephropathy
Ashley‐Koch, A. E., Okocha, E. C., Garrett, M. E., Soldano, K., De Castro, L. M., Jonassaint, J. C., Orringer, E. P., Eckman, J. R., & Telen, M. J. (2011) · British Journal of Haematology · doi:10.1111/j.1365-2141.2011.08832.x · Cited by 160
“Despite the availability of more accurate methods of detecting proteinuria, the sensitivity and specificity of dipstick to detect microalbuminuria has been estimated to be 70% and 83%, respectively (Sarafidis et al, 2008).”
MethodSacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
“In a separate study, 165 patients had the HemoCue point-ofcare system for albumin compared with the Clinitek Microalbumin (Siemens) and Chemstrip Micral (Roche Diagnostics) tests, as well as with an HPLC assay, for spot albumin–creatinine ratio measurement (324).”
Self-citationIs the Presence of Microalbuminuria a Relevant Marker of Kidney Disease?
Glassock, R. J. (2010) · Current Hypertension Reports · doi:10.1007/s11906-010-0133-3 · Cited by 150
“amounts of albumin make assessment of MA readily available, reliable, and inexpensive [7].”
BackgroundA Health Policy Model of CKD: 2. The Cost-Effectiveness of Microalbuminuria Screening
Hoerger, T. J., Wittenborn, J. S., Segel, J. E., Burrows, N. R., Imai, K., Eggers, P. W., Pavkov, M. E., Jordan, R., Hailpern, S. M., Schoolwerth, A. C., et al. (2010) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2009.11.017 · Cited by 146
Peralta, C. A., Norris, K. C., Li, S., Chang, T. I., Tamura, M. K., Jolly, S. E., Bakris, G., McCullough, P. A., Shlipak, M., & KEEP Investigators, F. T. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.619 · Cited by 132
“001 Non-Hispanic black 1118 (21) 804 (24) 787 (27) 1331 (30) Non-Hispanic Asian 224 (4) 136 (4) 101 (3) 130 (3) Non-Hispanic other 289 (5) 169 (5) 140 (5) 178 (4) Hispanic 317 (6) 210 (6) 158 (5) 272 (6) Family history of kidney disease 848 (17) 568 (17) 487 (17) 740 (17) .”
Self-citationRani, P. K., Raman, R., Gupta, A., Pal, S. S., Kulothungan, V., & Sharma, T. (2011) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-3-9 · Cited by 97
“The diagnostic performance of measuring UAC in a spot morning urine sample in predicting microalbuminuria in subsequent 24-hour urine collections has been reported to be satisfactory, and, moreover, comparable to that of measuring ACR [19].”
MethodMethods of albumin estimation in clinical biochemistry: Past, present, and future
Kumar, D., & Banerjee, D. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2017.04.007 · Cited by 104
Epidemiology of Masked and White-Coat Hypertension: The Family-Based SKIPOGH Study
Alwan, H., Pruijm, M., Ponte, B., Ackermann, D., Guessous, I., Ehret, G., Staessen, J. A., Asayama, K., Vuistiner, P., Younes, S. E., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0092522 · Cited by 73
“Albuminuria was defined as a urinary albumin excretion $ 20 mg/min [35].”
