Impact of Delayed Arterial Cord Blood Sampling for Lactate Assay
The DOI matches its Crossref record, with a small difference in title or year; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Background: Umbilical cord sampling at delivery provides important data on the newborn’s metabolism. Objective: To evaluate the impact of delayed sampling on arterial cord blood lactate values. Methods: Observational study of 168 consecutive deliveries at a tertiary teaching hospital. Arterial cord blood lactate was determined with a test strip method on paired samples obtained immediately and 5–30 min after birth. At least 90 paired measurements were necessary to show a difference in lactate levels of ≥0.5 mmol/l between the first and second samples. Lactate levels according to the time interval between birth and sampling. Results: One hundred and two paired samples were available for analysis. The lactate value was always higher in the second sample than in the first. Lactate levels increased linearly with time, by 0.062 mmol/l per min. The degree of increase was independent of the initial lactate level and the route of delivery. Delayed sampling resulted in abnormal lactate levels in 16% of neonates born with normal lactate levels. Conclusions: Our results show that delayed sampling of arterial cord blood is unreliable for neonatal lactate assay. Cord blood sampling and lactate assay should therefore be performed immediately after delivery.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In double-clamped cords, the arterial lactate concentration increases linearly with time, and a 10-minute delay of analysis will result in an approximately 0.6 mmol/L higher value, irrespective of mode of delivery and initial value.69,71”
From Umbilical cord pH, blood gases, and lactate at birth: normal values, interpretation, and clinical utility. (2023) · cites this paper as [71]
Citations
Cites
MacLennan, A. (1999) · BMJ · doi:10.1136/bmj.319.7216.1054 · Cited by 731
Blood gases, pH, and lactate in appropriate- and small-for-gestational-age fetuses
Nicolaides, K. H., Economides, D. L., & Soothill, P. W. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90770-9 · Cited by 390
Routine umbilical cord blood gas determinations?
Thorp, J. A., Sampson, J. E., Parisi, V. M., & Creasy, R. K. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90362-1 · Cited by 150
Clinical value of a single postnatal lactate measurement after intrapartum asphyxia
da Silva, S., Hennebert, N., Denis, R., & Wayenberg, J. (2000) · Acta Paediatrica · doi:10.1111/j.1651-2227.2000.tb01334.x · Cited by 115
Routine measurements of umbilical artery lactate levels the prediction of perinatal outcome
Westgren, M., Divon, M. Y., Horal, M., Ingemarsson, I., Kublickas, M., Shimojo, N., & Nordström, L. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)90627-4 · Cited by 104
Umbilical cord blood gas analysis at delivery
Thorp, Dildy, G. A., Yeomans, Meyer, & Parisi (1996) · American Journal of Obstetrics and Gynecology · doi:10.1053/ob.1996.v175.a74401 · Cited by 99
Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood
Shimojo, N., Naka, K., Uenoyama, H., Hamamoto, K., Yoshioka, K., & Okuda, K. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.11.2312 · Cited by 90
The case for routine umbilical blood acid-base studies at delivery
Johnson, J. W., RICHARDS, D. S., & Wagaman, R. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)90970-i · Cited by 60
A practical approach to umbilical artery pH and blood gas determinations.
