Limitations of Fat-Free Mass for the Assessment of Muscle Mass in Obesity
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background: A high amount of adipose tissue limits the accuracy of methods for body composition analysis in obesity. Objectives: The aim was to quantify and explain differences in fat-free mass (FFM) (as an index of skeletal muscle mass, SMM) measured with bioelectrical impedance analysis (BIA), dual energy X-ray absorptiometry (DXA), air displacement plethysmography (ADP), and deuterium dilution in comparison to multicompartment models, and to improve the results of BIA for obese subjects. Methods: In 175 healthy subjects (87 men and 88 women, BMI 20–43.3 kg/m 2, 18–65 years), FFM measured by these methods was compared with results from a 3- (3C) and a 4-compartment (4C) model. FFM 4C was compared with SMM measured by magnetic resonance imaging. Results: BIA and DXA overestimated and ADP underestimated FFM in comparison to 3C and 4C models with increasing BMI (all p < 0.001). Differences were largest for DXA. In obesity, BIA results were improved: value corrected = value uncorrected – a(BMI – 30 kg/m 2), a = 0.256 for FFM and a = 0.298 for SMM. SMM accounts for 45% of FFM in women and 49% in men. Conclusions: In obesity, the use of FFM is limited by a systematic error of reference methods. In addition, SMM accounts for about 50% of FFM only. Corrected measurement of SMM by BIA can overcome these drawbacks.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In turn, BIA limitations also include lack of direct measurement of body composition. Skeletal muscle mass is estimated based on BIA raw measurements based on population and device speci fi c equations, with reduced accuracy in the presence of altered fl uid balance. The presence of obesity specially impacts the assumption of constant hydration potentially decreasing BIA accuracy [121,122].”
From Definition and diagnostic criteria for sarcopenic obesity: ESPEN and EASO consensus statement (2022) · cites this paper as [122]
In the citing paper
“Moreover, using BIA in individuals with BMI > 34 kg/m 2 may lead to an underestimation of FM and an overestimation of FFM [117].”
From Definition and Diagnostic Criteria for Sarcopenic Obesity: ESPEN and EASO Consensus Statement (2022) · cites this paper as [117]
Citations
Cites
Sarcopenia: European consensus on definition and diagnosis
Cruz-Jentoft, A. J., Baeyens, J. P., Bauer, J. M., Boirie, Y., Cederholm, T., Landi, F., Martin, F. C., Michel, J.-P., Rolland, Y., Schneider, S. M., et al. (2010) · Age and Ageing · doi:10.1093/ageing/afq034 · Cited by 11,601
Prado, C. M., Lieffers, J. R., McCargar, L. J., Reiman, T., Sawyer, M. B., Martin, L., & Baracos, V. E. (2008) · The Lancet Oncology · doi:10.1016/s1470-2045(08)70153-0 · Cited by 3,238
Body composition from fluid spaces and density: analysis of methods. 1961.
Siri, W. E. (1993) · PubMed · Cited by 2,573
Understanding the mechanisms and treatment options in cancer cachexia
Fearon, K., Arends, J., & Baracos, V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.209 · Cited by 940
Human Body Composition: In Vivo Methods
Ellis, K. J. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.649 · Cited by 825
Fat-free mass index and fat mass index percentiles in Caucasians aged 18–98 y
Schutz, Y., Kyle, U., & Pichard, C. (2002) · International Journal of Obesity · doi:10.1038/sj.ijo.0802037 · Cited by 670
Body composition estimates from NHANES III bioelectrical impedance data
Chumlea, W., Guo, S., Kuczmarski, R., Flegal, K., Johnson, C., Heymsfield, S., Lukaski, H., Friedl, K., & Hubbard, V. (2002) · International Journal of Obesity · doi:10.1038/sj.ijo.0802167 · Cited by 507
Fuller, N. J., Jebb, S. A., Laskey, M. A., Coward, W. A., & Elia, M. (1992) · Clinical Science · doi:10.1042/cs0820687 · Cited by 396
Sensitivity of Blood Volume Monitoring for Fluid Status Assessment in Hemodialysis Patients
Maduell, F., Arias, M., Massó, E., Fontseré, N., Carrera, M., Vera, M., Cases, A., & Campistol, J. M. (2013) · Blood Purification · doi:10.1159/000346630 · Cited by 368
Hydration of fat-free body mass: review and critique of a classic body-composition constant
Wang, Z., Deurenberg, P., Wang, W., Pietrobelli, A., Baumgartner, R. N., & Heymsfield, S. B. (1999) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/69.5.833 · Cited by 345
Cited by
Definition and Diagnostic Criteria for Sarcopenic Obesity: ESPEN and EASO Consensus Statement
Donini, L. M., Busetto, L., Bischoff, S. C., Cederholm, T., Ballesteros-Pomar, M. D., Batsis, J. A., Bauer, J. M., Boirie, Y., Cruz-Jentoft, A. J., Dicker, D., et al. (2022) · Obesity Facts · doi:10.1159/000521241 · Cited by 1,019
Definition and diagnostic criteria for sarcopenic obesity: ESPEN and EASO consensus statement
Donini, L. M., Busetto, L., Bischoff, S. C., Cederholm, T., Ballesteros-Pomar, M. D., Batsis, J. A., Bauer, J. M., Boirie, Y., Cruz-Jentoft, A. J., Dicker, D., et al. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2021.11.014 · Cited by 566
“The presence of obesity specially impacts the assumption of constant hydration potentially decreasing BIA accuracy [121, 122].”
