CoChat

The Longest Wheal Diameter Is the Optimal Measurement for the Evaluation of Skin Prick Tests

Open access
Konstantinou, George N., Bousquet, Philippe-Jean, Zuberbier, Torsten, Papadopoulos, Nikolaos G. · 2010 · International Archives of Allergy and Immunology
Cited by 69

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Mean diameter or longest diameter are the 2 most frequently used parameters for wheal response assessment after skin prick testing (SPT). We aimed to compare these 2 parameters taking as gold standard the surface of the wheal skin response. Patients and Methods: Patients suspected of having an allergic reaction against inhalant allergens have been skin prick tested using the Pan-European GA 2 LEN SPT panel. Fifteen minutes later, macroscopically evident wheal and flare reactions were marked with a pen and transferred to paper with a transparent scotch tape. Each paper-transferred wheal was scanned with an ordinary scanner, and its surface-corresponding maximum perpendicular diameters and longest diameters were measured using a computer software application for image recognition, developed for this purpose. Correlation coefficients (Spearman’s ρ) between surfaces and respective mean (ρ mean) or longest (ρ longest) diameters were calculated and subsequently compared. Results: 1,554 SPTs were performed in 74 patients. In 264, a macroscopically evident wheal and flare response was observed. Both mean and longest diameters correlated significantly with the wheal surfaces. However, ρ longest was statistically significantly larger than ρ mean when the surface of the wheal was >17 mm 2 (ρ longest > 0.860 vs. ρ mean < 0.660; p < 0.05).Such a surface corresponds to a maximum diameter of approximately 7 mm and a mean diameter of approximately 6 mm. Thus, the larger the surface of the wheal, the more appropriate the usage of the longest diameter. Conclusions: The longest wheal diameter alone seems to be a better surrogate marker of the wheal surface in comparison with the mean diameter. In addition, it is easier and faster to measure. Therefore, we propose this as the optimal methodology to evaluate SPTs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000250443

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 69

Metadata

Authors
Konstantinou, G. N., Bousquet, P.-J., Zuberbier, T., & Papadopoulos, N. G.
Venue
International Archives of Allergy and Immunology
Publisher
S. Karger AG
Published
2009-10-22
Volume
151
Issue
4
Pages
343-345
ISSN
  • 1018-2438 (ISSN-L)
  • 1423-0097
OpenAlex
W2025798019
Cited by
69
References
1
FWCI
0.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Longest Wheal Diameter Is the Optimal Measurement for the Evaluation of Skin Prick Tests. https://app.cochat.ai/papers/10.1159/000250443
The paper
Konstantinou, G. N., Bousquet, P.-J., Zuberbier, T., & Papadopoulos, N. G. (2010). The Longest Wheal Diameter Is the Optimal Measurement for the Evaluation of Skin Prick Tests. International Archives of Allergy and Immunology. https://doi.org/10.1159/000250443

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.