Reproducibility of Measures of Visit-to-Visit Variability in Blood Pressure after Transient Ischaemic Attack or Minor Stroke
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: In certain patients in routine practice, blood pressure (BP) measurements differ substantially from week to week or month to month. Although often assumed to be random, such variability could provide information on underlying pathology or prognosis. In order to be informative, however, visit-to-visit BP variability would have to be neither random (i.e. it should be reproducible over time within individuals) nor artefactual (i.e. it should not be an artefact of the method/timing of measurement, for example). Methods: We quantified visit-to-visit variability in BP and explored potential confounding factors by analysing repeat measurements obtained every few months during follow-up in two large trials in patients with a transient ischaemic attack (TIA) or minor ischaemic stroke: the UK-TIA Aspirin Trial (effect of aspirin, effect of season and day of the week of measurement) and the European Carotid Surgery Trial (ECST – effect of carotid endarterectomy). By comparing different periods of follow-up, we also determined the reproducibilities of mean and several different measures of variability for both systolic (SBP) and diastolic BP (DBP). Results: The mean absolute difference between adjacent SBP readings was 14.7 mm Hg in the UK-TIA Trial and 16.0 mm Hg in ECST. Visit-to-visit variability in both SBP and DBP were independent of the potentially confounding factors studied, but reproducibility of all the variability measures was statistically significantly greater than zero. Reproducibility (intraclass correlation) of standard deviation of SBP was 0.32 (p < 0.0001) in the UK-TIA Trial and 0.18 (p = 0.0007) in ECST. Consequently, classification of patients with high (top quintile) or low (bottom quintile) variability was consistent over time (observed/expected = 2.21, 95% confidence interval 1.71–2.85, p < 0.0001, and 1.65, 1.23–2.21, p = 0.0007, respectively). Reproducibility increased with the number of measurements used to calculate variability, and was independent of any correlation with mean BP. Conclusions: Visit-to-visit variability in BP in these populations was reproducible, independently of any correlation with mean BP, demonstrating that visit-to-visit intra-individual BP variability is not random.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903 · cited 1×
“These data therefore also allowed a comparison of visit-to-visit variability in BP between those randomised to aspirin and those in the placebo group. Randomisation to CEA. In ECST, we compared visit-to-visit variability in those patients randomised to CEA versus those randomised to medical treatment. Further, amongst…”
MethodFleiss, J. L., & Cohen, J. (1973) · Educational and Psychological Measurement · doi:10.1177/001316447303300309 · Cited by 3,354
Cited by
Rothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Sever, P. S., & Poulter, N. R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60308-x · Cited by 1,784
Self-citationRothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Poulter, N. R., & Sever, P. S. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70066-1 · Cited by 690
Self-citationMuntner, P., Shimbo, D., Tonelli, M., Reynolds, K., Arnett, D. K., & Oparil, S. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.162255 · Cited by 440
Gosmanova, E. O., Mikkelsen, M. K., Molnar, M. Z., Lu, J. L., Yessayan, L. T., Kalantar-Zadeh, K., & Kovesdy, C. P. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.06.054 · Cited by 293
Manning, L., Hirakawa, Y., Arima, H., Wang, X., Chalmers, J., Wang, J., Lindley, R., Heeley, E., Delcourt, C., Neal, B., et al. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70018-3 · Cited by 273
Self-citationParati, G., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Castiglioni, P., Stergiou, G. S., Mancia, G., Asayama, K., Asmar, R., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003363 · Cited by 220
Shimbo, D., Newman, J. D., Aragaki, A. K., LaMonte, M. J., Bavry, A. A., Allison, M., Manson, J. E., & Wassertheil-Smoller, S. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.193094 · Cited by 188
“reproducibility of VVV of blood pressure may also increase with more measurements.(15,16) Therefore, for evaluating an”
Wang, J., Shi, X., Ma, C., Zheng, H., Xiao, J., Bian, H., Ma, Z., & Gong, L. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001159 · Cited by 162
“Studies indicated that VVV of BP can be reproduced accurately in patients after TIA or minor stroke without random [25] and that long-term VVV of clinic SBP has been shown strong associations with cardiovascular outcomes [10,26,27].”
BackgroundNagai, M., Hoshide, S., Ishikawa, J., Shimada, K., & Kario, K. (2011) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2011.03.001 · Cited by 161
Maximum Value of Home Blood Pressure: A Novel Indicator of Target Organ Damage in Hypertension
Matsui, Y., Ishikawa, J., Eguchi, K., Shibasaki, S., Shimada, K., & Kario, K. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.171645 · Cited by 127
Liddle, L., Burleigh, M. C., Monaghan, C., Muggeridge, D. J., Sculthorpe, N., Pedlar, C. R., Butcher, J., Henriquez, F. L., & Easton, C. (2019) · Nitric Oxide · doi:10.1016/j.niox.2018.12.003 · Cited by 59
“In absolute terms, baseline systolic blood pressure (mean 126 ± 7 mmHg) varied by 2.5 mmHg across the three trials of the present study compared to 14.7 mmHg (mean 147 ± 18.4 mmHg) in patients who had suffered a minor transient ischemic attach or minor ischemic stroke (Howard and Rothwell 2009).”
Influential
Metadata
- Authors
- Howard, S. C., & Rothwell, P. M.
- Venue
- Cerebrovascular Diseases
- Publisher
- S. Karger AG
- Published
- 2009
- Volume
- 28
- Issue
- 4
- Pages
- 331-340
- ISSN
- 1015-9770 (ISSN-L)
- 1421-9786
- OpenAlex
- W2071379215
- Cited by
- 97
- References
- 3
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.