Ruling out lupus anticoagulants with mixing test-specific cutoff assessment and the index of circulating anticoagulant

Open access
Kumano, Osamu, Moore, Gary W.·2019·Research and Practice in Thrombosis and Haemostasis

Abstract

BACKGROUND: Lupus anticoagulant (LA) is classified in the antibody family that is recognized in antiphospholipid syndrome. Mixing tests are recommended for LA detection, and either a mixing test-specific cutoff (MTC) or index of circulating anticoagulant (ICA) is used for the interpretation. Although we previously showed MTC had higher sensitivity for LA than ICA, there are few studies investigating specificity. OBJECTIVES: To investigate specificity of multiple activated partial thromboplastin time (APTT) and diluted Russell's viper venom time (dRVVT) reagents for inhibitors using plasmas with non-LA causes of prolonged clotting times, interpreted with MTC and ICA. METHODS: Seventy-six factor-deficient samples (either artificially prepared, hereditary deficiency, or warfarin), and 12 inhibitors (either coagulation factor inhibitors, rivaroxaban, or apixaban) were used. Samples were tested with 4 APTTs, 1 dilute APTT (dAPTT), and 2 dRVVT reagents, and all elevated screen ratios were followed up with mixing tests. Frequencies of corrected and not-corrected results were calculated. RESULTS: The frequency of MTC and ICA corrected results, suggesting factor deficiency, were 5% to 43% and 79% to 100%, respectively, except for dAPTT, where MTC and ICA performed similarly. Frequencies of MTC and ICA not-corrected results, suggesting inhibition, were 29% to 100% and 25% to 67%, respectively. CONCLUSIONS: The data indicate that MTC has a tendency to generate not-corrected mixing tests in factor-deficient, warfarin, and other inhibitor samples, while ICA exhibited higher specificity. When we perform the mixing test and interpret the data, it is important to understand the characteristics of the indexes for maximizing the diagnostic potential of mixing test.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rth2.12245

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The mixing test normalized ratio is most sensitive to inhibitors.

    “The mixing test normalized ratio showed non-correction in all LA samples, indicating that this index is most sensitive to inhibitors”

    From Performance characteristics of 5 numerical indexes in mixing test interpretation under coexistence of lupus anticoagulant and coagulation factor deficiency (2023) · cites this paper as [7]

    The Introduction reports that the mixing test–specific cutoff (based on the mix ratio) was more sensitive to lupus anticoagulants than the index of circulating anticoagulant. The Results also found more frequent inhibitor detection with that cutoff for most, but not all, reagents. This paper does not report non-correction in all lupus anticoagulant samples or establish that the ratio is the most sensitive index overall. (LLM, conf=0.85)

    Experimental — accuracy not yet measured
  • Mixing tests are performed to improve the specificity of LA detection and rule out other causes of prolonged clotting time, including coagulation factor deficiency, anticoagulant use, and coagulation factor inhibitors.

    “Mixing tests are performed to improve the specificity of LA detection and rule out other causes of prolonged clotting time (CT), including coagulation factor deficiency, anticoagulant use, and coagulation factor inhibitors [15,16].”

    From Comparison of different algorithms for lupus anticoagulant detection: a single-center experience (2024) · cites this paper as [16]

    The Introduction says mixing tests help distinguish inhibitors from factor deficiencies, and the Discussion reports that ICA improves specificity when investigating non-LA causes of prolonged clotting time. But the Discussion also says mixing tests are not specific for LA-induced inhibition: factor inhibitors and direct anticoagulants can affect their results, and confirmatory tests are needed. Thus the source does not support saying mixing tests rule out all the listed causes. (LLM, conf=0.88)

    Experimental — accuracy not yet measured
  • ICA has a high specificity to factor deficiency, whereas the mixing test ratio has a high sensitivity to inhibitors.

    “For instance, ICA has a high specificity to factor deficiency, whereas the mixing test ratio has a high sensitivity to inhibitors [6,7], although both indexes are recommended for LA diagnosis [8,9].”
  • MTC and ICA can be calculated and employed as interpretation indices for mixing tests.

    “In addition, the mixing test–specific cutoff (MTC) and index of circulating anticoagulant (ICA) can be calculated and employed as interpretation indices for the mixing tests [[15], [16], [17], [18], [19]].”
  • Using mixing tests interpreted with ICA demonstrates superior specificity as there are few false positives of inhibition by non-LA causes in cases of positive LA screening test results.

    “In contrast, using mixing tests interpreted with ICA demonstrates superior specificity as there are few false positives of inhibition by non-LA causes in cases of positive LA screening test results [16].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 30 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Kumano, O., & Moore, G. W.
Affiliations
  • Sysmex (Japan) (JP)
  • St Thomas' Hospital (GB)
Corresponding author
Kumano, Osamu
Venue
Research and Practice in Thrombosis and Haemostasis
Publisher
Elsevier BV
Published
2019-10
Volume
3
Issue
4
Pages
695-703
ISSN
2475-0379 (ISSN-L)
OpenAlex
W2966541221
Cited by
24
References
30
Citations by year
2026: 2 · 2025: 2 · 2024: 7 · 2023: 4 · 2022: 2 · 2021: 3 · 2019: 3 · 2017: 1
FWCI
1.52
Type
journal article
Language
en
Open access
Locations
  • Research and Practice in Thrombosis and Haemostasis (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Hematology › Hemophilia Treatment and Research
Keywords
lupus anticoagulant, mixing test, antiphospholipid syndrome, activated partial thromboplastin time, factor deficiency, warfarin, coagulation factor inhibitors, rivaroxaban, apixaban, prolonged clotting time, specificity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review