The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sensitivity of Blood Volume Monitoring for Fluid Status Assessment in Hemodialysis Patients
Open accessAbstract
Background/Aims: This study investigates the use of blood volume monitoring (BVM) markers for the assessment of fluid status. Methods: Predialysis fluid overload (FO) and BVM data were collected in 55 chronic hemodialysis patients in 317 treatments. Predialysis FO was measured using bioimpedance spectroscopy. The slope of the intravascular volume decrease over time normalized by ultrafiltration rate (Slope4h) was used as the primary BVM marker and compared against FO. Results: Average relative blood volume curves were well separated in different FO groups between 0 and 5 liters. Receiver-operating characteristics analysis revealed that the sensitivity of BVM was moderate in median FO ranges between 1 and 3 liters (AUC 0.60-0.65), slightly higher for volume depletion of FO <1 liter (AUC 0.7) and highest for excess fluid of FO >3 liters (AUC 0.85). Conclusion: Devices that monitor blood volume are well suited to detect high FO, but are not as sensitive at moderate or low levels of fluid status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Cited by
Assessment methods in human body composition
Lee, S. Y., & Gallagher, D. (2008) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e32830b5f23 · Cited by 694
Importance of Whole-Body Bioimpedance Spectroscopy for the Management of Fluid Balance
Wabel, P., Chamney, P., Moissl, U., & Jirka, T. (2009) · Blood Purification · doi:10.1159/000167013 · Cited by 375
Skin Sodium Concentration Correlates with Left Ventricular Hypertrophy in CKD
Schneider, M. P., Raff, U., Kopp, C., Scheppach, J. B., Toncar, S., Wanner, C., Schlieper, G., Saritas, T., Floege, J., Schmid, M., et al. (2017) · Journal of the American Society of Nephrology · doi:10.1681/asn.2016060662 · Cited by 195
Heymsfield, S. B., Ebbeling, C. B., Zheng, J., Pietrobelli, A., Strauss, B. J., Silva, A. M., & Ludwig, D. S. (2015) · Obesity Reviews · doi:10.1111/obr.12261 · Cited by 111
Limitations of Fat-Free Mass for the Assessment of Muscle Mass in Obesity
Jensen, B., Braun, W., Geisler, C., Both, M., Klückmann, K., Müller, M. J., & Bosy-Westphal, A. (2019) · Obesity Facts · doi:10.1159/000499607 · Cited by 105
Metadata
- Authors
- Maduell, F., Arias, M., Massó, E., Fontseré, N., Carrera, M., Vera, M., Cases, A., & Campistol, J. M.
- Venue
- Blood Purification
- Publisher
- S. Karger AG
- Published
- 2013
- Volume
- 35
- Issue
- 1-3
- Pages
- 202-208
- ISSN
- 0253-5068 (ISSN-L)
- 1421-9735
- OpenAlex
- W2157893516
- Cited by
- 368
- References
- 1
- FWCI
- 18.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity of Blood Volume Monitoring for Fluid Status Assessment in Hemodialysis Patients. https://app.cochat.ai/papers/10.1159/000346630
- The paper
- Maduell, F., Arias, M., Massó, E., Fontseré, N., Carrera, M., Vera, M., Cases, A., & Campistol, J. M. (2013). Sensitivity of Blood Volume Monitoring for Fluid Status Assessment in Hemodialysis Patients. Blood Purification. https://doi.org/10.1159/000346630
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.