Duerbeck, N. B., Chaffin, D. G., & Seeds, J. W. (1992) · PubMed · Cited by 57
Fetal scalp and cord blood lactate
Nordström, L. (2004) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2004.02.006 · Cited by 48
Quality assessment of two lactate test strip methods suitable for obstetric use
Nordström, L., Chua, S., Roy, A. C., & Arulkumaran, S. (1998) · Journal of Perinatal Medicine · doi:10.1515/jpme.1998.26.2.83 · Cited by 47
Chou, Y., Yau, K.-I. T., & Wang, P. (1998) · Acta Paediatrica · doi:10.1080/080352598750013851 · Cited by 47
Armstrong, L., & Stenson, B. (2006) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/adc.2005.086744 · Cited by 45 · cited 1×
“In contrast, little is known of the influence of the sampling time on the measured lactate concentration. In a small series of elective Cesarean sections, Armstrong and Stenson [”
BackgroundGroenendaal, F., Lindemans, C. A., Uiterwaal, C. S. P. M., & de Vries, L. S. (2003) · Neonatology · doi:10.1159/000068927 · Cited by 41
Nordström, L., Ingemarsson, I., Persson, B., Shimojo, N., & Westgren, M. (1994) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016349409023449 · Cited by 33
Cheung, P., Robertson, C. M. T., & Finer, N. N. (1996) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.74.1.f47 · Cited by 32
Effect of delays in collection or analysis on the results of umbilical cord blood measurements
SYKES, G. S., & MOLLOY, P. M. (1984) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1984.tb03676.x · Cited by 27
Cord Lactate, pH, and Blood Gases from Healthy Neonates
Shirey, T., Pierre, J. S., & Wirikelman, J. (2010) · Gynecologic and Obstetric Investigation · doi:10.1159/000292027 · Cited by 26
Sequential changes in placental blood gases and pH during the hour following delivery.
Hilger, J. S., Holzman, I. R., & Brown, D. R. (1981) · PubMed · Cited by 22
Cord and placenta arterial gas analysis: the accuracy of delayed sampling
Lynn, A., & Beeby, P. (2006) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/adc.2006.103358 · Cited by 20
[Lactate measurements and acid-base balance in cord blood].
Martin, A., Gaillard, M., Miot, S., Riethmuller, D., & Schaal, J. P. (2003) · PubMed · Cited by 11
Questioning the Practice of Routine Umbilical Cord Blood pH Sampling at Delivery
Perkins, R. P., Weaver, P. A., & Sweeney, W. J. (1993) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767059309017340 · Cited by 7
Research works printed but not linked: 3
- 10.1136%2Fadc.74.1.47 · DOI
- 10.1080%2F080352500750028465 · doi:10.1080/080352500750028465 · Paper page
- 10.1016%2FS0020-7292%2896%2990022-3 · DOI
Cited by
Olofsson, P. (2023) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.07.001 · Cited by 104
Effect of delayed umbilical cord clamping on blood gas analysis
Sanz, J. L. V., Real, D. D., Perales‐Puchalt, A., Rubio, J., Diago, V., & Perales, A. (2012) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2012.01.020 · Cited by 65
Orsonneau, J., Fraissinet, F., Sebille, V., Dudouet, D., & Bigot‐Corbel, E. (2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0201 · Cited by 21
White, C. R. H., Mok, T., Doherty, D. A., Henderson, J., Newnham, J. P., & Pennell, C. E. (2011) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2011.596959 · Cited by 16
Sadiq, M. (2020) · Cited by 5
Metadata
- Authors
- Dessolle, L., Lebrec, J., & Daraï, E.
- Affiliations
- Centre Hospitalier des Pays de Morlaix (FR)
- Venue
- Neonatology
- Publisher
- S. Karger AG
- Published
- 2008-10-27
- Volume
- 95
- Issue
- 3
- Pages
- 224-229
- ISSN
- 1661-7800 (ISSN-L)
- 1661-7819
- OpenAlex
- W1964586532
- Cited by
- 17
- References
- 22
- Citations by year
- 2026: 3 · 2025: 2 · 2023: 2 · 2020: 1 · 2019: 1 · 2014: 1 · 2013: 3 · 2012: 2
- FWCI
- 0.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.karger.com/Services/SiteLicenses (vor)
- www.karger.com/Services/SiteLicenses (tdm)
- Locations
- Neonatology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Metabolism and Genetic Disorders
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Neonatal Health and Biochemistry
- Keywords
- neonatal acid-base status
- MeSH terms
- Birth Weight, Blood Specimen Collection, Fetal Blood, Hospitals, Teaching, Humans, Infant, Newborn, Prospective Studies, Reagent Strips, Time Factors, Reproducibility of Results, Lactic Acid, Delivery, Obstetric
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.