Cited by 40Systemic Lupus Erythematosus ResearchBlood Coagulation and Thrombosis MechanismsClinical Laboratory Practices and Quality Control

Sensitivity of Sixteen APTT Reagents for the Presence of Lupus Anticoagulants

Open access
Denis-Magdelaine, A., Flahault, A., Verdy, E.·2009·Haemostasis

Abstract

Activated partial thromboplastin time (APTT) is the most common assay used to screen for lupus anticoagulant (LA). For some years, manufacturers have been proposing APTT reagents that were more sensitive to LA. In this study, we evaluated the sensitivity and responsiveness of 16 APTT reagents in 40 LA and 46 normal plasmas. Sensitivity was established using a 1:1 mixture of normal and LA plasma that optimized the most sensitive reagent. The same pool of normal plasma was used for the assay of mixtures and daily APTT values for the determination of ratios. The results show that new commercially available APTT reagents are more sensitive and responsive to LA. The different sensitivities of APTT reagents might be partly due to the heterogeneity of LAs and several APTT reagents should be used for LA detection. The choice of APTT reagents constitutes an important preliminary step for LA evaluation.

Integrity signals

Registry

Crossref · 10.1159/000217148

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Denis-Magdelaine, A., Flahault, A., & Verdy, E.
Affiliations
Hôpital Tenon (FR)
Venue
Haemostasis
Publisher
S. Karger AG
Published
2009-04-28
Volume
25
Issue
3
Pages
98-105
ISSN
  • 0301-0147 (ISSN-L)
  • 1423-0038
OpenAlex
W2066577438
Cited by
40
References
0
Citations by year
2025: 1 · 2022: 1 · 2020: 2 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 2 · 2014: 3 · 2013: 1 · 2012: 5
FWCI
2.59
Type
journal article
Language
en
Open access
Locations
  • Haemostasis (publishedVersion)
  • PubMed (publishedVersion)
  • Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
lupus anticoagulant, activated partial thromboplastin time, assay sensitivity, anticoagulant screening, reagent selection
MeSH terms
Adolescent, Adult, Aged, Aged, 80 and over, Blood Coagulation Tests, Female, Humans, Indicators and Reagents, Lupus Erythematosus, Systemic, Male, Middle Aged, Partial Thromboplastin Time, Sensitivity and Specificity, Case-Control Studies, Lupus Coagulation Inhibitor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review