BackgroundThe Landscape of Diabetic Kidney Disease in the United States
Duru, O. K., Middleton, T. R., Tewari, M. K., & Norris, K. C. (2018) · Current Diabetes Reports · doi:10.1007/s11892-018-0980-x · Cited by 82
Health economic modelling of the cost-effectiveness of microalbuminuria screening in Switzerland
Kessler, R., Keusch, G. W., Szucs, T. D., Wittenborn, J. S., Hoerger, T. J., Brügger, U., & Wieser, S. (2012) · Swiss Medical Weekly · doi:10.4414/smw.2012.13508 · Cited by 64
Initiative, O. B. O. T. C. F. D. C. A. P. C., Yarnoff, B. O., Hoerger, T. J., Simpson, S. K., Leib, A., Burrows, N. R., Shrestha, S. S., & Pavkov, M. E. (2017) · BMC Nephrology · doi:10.1186/s12882-017-0497-6 · Cited by 55
Graziani, M. S., Gambaro, G., Mantovani, L., Sorio, A., Yabarek, T., Abaterusso, C., Lupo, A., & Rizzotti, P. (2009) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfn639 · Cited by 54
Cost-Effectiveness of Screening for Microalbuminuria among African Americans
Hoerger, T. J., Wittenborn, J. S., Zhuo, X., Pavkov, M. E., Burrows, N. R., Eggers, P. W., Jordan, R., Saydah, S., & Williams, D. E. (2012) · Journal of the American Society of Nephrology · doi:10.1681/asn.2012040347 · Cited by 44
Marateb, H. R., Mansourian, M., Faghihimani, E., Amini, M., & Farina, D. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.11.006 · Cited by 50
Urinary biomarkers and nephrotoxicity
Finn, W. F., & Porter, G. A. (2008) · Springer eBooks · doi:10.1007/978-0-387-84843-3_6 · Cited by 37
Nagrebetsky, A., Jin, J., Stevens, R., James, T. J., Adler, A., Park, P., Craven, A., Shine, B. S. F., & Farmer, A. A. (2012) · Family Practice · doi:10.1093/fampra/cms057 · Cited by 38
Point-of-care testing technologies for the home in chronic kidney disease: a narrative review
Bodington, R., Kassianides, X., & Bhandari, S. (2021) · Clinical Kidney Journal · doi:10.1093/ckj/sfab080 · Cited by 37
“methods Sarafidis (2008) [51]: n1⁄4165; diagnosis of microalbuminuria us-”
MethodScreening for Nephropathy in Diabetes Mellitus: Is Micral-Test Valid among All Diabetics?
Afifa, K., Sriha, A. B., Nabil, H., Ahlem, B., Mounira, S., Kawthar, Y., Triki, S., Hellara, I., Fadoua, N., Fadhel, N. M., et al. (2016) · International Journal of Chronic Diseases · doi:10.1155/2016/2910627 · Cited by 21
“Several studies have shown that the MT is commonly used worldwide, that it is a good screening tool for MA [32, 33, 36, 37, 39], and that positive results should be confirmed and quantified by a reference assay [33, 36].”
BackgroundYoon, Y. E., Lee, K. S., Choi, K. H., Kim, K. H., Yang, S. C., & Han, W. K. (2014) · The Journal of Urology · doi:10.1016/j.juro.2014.03.106 · Cited by 12
“Now, microalbuminuria (MA) is more frequently measured because precise and simple methods for estimating microalbumin in urine are available.(3) This is usually expressed as the urinary albumin-to-creatinine ratio (UACR) to compensate for hydration status.”
MethodMonitoring and Managing Urinary Albumin Excretion: Practical Advice for Primary Care Clinicians
Bakris, G. L., & Kuritzky, L. (2009) · Postgraduate Medicine · doi:10.3810/pgm.2009.07.2031 · Cited by 12
Self-citationPractical Aspects of Calculation, Expression and Interpretation Of Urine Albumin Measurement -
Chavan, V. U., Sayyed, A. K., Durgawale, P., Sontakke, A. V., & Nilakhe, S. D. (2011) · National journal of integrated research in medicine · Cited by 11
Evaluation of point-of-care tests for detecting microalbuminuria in diabetic patients
Lloyd, M., Kuyl, J. M., & van Jaarsveld, H. (2011) · South African Family Practice · doi:10.1080/20786204.2011.10874100 · Cited by 12
Plasma Volume Expanders: Use in Medicine and Detecting Misuse in Sports
Simoni, R. E., Scalco, F. B., de Oliveira, M. L. C., & Neto, F. R. D. A. (2011) · Bioanalysis · doi:10.4155/bio.10.181 · Cited by 8
Chavan, V. U., Durgawale, P., Sayyed, A. K., Sontakke, A. V., Attar, N., Patel, S., Patil, S. R., & Nilakhe, S. D. (2011) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-011-0136-0 · Cited by 8
“Microalbuminuria is currently defined as a urinary albumin excretion (UAE) of 30–300 mg/24 h, if measured in a 24-h urine collection, in spot urine samples urinary albumin concentration (UAC) of 20–200 mg/l [18] and albumin: creatinine ratio (ACR) of 30–300 mg/g, in both men and women [19].”