Nuzzo, J. L. (2023) · Journal of Strength & Conditioning Research · doi:10.1519/jsc.0000000000004329 · Cited by 304
Reference Values for Skeletal Muscle Mass – Current Concepts and Methodological Considerations
Walowski, C. O., Braun, W., Maisch, M. J., Jensen, B., Peine, S., Norman, K., Müller, M. J., & Bosy-Westphal, A. (2020) · Nutrients · doi:10.3390/nu12030755 · Cited by 200
Self-citationThe GLIM consensus approach to diagnosis of malnutrition: A 5-year update
Cederholm, T., Jensen, G. L., Correia, M. I. T. D., González, M. C., Fukushima, R., Pisprasert, V., Blaauw, R., Cárdenas, D., Carrasco, F., Cruz-Jentoft, A. J., et al. (2025) · Clinical Nutrition · doi:10.1016/j.clnu.2025.03.018 · Cited by 122
“DXA and BIA with population-speci fi c equations are also options for muscle mass assessment in subjects with obesity that is not severe [45].”
Metadata
- Authors
- Jensen, B., Braun, W., Geisler, C., Both, M., Klückmann, K., Müller, M. J., & Bosy-Westphal, A.
- Affiliations
- Christian-Albrechts-Universität zu Kiel (DE)
- University Hospital Schleswig-Holstein (DE)
- Venue
- Obesity Facts
- Publisher
- S. Karger AG
- Published
- 2019
- Volume
- 12
- Issue
- 3
- Pages
- 307-315
- ISSN
- 1662-4025 (ISSN-L)
- 1662-4033
- PMC
- PMC6696776
- OpenAlex
- W2946992738
- Cited by
- 105
- References
- 25
- Citations by year
- 2026: 17 · 2025: 24 · 2024: 6 · 2023: 13 · 2022: 16 · 2021: 13 · 2020: 16
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
- creativecommons.org/licenses/by-nc-nd/4.0/ (tdm)
- Locations
- Obesity Facts (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Health Sciences › Medicine › Physiology (medical) › Nutrition and Health in Aging
- Health Sciences › Nursing › Nutrition and Dietetics › Muscle metabolism and nutrition
- Keywords
- fat-free mass, skeletal muscle mass, obesity, body composition assessment, bioelectrical impedance analysis, dual-energy X-ray absorptiometry, air displacement plethysmography, deuterium dilution, multi-compartment model, measurement error correction, adipose tissue
- MeSH terms
- Adipose Tissue, Adolescent, Adult, Aged, Body Composition, Body Weights and Measures, Female, Humans, Male, Middle Aged, Obesity, Organ Size, Plethysmography, Reproducibility of Results, Absorptiometry, Photon, Electric Impedance, Muscle, Skeletal, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limitations of Fat-Free Mass for the Assessment of Muscle Mass in Obesity. https://app.cochat.ai/papers/10.1159/000499607
- The paper
- Jensen, B., Braun, W., Geisler, C., Both, M., Klückmann, K., Müller, M. J., & Bosy-Westphal, A. (2019). Limitations of Fat-Free Mass for the Assessment of Muscle Mass in Obesity. Obesity Facts. https://doi.org/10.1159/000499607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.