Index of circulating anticoagulant cut‐off value establishment in activated partial thromboplastin time mixing test for lupus anticoagulant diagnosis
Open accessIntegrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Cut-off values for screen, confirm, and mixing test in each additional reagent were determined from upper limits of the distribution of 50 normal samples in each reagent.
“Cut‐off values for screen, confirm, and mixing test in each additional reagent were determined from upper limits of the distribution of 50 normal samples in each reagent, and for ICA with the routinely employed LA reagents, ICA cut‐off values were previously established and used in each additional reagent.9, 21, 22, 23”
Cites
Brandt, J. T., Barna, L. K., & Triplett, D. A. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1649988 · Cited by 231 · see citing works
Detection and Quantitative Evaluation of Lupus Circulating Anticoagulant Activity
Rosner, E., Pauzner, R., Lusky, A., Modan, M., & Many, A. (1987) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1651083 · Cited by 188 · see citing works
RUFFATTI, A., OLIVIERI, S., TONELLO, M., BORTOLATI, M., BISON, E., SALVAN, E., FACCHINETTI, M., & PENGO, V. (2008) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2008.03121.x · Cited by 134 · see citing works
The sensitivity of different coagulation reagents to the presence of lupus anticoagulants
(1986) · Thrombosis Research · doi:10.1016/0049-3848(86)91499-4 · Cited by 74 · see citing works
KUMANO, O., IEKO, M., NAITO, S., YOSHIDA, M., & TAKAHASHI, N. (2012) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2012.04906.x · Cited by 59 · see citing works
Self-citationSensitivity of Sixteen APTT Reagents for the Presence of Lupus Anticoagulants
Denis-Magdelaine, A., Flahault, A., & Verdy, E. (2009) · Haemostasis · doi:10.1159/000217148 · Cited by 40 · see citing works
Clinical significance of the mixing test in laboratory diagnoses of lupus anticoagulant
Hong, S. K., Hwang, S. M., Kim, J.-E., & Kim, H. K. (2012) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e328358e899 · Cited by 22 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Recent Guidelines and Recommendations for Laboratory Detection of Lupus Anticoagulants
Moore, G. (2014) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1364185 · Cited by 148 · see citing works
“53,54”
Moore, G. W., Culhane, A. P., Daw, C. R., Noronha, C. P., & Kumano, O. (2016) · Thrombosis Research · doi:10.1016/j.thromres.2016.01.019 · Cited by 42 · see citing works
Current Controversies in Lupus Anticoagulant Detection
Moore, G. (2016) · Antibodies · doi:10.3390/antib5040022 · Cited by 36 · see citing works
Kumano, O., & Moore, G. W. (2018) · Research and Practice in Thrombosis and Haemostasis · doi:10.1002/rth2.12069 · Cited by 26 · see citing works
Self-citationKumano, O., Ieko, M., Naito, S., Yoshida, M., Takahashi, N., Suzuki, T., & Aoki, T. (2014) · Thrombosis Research · doi:10.1016/j.thromres.2014.05.030 · Cited by 15 · see citing works
Self-citationAnalytical dilemmas in lupus anticoagulant detection
Moore, G. W. (2023) · Exploration of Immunology · doi:10.37349/ei.2023.00104 · Cited by 5 · see citing works
- Authors
- Kumano, O., Ieko, M., Naito, S., Yoshida, M., Takahashi, N., & Aoki, T.
- Affiliations
- Health Sciences University of Hokkaido (JP)
- Corresponding author
- Ieko, M.
- Venue
- Journal of Thrombosis and Haemostasis
- Publisher
- Elsevier BV
- Published
- 2013-10
- Volume
- 11
- Issue
- 10
- Pages
- 1919-1922
- ISSN
- 1538-7836 (ISSN-L)
- OpenAlex
- W1526218202
- Cited by
- 14
- References
- 7
- Citations by year
- 2026: 1 · 2023: 2 · 2022: 2 · 2018: 2 · 2017: 2 · 2016: 3 · 2014: 2
- Type
- paratext
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Thrombosis and Haemostasis (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Health Sciences › Medicine › Surgery › Heparin-Induced Thrombocytopenia and Thrombosis
- Keywords
- lupus anticoagulant, activated partial thromboplastin time, mixing test, antiphospholipid antibodies, anticoagulant screening
- MeSH terms
- Anticoagulants, Autoimmune Diseases, Humans, Partial Thromboplastin Time, Lupus Coagulation Inhibitor, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review