BackgroundMethodDevi, L. T., & Nimonkar, A. R. (2018) · International Journal of Reproduction Contraception Obstetrics and Gynecology · doi:10.18203/2320-1770.ijrcog20184133 · Cited by 5
“Microalbuminuria is currently defined as a urinary albumin excretion (UAE) of 30 to 300 mg/24 hours, if measured in a 24-hour urine collection, as urinary albumin excretion rate (AER) of 20 to 200 μg/min, if measured in a timed urine collection, or of 30 to 300 mg/g, if measured with the use of the urinary albumin: cr…”
MethodCapelli, I., Benedictis, M. D., Lenarda, A. D., Maso, V. D., Fabbrini, P., Gallì, P., Garofalo, C., Leone, A. M., Maiorino, M. I., Marengo, M., et al. (2025) · Journal of Nephrology · doi:10.1007/s40620-025-02371-w · Cited by 6
Prevalence of Renal Disease in Human Immunodeficiency Virus-Infected Children in Calabar, Nigeria
Nsa, E., Uzomba, C. I., Etuk, I. S., & Anah, M. U. (2022) · Saudi Journal of Kidney Diseases and Transplantation · doi:10.4103/1319-2442.374380 · Cited by 3
Research Aspects and Strategies for the Development of Biosensors for Renal Disease Diagnosis
Srivastava, A., & Agarwal, G. (2021) · Springer eBooks · doi:10.1007/978-981-16-2782-8_7 · Cited by 2
The point-of-care testing in diabetology
Matteucci, E., & Giampietro, O. (2011) · Clinical Management Issues · doi:10.7175/cmi.v5i3.503 · Cited by 1
Multi‐compartment metabolic assessment of the kidneys by co‐hyperpolarized 13C MRI
von Morze, C., Shaw, A., Shoghi, K. I., & Blazey, T. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30568 · Cited by 1
Prevalence of and clinical characteristics associated with microalbuminuria in hypertension
Alharf, A. (2012) · Enlighten: Theses (The University of Glasgow) · Cited by 2
Ibrahim, H. O. (2015) · SUNScholar (Stellenbosch University)
ESTIMATION OF MICROALBUMIN IN TYPE – 2 DIABETES MELLITUS
Radhakishan, N., Naveen Kumar, T., Neetha, K., & Srilatha, B. (2014) · Journal of Evolution of Medical and Dental Sciences · doi:10.14260/jemds/2014/1877
Tytus, R. H., Burgess, E. D., Maurer, J., & Vanjaka, A. (2013) · Clinical Drug Investigation · doi:10.1007/s40261-013-0092-y
Microalbuminuria and Kidney Disease: An Evidence-based Perspective
Kalaitzidis, R., Dalal, P., & Bakris, G. L. (2010) · Springer eBooks · doi:10.1007/978-88-470-1463-3_9
“Point of care testing is now available using a spot urine to assess presence and magnitude of MA and is used in screening programs around the world [ 9 , 10].”
MethodSelf-citationМаксимюк, Г. В. (2026) · Medical and Clinical Chemistry · doi:10.11603/mcch.2410-681x.2026.i3.16533
Metadata
- Authors
- Sarafidis, P. A., Riehle, J., Bogojevic, Z., Basta, E., Chugh, A., & Bakris, G. L.
- Affiliations
- Rush University Medical Center (US)
- University of Chicago (US)
- Venue
- American Journal of Nephrology
- Publisher
- S. Karger AG
- Published
- 2007-11-29
- Volume
- 28
- Issue
- 2
- Pages
- 324-329
- ISSN
- 0250-8095 (ISSN-L)
- 1421-9670
- OpenAlex
- W1993678470
- Cited by
- 41
- References
- 14
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 2 · 2018: 2 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 2 · 2012: 5
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.karger.com/Services/SiteLicenses (vor)
- www.karger.com/Services/SiteLicenses (tdm)
- Locations
- American Journal of Nephrology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Quest Diagnostics
- Bayer HealthCare
- Topics
- Health Sciences › Medicine › Nephrology › Chronic Kidney Disease and Diabetes
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- microalbuminuria, urinary albumin excretion, HemoCue, albumin-creatinine ratio, spot urine, diagnostic accuracy, measurement reproducibility, cardiovascular risk
- MeSH terms
- Adult, Aged, Albuminuria, Diabetes Mellitus, Female, Humans, Hypertension, Kidney Diseases, Male, Mass Screening, Middle Aged, Predictive Value of Tests, Reagent Strips, Reproducibility of Results, Urinalysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.