CoChat

Home Blood Pressure Measurements for Managing Hypertension in Hemodialysis Patients

Open access
Agarwal, Rajiv, Satyan, Sangeetha, Alborzi, Pooneh, Light, Robert P., Tegegne, Getachew G., Mazengia, Helmneh S., Yigazu, Paulos M. · 2009 · American Journal of Nephrology
Cited by 79

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Home blood pressure (BP) monitoring serves as a practical method to detect changes in BP instead of ambulatory BP monitoring in hemodialysis patients. To evaluate the relationship of reduction in home BP compared to interdialytic ambulatory BP measurements we analyzed the data from the dry-weight reduction in hypertensive hemodialysis patients (DRIP) trial in which 100 patients had their dry weight probed based on clinical sign and symptoms and 50 patients served as controls. We measured home BP 3 times a day for 1 week using a validated oscillometric monitor on 3 occasions at 4-week intervals after randomization. Changes from baseline in home, predialysis BP and postdialysis BP were compared to interdialytic 44-hour ambulatory BP. Home and ambulatory BP monitoring was available in 141 of 150 (94%) patients. Predialysis systolic BP was not as sensitive as ambulatory BP in detecting change in BP with dry-weight reduction. Whereas postdialysis BP was capable of detecting an improvement in systolic BP in response to probing dry weight, by itself it does not provide evidence that change in postdialysis BP persists over the interdialytic period. Home BP reliably detected changes in ambulatory BP, albeit with less sensitivity at 4 weeks. However, at 4 and at 8 weeks, changes in home systolic BP were most strongly related to changes in interdialytic ambulatory systolic BP compared to predialysis and postdialysis BP. The reproducibility of BP measurements followed the order home > ambulatory >> predialysis > postdialysis. These data provide support for the use of home BP monitoring for the management of hypertension in hemodialysis patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000206698

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 79

Metadata

Authors
Agarwal, R., Satyan, S., Alborzi, P., Light, R. P., Tegegne, G. G., Mazengia, H. S., & Yigazu, P. M.
Venue
American Journal of Nephrology
Publisher
S. Karger AG
Published
2009
Volume
30
Issue
2
Pages
126-134
ISSN
  • 0250-8095 (ISSN-L)
  • 1421-9670
OpenAlex
W2047000362
Cited by
79
References
8
FWCI
3.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Home Blood Pressure Measurements for Managing Hypertension in Hemodialysis Patients. https://app.cochat.ai/papers/10.1159/000206698
The paper
Agarwal, R., Satyan, S., Alborzi, P., Light, R. P., Tegegne, G. G., Mazengia, H. S., & Yigazu, P. M. (2009). Home Blood Pressure Measurements for Managing Hypertension in Hemodialysis Patients. American Journal of Nephrology. https://doi.org/10.1159/000206698

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.