Oral Appliance Therapy versus Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea: A Randomized, Placebo-Controlled Trial

Aarab, Ghizlane, Lobbezoo, Frank, Hamburger, Hans L., Naeije, Machiel · 2011 · Respiration

Abstract

Background: Previous randomized controlled trials have addressed the efficacy of mandibular advancement devices (MADs) in the treatment of obstructive sleep apnea (OSA). Their common control condition, nasal continuous positive airway pressure (nCPAP), was frequently found to be superior to MAD therapy. However, in most of these studies, only nCPAP was titrated objectively but not MAD. To enable an unbiased comparison between both treatment modalities, the MAD should be titrated objectively as well. Objective: The aim of the present study was to compare the treatment effects of a titrated MAD with those of nCPAP and an intra-oral placebo device. Methods: Sixty-four mild/moderate patients with obstructive sleep apnea (OSA; 52.0 ± 9.6 years) were randomly assigned to three parallel groups: MAD, nCPAP and placebo device. From all patients, two polysomnographic recordings were obtained at the hospital: one before treatment and one after approximately 6 months of treatment. Results: The change in the apnea-hypopnea index (ΔAHI) between baseline and therapy evaluation differed significantly between the three therapy groups (ANCOVA; p = 0.000). No differences in the ΔAHI were found between the MAD and nCPAP therapy (p = 0.092), whereas the changes in AHI in these groups were significantly larger than those in the placebo group (p = 0.000 and 0.002, respectively). Conclusion: There is no clinically relevant difference between MAD and nCPAP in the treatment of mild/moderate OSA when both treatment modalities are titrated objectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000319595

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 172

Metadata

Authors
Aarab, G., Lobbezoo, F., Hamburger, H. L., & Naeije, M.
Venue
Respiration
Publisher
S. Karger AG
Published
2010-10-20
Volume
81
Issue
5
Pages
411-419
ISSN
  • 0025-7931 (ISSN-L)
  • 1423-0356
OpenAlex
W2171318968
Cited by
172
References
12
FWCI
3.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oral Appliance Therapy versus Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea: A Randomized, Placebo-Controlled Trial. https://app.cochat.ai/papers/10.1159/000319595
The paper
Aarab, G., Lobbezoo, F., Hamburger, H. L., & Naeije, M. (2011). Oral Appliance Therapy versus Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea: A Randomized, Placebo-Controlled Trial. Respiration. https://doi.org/10.1159/000319595

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.