Aneurysm Study of Pipeline in an Observational Registry (ASPIRe)
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Background and Objective: Few prospective studies exist evaluating the safety and efficacy of the Pipeline Embolization Device (PED) in the treatment of intracranial aneurysms. The Aneurysm Study of Pipeline In an observational Registry (ASPIRe) study prospectively analyzed rates of complete aneurysm occlusion and neurologic adverse events following PED treatment of intracranial aneurysms. Materials and Methods: We performed a multicenter study prospectively evaluating patients with unruptured intracranial aneurysms treated with PED. Primary outcomes included (1) spontaneous rupture of the Pipeline-treated aneurysm; (2) spontaneous nonaneurysmal intracranial hemorrhage (ICH); (3) acute ischemic stroke; (4) parent artery stenosis, and (5) permanent cranial neuropathy. Secondary endpoints were (1) treatment success and (2) morbidity and mortality at the 6-month follow-up. Vascular imaging was evaluated at an independent core laboratory. Results: One hundred and ninety-one patients with 207 treated aneurysms were included in this registry. The mean aneurysm size was 14.5 ± 6.9 mm, and the median imaging follow-up was 7.8 months. Twenty-four aneurysms (11.6%) were small, 162 (78.3%) were large and 21 (10.1%) were giant. The median clinical follow-up time was 6.2 months. The neurological morbidity rate was 6.8% (13/191), and the neurological mortality rate was 1.6% (3/191). The combined neurological morbidity/mortality rate was 6.8% (13/191). The most common adverse events were ischemic stroke (4.7%, 9/191) and spontaneous ICH (3.7%, 7/191). The complete occlusion rate at the last follow-up was 74.8% (77/103). Conclusions: Our prospective postmarket study confirms that PED treatment of aneurysms in a heterogeneous patient population is safe with low rates of neurological morbidity and mortality. Patients with angiographic follow-up had complete occlusion rates of 75% at 8 months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial
Becske, T., Kallmes, D. F., Saatci, I., McDougall, C. G., Szikora, I., Lanzino, G., Moran, C. J., Woo, H. H., Lopes, D. K., Berez, A. L., et al. (2013) · Radiology · doi:10.1148/radiol.13120099 · Cited by 1,108
Self-citationEndovascular Treatment of Intracranial Aneurysms With Flow Diverters: A Meta-Analysis
Brinjikji, W., Murad, M. H., Lanzino, G., Cloft, H. J., & Kallmes, D. F. (2013) · Stroke · doi:10.1161/strokeaha.112.678151 · Cited by 900
Self-citationThe Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
Nelson, P. K., Lylyk, P., Szikora, I., Wetzel, S. G., Wanke, I., & Fiorella, D. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2421 · Cited by 843
Self-citationSaatci, I., Yavuz, K., Ozer, C., Geyik, S., & Cekirge, H. S. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3246 · Cited by 368
Turowski, B., Macht, S., Kulcsár, Z., Hänggi, D., & Stummer, W. (2011) · Neuroradiology · doi:10.1007/s00234-010-0676-7 · Cited by 227
Cruz, J. P., Chow, M., O'Kelly, C. J., Marotta, B., Spears, J., Montanera, W. J., Fiorella, D. J., & Marotta, T. R. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3065 · Cited by 186
Self-citationFlow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis
Arrese, I., Sarabia, R., Pintado, R., & Delgado-Rodriguez, M. (2013) · Neurosurgery · doi:10.1227/01.neu.0000430297.17961.f1 · Cited by 171
Hong, Y., Wang, Y., Deng, Z., Wu, Q., & Zhang, J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0082311 · Cited by 143
Coiling of Large and Giant Aneurysms: Complications and Long-Term Results of 334 Cases
Chalouhi, N., Tjoumakaris, S., Gonzalez, L. F., Dumont, A. S., Starke, R. M., Hasan, D. M., Wu, C., Singhal, S., Moukarzel, L. A., Rosenwasser, R. H., et al. (2013) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3696 · Cited by 138
Self-citationTurfe, Z. A., Brinjikji, W., Murad, M. H., Lanzino, G. S., Cloft, H. J., & Kallmes, D. F. (2014) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2014-011102 · Cited by 41
Self-citation
Cited by
Cagnazzo, F., di Carlo, D. T., Cappucci, M., Lefevre, P.-H., Costalat, V., & Perrini, P. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5730 · Cited by 175
Sarrami-Foroushani, A., Lassila, T., MacRaild, M., Asquith, J., Roes, K. C. B., Byrne, J. V., & Frangi, A. F. (2021) · Nature Communications · doi:10.1038/s41467-021-23998-w · Cited by 83
Metadata
- Authors
- Kallmes, D. F., Brinjikji, W., Boccardi, E., Ciceri, E., Diaz, O., Tawk, R., Woo, H., Jabbour, P., Albuquerque, F., Chapot, R., Bonafe, A., Dashti, S. R., Delgado Almandoz, J. E., Given II, C., Kelly, M. E., Cross III, D. T., Duckwiler, G., Razack, N., Powers, C. J., Fischer, S., Lopes, D., Harrigan, M. R., Huddle, D., Turner IV, R., Zaidat, O. O., Defreyne, L., Mendes Pereira, V., Cekirge, S., Fiorella, D., Hanel, R. A., Lylyk, P., McDougall, C., Siddiqui, A., Szikora, I., & Levy, E.
- Venue
- Interventional Neurology
- Publisher
- S. Karger AG
- Published
- 2016
- Volume
- 5
- Issue
- 1-2
- Pages
- 89-99
- ISSN
- 1664-5545 (ISSN-L)
- 1664-9737
- OpenAlex
- W2405525159
- Cited by
- 210
- References
- 11
- FWCI
- 16.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aneurysm Study of Pipeline in an Observational Registry (ASPIRe). https://app.cochat.ai/papers/10.1159/000446503
- The paper
- Kallmes, D. F., Brinjikji, W., Boccardi, E., Ciceri, E., Diaz, O., Tawk, R., Woo, H., Jabbour, P., Albuquerque, F., Chapot, R., Bonafe, A., Dashti, S. R., Delgado Almandoz, J. E., Given II, C., Kelly, M. E., Cross III, D. T., Duckwiler, G., Razack, N., Powers, C. J., . . . Levy, E. (2016). Aneurysm Study of Pipeline in an Observational Registry (ASPIRe). Interventional Neurology. https://doi.org/10.1159/000446503
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.